Interobserver reliability of automated breast volume scanner (ABVS) interpretation and agreement of ABVS findings with hand held breast ultrasound (HHUS), mammography and pathology results

Objectives - Handheld breast ultrasound (HHUS) lacks standardization and reproducibility. The automated breast volume scanner (ABVS) could overcome this limitation. To analyze the interobserver reliability of ABVS and the agreement with HHUS, mammography and pathology is the aim of this study. - Met...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Golatta, Michael (VerfasserIn) , Franz, Dorothea (VerfasserIn) , Harcos, Aba (VerfasserIn) , Junkermann, Hans (VerfasserIn) , Rauch, Geraldine (VerfasserIn) , Scharf, Alexander (VerfasserIn) , Schütz, Florian (VerfasserIn) , Sohn, Christof (VerfasserIn) , Heil, Jörg (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 27 March 2013
In: European journal of radiology
Year: 2013, Jahrgang: 82, Heft: 8, Pages: e332-e336
ISSN:1872-7727
DOI:10.1016/j.ejrad.2013.03.005
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.ejrad.2013.03.005
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0720048X13001320
Volltext
Verfasserangaben:Michael Golatta, Dorothea Franz, Aba Harcos, Hans Junkermann, Geraldine Rauch, Alexander Scharf, Florian Schuetz, Christof Sohn, Joerg Heil

MARC

LEADER 00000caa a2200000 c 4500
001 1748480022
003 DE-627
005 20220819110726.0
007 cr uuu---uuuuu
008 210217s2013 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.ejrad.2013.03.005  |2 doi 
035 |a (DE-627)1748480022 
035 |a (DE-599)KXP1748480022 
035 |a (OCoLC)1341393532 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Golatta, Michael  |d 1974-  |e VerfasserIn  |0 (DE-588)132350386  |0 (DE-627)521535727  |0 (DE-576)299091392  |4 aut 
245 1 0 |a Interobserver reliability of automated breast volume scanner (ABVS) interpretation and agreement of ABVS findings with hand held breast ultrasound (HHUS), mammography and pathology results  |c Michael Golatta, Dorothea Franz, Aba Harcos, Hans Junkermann, Geraldine Rauch, Alexander Scharf, Florian Schuetz, Christof Sohn, Joerg Heil 
264 1 |c 27 March 2013 
300 |a 5 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 17.02.2020 
520 |a Objectives - Handheld breast ultrasound (HHUS) lacks standardization and reproducibility. The automated breast volume scanner (ABVS) could overcome this limitation. To analyze the interobserver reliability of ABVS and the agreement with HHUS, mammography and pathology is the aim of this study. - Methods - All 42 study participants (=84 breasts) received an ABVS examination in addition to the conventional breast diagnostic work-up. 25 breasts (30%) showed at least one lesion. The scans were interpreted by six breast diagnostic specialists blinded to results of breast imaging and medical history. 32 lesions received histological work-up: 20 cancers were detected. We used kappa statistics to interpret agreement between examiners and diagnostic instruments. - Results - On the basis of the Breast Imaging Reporting and Data System (BI-RADS) classification of the 84 breasts an agreement (defined as ≥4 of 6 examiners) was achieved in 63 cases (75%) (mk=0.35) and even improved when dichotomizing the interpretation in benign (BI-RADS 1, 2) and suspicious (BI-RADS 4, 5) to 98% (mk=0.52). Agreement of ABVS examination to HHUS, mammography and pathology was fair to substantial depending on the specific analysis. - Conclusions - The development of an ABVS seems to be a promising diagnostic method with a good interobserver reliability, as well as a comparable good test criteria as HHUS. 
650 4 |a 3D ultrasound scanning 
650 4 |a Automated breast volume scanner (ABVS) 
650 4 |a BI-RADS 
650 4 |a Breast 
650 4 |a Ultrasound 
700 1 |a Franz, Dorothea  |d 1985-  |e VerfasserIn  |0 (DE-588)1025404556  |0 (DE-627)722218036  |0 (DE-576)37031168X  |4 aut 
700 1 |a Harcos, Aba  |e VerfasserIn  |0 (DE-588)1136396004  |0 (DE-627)892803487  |0 (DE-576)490503594  |4 aut 
700 1 |a Junkermann, Hans  |e VerfasserIn  |0 (DE-588)1032985402  |0 (DE-627)739849565  |0 (DE-576)380461684  |4 aut 
700 1 |a Rauch, Geraldine  |e VerfasserIn  |0 (DE-588)139823492  |0 (DE-627)61378944X  |0 (DE-576)313422923  |4 aut 
700 1 |a Scharf, Alexander  |d 1962-  |e VerfasserIn  |0 (DE-588)131622188  |0 (DE-627)511429975  |0 (DE-576)298631687  |4 aut 
700 1 |a Schütz, Florian  |d 1972-  |e VerfasserIn  |0 (DE-588)12303387X  |0 (DE-627)082307229  |0 (DE-576)293528810  |4 aut 
700 1 |a Sohn, Christof  |d 1961-  |e VerfasserIn  |0 (DE-588)131349287  |0 (DE-627)507642902  |0 (DE-576)298422255  |4 aut 
700 1 |a Heil, Jörg  |d 1978-  |e VerfasserIn  |0 (DE-588)132580187  |0 (DE-627)52396160X  |0 (DE-576)299238679  |4 aut 
773 0 8 |i Enthalten in  |t European journal of radiology  |d Amsterdam [u.a.] : Elsevier Science, 1990  |g 82(2013), 8, Seite e332-e336  |h Online-Ressource  |w (DE-627)32044483X  |w (DE-600)2005350-2  |w (DE-576)099718138  |x 1872-7727  |7 nnas  |a Interobserver reliability of automated breast volume scanner (ABVS) interpretation and agreement of ABVS findings with hand held breast ultrasound (HHUS), mammography and pathology results 
773 1 8 |g volume:82  |g year:2013  |g number:8  |g pages:e332-e336  |g extent:5  |a Interobserver reliability of automated breast volume scanner (ABVS) interpretation and agreement of ABVS findings with hand held breast ultrasound (HHUS), mammography and pathology results 
856 4 0 |u https://doi.org/10.1016/j.ejrad.2013.03.005  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0720048X13001320  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20210217 
993 |a Article 
994 |a 2013 
998 |g 132580187  |a Heil, Jörg  |m 132580187:Heil, Jörg  |d 910000  |d 910400  |e 910000PH132580187  |e 910400PH132580187  |k 0/910000/  |k 1/910000/910400/  |p 9  |y j 
998 |g 131349287  |a Sohn, Christof  |m 131349287:Sohn, Christof  |d 910000  |d 910400  |e 910000PS131349287  |e 910400PS131349287  |k 0/910000/  |k 1/910000/910400/  |p 8 
998 |g 12303387X  |a Schütz, Florian  |m 12303387X:Schütz, Florian  |d 910000  |d 910400  |e 910000PS12303387X  |e 910400PS12303387X  |k 0/910000/  |k 1/910000/910400/  |p 7 
998 |g 131622188  |a Scharf, Alexander  |m 131622188:Scharf, Alexander  |d 50000  |e 50000PS131622188  |k 0/50000/  |p 6 
998 |g 139823492  |a Rauch, Geraldine  |m 139823492:Rauch, Geraldine  |d 910000  |d 999701  |e 910000PR139823492  |e 999701PR139823492  |k 0/910000/  |k 1/910000/999701/  |p 5 
998 |g 1032985402  |a Junkermann, Hans  |m 1032985402:Junkermann, Hans  |d 910000  |d 910400  |e 910000PJ1032985402  |e 910400PJ1032985402  |k 0/910000/  |k 1/910000/910400/  |p 4 
998 |g 1136396004  |a Harcos, Aba  |m 1136396004:Harcos, Aba  |d 910000  |d 910400  |e 910000PH1136396004  |e 910400PH1136396004  |k 0/910000/  |k 1/910000/910400/  |p 3 
998 |g 1025404556  |a Franz, Dorothea  |m 1025404556:Franz, Dorothea  |p 2 
998 |g 132350386  |a Golatta, Michael  |m 132350386:Golatta, Michael  |d 910000  |d 910400  |e 910000PG132350386  |e 910400PG132350386  |k 0/910000/  |k 1/910000/910400/  |p 1  |x j 
999 |a KXP-PPN1748480022  |e 3856888594 
BIB |a Y 
SER |a journal 
JSO |a {"note":["Gesehen am 17.02.2020"],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"title":[{"title_sort":"Interobserver reliability of automated breast volume scanner (ABVS) interpretation and agreement of ABVS findings with hand held breast ultrasound (HHUS), mammography and pathology results","title":"Interobserver reliability of automated breast volume scanner (ABVS) interpretation and agreement of ABVS findings with hand held breast ultrasound (HHUS), mammography and pathology results"}],"person":[{"display":"Golatta, Michael","given":"Michael","role":"aut","family":"Golatta"},{"family":"Franz","role":"aut","given":"Dorothea","display":"Franz, Dorothea"},{"family":"Harcos","given":"Aba","role":"aut","display":"Harcos, Aba"},{"display":"Junkermann, Hans","role":"aut","given":"Hans","family":"Junkermann"},{"display":"Rauch, Geraldine","given":"Geraldine","role":"aut","family":"Rauch"},{"display":"Scharf, Alexander","family":"Scharf","given":"Alexander","role":"aut"},{"family":"Schütz","given":"Florian","role":"aut","display":"Schütz, Florian"},{"display":"Sohn, Christof","family":"Sohn","given":"Christof","role":"aut"},{"display":"Heil, Jörg","family":"Heil","given":"Jörg","role":"aut"}],"relHost":[{"type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng"],"note":["Gesehen am 05.02.20"],"title":[{"subtitle":"EJR","title":"European journal of radiology","title_sort":"European journal of radiology"}],"origin":[{"dateIssuedKey":"1990","publisherPlace":"Amsterdam [u.a.]","dateIssuedDisp":"1990-","publisher":"Elsevier Science"}],"disp":"Interobserver reliability of automated breast volume scanner (ABVS) interpretation and agreement of ABVS findings with hand held breast ultrasound (HHUS), mammography and pathology resultsEuropean journal of radiology","physDesc":[{"extent":"Online-Ressource"}],"recId":"32044483X","id":{"zdb":["2005350-2"],"eki":["32044483X"],"issn":["1872-7727"]},"part":{"pages":"e332-e336","issue":"8","extent":"5","text":"82(2013), 8, Seite e332-e336","year":"2013","volume":"82"},"titleAlt":[{"title":"EJR"}],"pubHistory":["Nachgewiesen 10.1990 -"]}],"origin":[{"dateIssuedKey":"2013","dateIssuedDisp":"27 March 2013"}],"physDesc":[{"extent":"5 S."}],"recId":"1748480022","id":{"eki":["1748480022"],"doi":["10.1016/j.ejrad.2013.03.005"]},"name":{"displayForm":["Michael Golatta, Dorothea Franz, Aba Harcos, Hans Junkermann, Geraldine Rauch, Alexander Scharf, Florian Schuetz, Christof Sohn, Joerg Heil"]}} 
SRT |a GOLATTAMICINTEROBSER2720