Diagnostic accuracy of 870-nm spectral-domain OCT with enhanced depth imaging for the detection of caries beneath ceramics

Objectives - To evaluate the diagnostic accuracy of optical coherence tomography (OCT) for the non-invasive detection of caries adjacent to ceramic materials. - Methods - Disks made from five ceramic materials (hybrid ceramic, feldspathic ceramic, zirconia-reinforced lithium silicate, lithium disili...

Full description

Saved in:
Bibliographic Details
Main Authors: Trebing, Charlotte Theresa (Author) , Schwindling, Franz Sebastian (Author) , Horsch, Laura (Author) , Trebing, Johannes (Author) , Lux, Christopher J. (Author) , Rammelsberg, Peter (Author) , Şen, Sinan (Author)
Format: Article (Journal)
Language:English
Published: 28 August 2020
In: Journal of dentistry
Year: 2020, Volume: 102
ISSN:1879-176X
DOI:10.1016/j.jdent.2020.103458
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.jdent.2020.103458
Verlag, lizenzpflichtig, Volltext: http://www.sciencedirect.com/science/article/pii/S0300571220302049
Get full text
Author Notes:Charlotte Theresa Trebing, Franz Sebastian Schwindling, Laura Leisner, Johannes Trebing, Christopher J. Lux, Peter Rammelsberg, Sinan Sen

MARC

LEADER 00000caa a2200000 c 4500
001 1745533133
003 DE-627
005 20220819083552.0
007 cr uuu---uuuuu
008 210125s2020 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.jdent.2020.103458  |2 doi 
035 |a (DE-627)1745533133 
035 |a (DE-599)KXP1745533133 
035 |a (OCoLC)1341389230 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Trebing, Charlotte Theresa  |e VerfasserIn  |0 (DE-588)1225686970  |0 (DE-627)1745534075  |4 aut 
245 1 0 |a Diagnostic accuracy of 870-nm spectral-domain OCT with enhanced depth imaging for the detection of caries beneath ceramics  |c Charlotte Theresa Trebing, Franz Sebastian Schwindling, Laura Leisner, Johannes Trebing, Christopher J. Lux, Peter Rammelsberg, Sinan Sen 
246 3 3 |a Diagnostic accuracy of eight hundred seventy-nm spectral-domain OCT with enhanced depth imaging for the detection of caries beneath ceramics 
264 1 |c 28 August 2020 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 25.01.2021 
520 |a Objectives - To evaluate the diagnostic accuracy of optical coherence tomography (OCT) for the non-invasive detection of caries adjacent to ceramic materials. - Methods - Disks made from five ceramic materials (hybrid ceramic, feldspathic ceramic, zirconia-reinforced lithium silicate, lithium disilicate, and high-translucent zirconia) were ground to the recommended material thickness for single crown restorations and laminated with a 100 μm thick layer of one of three adhesive cements. The disks were fixed to extracted human molars with or without carious lesions of one of three standardized sizes. A total of 240 stacks of cross-sectional scans obtained using an 870-nm SD-OCT with enhanced depth imaging (EDI) were presented to five raters. Diagnostic accuracy was determined by rating the teeth beneath the cemented material as carious or healthy. - Results - Carious samples were distinguished from sound teeth with high diagnostic accuracy, even for early stage caries. Sensitivity (SE) and specificity (SP) pooled over all raters and all materials were 0.9 and 0.97, respectively. When analyzing the effect of the ceramic and cement materials on detection rates, high SE and SP values of >0.96 and >0.91, respectively, were recorded for lithium disilicate, zirconia-reinforced lithium silicate, and high-translucent zirconia irrespective of the cement type. For hybrid and feldspathic ceramics, the cement material was found to have a significant effect on caries detection. - Conclusions - Given its high diagnostic accuracy, 870-nm SD-OCT with EDI might be useful for the detection of caries beneath restorative materials. The effect of the prescribed ceramic and cement material on optical penetration depth is substantial. 
650 4 |a Caries 
650 4 |a Ceramic restorations 
650 4 |a Demineralization 
650 4 |a Diagnostic accuracy 
650 4 |a Optical coherence tomography 
700 1 |a Schwindling, Franz Sebastian  |d 1986-  |e VerfasserIn  |0 (DE-588)1036843572  |0 (DE-627)751703613  |0 (DE-576)38697926X  |4 aut 
700 1 |a Horsch, Laura  |d 1991-  |e VerfasserIn  |0 (DE-588)1183802404  |0 (DE-627)1663340625  |4 aut 
700 1 |a Trebing, Johannes  |d 1981-  |e VerfasserIn  |0 (DE-588)1069186457  |0 (DE-627)821501836  |0 (DE-576)428485383  |4 aut 
700 1 |a Lux, Christopher J.  |d 1969-  |e VerfasserIn  |0 (DE-588)121600114  |0 (DE-627)081413815  |0 (DE-576)292792549  |4 aut 
700 1 |a Rammelsberg, Peter  |d 1959-  |e VerfasserIn  |0 (DE-588)122469836  |0 (DE-627)705920836  |0 (DE-576)293285640  |4 aut 
700 1 |a Şen, Sinan  |d 1986-  |e VerfasserIn  |0 (DE-588)1082311049  |0 (DE-627)847302989  |0 (DE-576)455334501  |4 aut 
773 0 8 |i Enthalten in  |t Journal of dentistry  |d Amsterdam [u.a.] : Elsevier Science, 1972  |g 102(2020) Artikel-Nummer 103458, 7 Seiten  |h Online-Ressource  |w (DE-627)320456757  |w (DE-600)2006760-4  |w (DE-576)09101770X  |x 1879-176X  |7 nnas  |a Diagnostic accuracy of 870-nm spectral-domain OCT with enhanced depth imaging for the detection of caries beneath ceramics 
773 1 8 |g volume:102  |g year:2020  |g extent:7  |a Diagnostic accuracy of 870-nm spectral-domain OCT with enhanced depth imaging for the detection of caries beneath ceramics 
856 4 0 |u https://doi.org/10.1016/j.jdent.2020.103458  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u http://www.sciencedirect.com/science/article/pii/S0300571220302049  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20210125 
993 |a Article 
994 |a 2020 
998 |g 1082311049  |a Şen, Sinan  |m 1082311049:Şen, Sinan  |d 910000  |d 910800  |e 910000PS1082311049  |e 910800PS1082311049  |k 0/910000/  |k 1/910000/910800/  |p 7  |y j 
998 |g 122469836  |a Rammelsberg, Peter  |m 122469836:Rammelsberg, Peter  |d 910000  |d 910800  |e 910000PR122469836  |e 910800PR122469836  |k 0/910000/  |k 1/910000/910800/  |p 6 
998 |g 121600114  |a Lux, Christopher J.  |m 121600114:Lux, Christopher J.  |d 910000  |d 910800  |e 910000PL121600114  |e 910800PL121600114  |k 0/910000/  |k 1/910000/910800/  |p 5 
998 |g 1069186457  |a Trebing, Johannes  |m 1069186457:Trebing, Johannes  |d 910000  |d 910100  |e 910000PT1069186457  |e 910100PT1069186457  |k 0/910000/  |k 1/910000/910100/  |p 4 
998 |g 1183802404  |a Horsch, Laura  |m 1183802404:Horsch, Laura  |d 910000  |d 910800  |e 910000PH1183802404  |e 910800PH1183802404  |k 0/910000/  |k 1/910000/910800/  |p 3 
998 |g 1036843572  |a Schwindling, Franz Sebastian  |m 1036843572:Schwindling, Franz Sebastian  |d 50000  |e 50000PS1036843572  |k 0/50000/  |p 2 
998 |g 1225686970  |a Trebing, Charlotte Theresa  |m 1225686970:Trebing, Charlotte Theresa  |d 910000  |d 910800  |e 910000PT1225686970  |e 910800PT1225686970  |k 0/910000/  |k 1/910000/910800/  |p 1  |x j 
999 |a KXP-PPN1745533133  |e 3841778933 
BIB |a Y 
SER |a journal 
JSO |a {"person":[{"family":"Trebing","display":"Trebing, Charlotte Theresa","role":"aut","given":"Charlotte Theresa"},{"family":"Schwindling","display":"Schwindling, Franz Sebastian","role":"aut","given":"Franz Sebastian"},{"family":"Horsch","display":"Horsch, Laura","role":"aut","given":"Laura"},{"role":"aut","given":"Johannes","display":"Trebing, Johannes","family":"Trebing"},{"family":"Lux","display":"Lux, Christopher J.","role":"aut","given":"Christopher J."},{"family":"Rammelsberg","display":"Rammelsberg, Peter","given":"Peter","role":"aut"},{"given":"Sinan","role":"aut","display":"Şen, Sinan","family":"Şen"}],"note":["Gesehen am 25.01.2021"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"origin":[{"dateIssuedKey":"2020","dateIssuedDisp":"28 August 2020"}],"titleAlt":[{"title":"Diagnostic accuracy of eight hundred seventy-nm spectral-domain OCT with enhanced depth imaging for the detection of caries beneath ceramics"}],"title":[{"title":"Diagnostic accuracy of 870-nm spectral-domain OCT with enhanced depth imaging for the detection of caries beneath ceramics","title_sort":"Diagnostic accuracy of 870-nm spectral-domain OCT with enhanced depth imaging for the detection of caries beneath ceramics"}],"language":["eng"],"physDesc":[{"extent":"7 S."}],"name":{"displayForm":["Charlotte Theresa Trebing, Franz Sebastian Schwindling, Laura Leisner, Johannes Trebing, Christopher J. Lux, Peter Rammelsberg, Sinan Sen"]},"recId":"1745533133","id":{"doi":["10.1016/j.jdent.2020.103458"],"eki":["1745533133"]},"relHost":[{"part":{"text":"102(2020) Artikel-Nummer 103458, 7 Seiten","year":"2020","volume":"102","extent":"7"},"note":["Gesehen am 04.05.07"],"origin":[{"publisher":"Elsevier Science","dateIssuedKey":"1972","dateIssuedDisp":"1972-","publisherPlace":"Amsterdam [u.a.]"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"title":[{"title":"Journal of dentistry","title_sort":"Journal of dentistry"}],"language":["eng"],"disp":"Diagnostic accuracy of 870-nm spectral-domain OCT with enhanced depth imaging for the detection of caries beneath ceramicsJournal of dentistry","id":{"zdb":["2006760-4"],"eki":["320456757"],"issn":["1879-176X"]},"physDesc":[{"extent":"Online-Ressource"}],"recId":"320456757","pubHistory":["1.1972 -"]}]} 
SRT |a TREBINGCHADIAGNOSTIC2820