On the feasibility of absolute 3D dosimetry using LiF thermoluminescence detectors and polymer gels on a 0.35T MR-LINAC

Background and Purpose. As shown in our previous study, highly accurate absolute dosimetry in 3D is feasible by combining polymer gels (PG) with thermoluminescence dosimetry (TLD). In this setup, the thermoluminescence (TL)-based point dose information is used to renormalize the PG. This new PG-TLD...

Full description

Saved in:
Bibliographic Details
Main Authors: Schwahofer, Andrea (Author) , Mann, Philipp (Author) , Renkamp, Claudia Katharina (Author) , Karger, Christian (Author)
Format: Article (Journal)
Language:English
Published: 19 October 2020
In: Physics in medicine and biology
Year: 2020, Volume: 65, Issue: 21
ISSN:1361-6560
DOI:10.1088/1361-6560/aba6d7
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1088/1361-6560/aba6d7
Get full text
Author Notes:A. Schwahofer, P. Mann, C.K. Spindeldreier and C.P. Karger
Description
Summary:Background and Purpose. As shown in our previous study, highly accurate absolute dosimetry in 3D is feasible by combining polymer gels (PG) with thermoluminescence dosimetry (TLD). In this setup, the thermoluminescence (TL)-based point dose information is used to renormalize the PG. This new PG-TLD reference system is now extended to measurements in magnetic fields. Materials and Methods. Experiments were carried out on a conventional 6 MV linear accelerator (LINAC) and a 6 MV 0.35 T magnetic resonance (MR)-LINAC. Signal stability of TLD600 and TLD700 was examined without and with magnetic field. Afterwards, the combination of PAGAT PG and TL detectors was employed within a cylindrical phantom in presence of the magnetic field. Two scenarios were tested: (I) an air-filled phantom and (II) a water-filled phantom. For each scenario, two plans were irradiated: (a) opposed beams with a field size of 10 × 10 cm2 and (b) a 3D conformal plan assuring homogeneous target coverage using three equally distributed coplanar beams. Results. Mean relative uncertainty of TL calibration reproducibility for TLD600/TLD700 was 0.49%/0.85% at the MR-LINAC and 0.48%/0.83% for the conventional LINAC. Individual TL calibration coefficients of TLD600 and TLD700 behaved differently in the presence of the magnetic field. An average difference of (3.29 ± 0.89)% occurred for all TLD600, whereas the result for TLD700 is not quite as clear with (1.09 ± 0.89)% after excluding some outliers. Using the TL dose information for PG renormalization, high 3D gamma passing rates were achieved using the 3%/2 mm criteria: 91.0% (Ia), 92.6% (Ib), 94.3% (IIa), 97.4% (IIb). Conclusion. This study shows that TL signal reproducibility is not affected by a low magnetic field. Nevertheless, absolute calibration coefficients of the individual detectors indicate a dependency on the magnetic field. Hence, a calibration at the appropriate LINAC type is recommended. Furthermore, the previously established renormalization method for PG was applied to measurements at a MR-LINAC and was verified as suitable for evaluations of homogeneous dose distribution in the target volume.
Item Description:Gesehen am 24.11.2020