Towards quantitative image reconstruction using Monte-Carlo simulations in multi-wire proportional chamber-based small animal PET
The quadHIDAC is a dedicated high resolution small animal PET scanner based on multi-wire proportional chamber detectors. It provides very high spatial resolution, good sensitivity, and a large field-of-view allowing the examination of more than one animal in a single scan or a whole body scan of la...
Saved in:
| Main Authors: | , , , , , , |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
09 September 2013
|
| In: |
IEEE transactions on nuclear science
Year: 2013, Volume: 60, Issue: 5, Pages: 3343-3354 |
| ISSN: | 1558-1578 |
| DOI: | https://doi.org/10.1109/TNS.2013.2274703 |
| Online Access: | Verlag, lizenzpflichtig, Volltext: https://doi.org/https://doi.org/10.1109/TNS.2013.2274703 |
| Author Notes: | Holger Gottschlag, Thomas Kösters, Don Vernekohl, Klaus Reygers, Klaus P. Schäfers, Frank Wübbeling, and Johannes P. Wessels |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 174926269X | ||
| 003 | DE-627 | ||
| 005 | 20220819120223.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 210224s2013 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1109/TNS.2013.2274703 |2 doi | |
| 035 | |a (DE-627)174926269X | ||
| 035 | |a (DE-599)KXP174926269X | ||
| 035 | |a (OCoLC)1341395997 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 29 |2 sdnb | ||
| 100 | 1 | |a Gottschlag, Holger |d 1979- |e VerfasserIn |0 (DE-588)142423157 |0 (DE-627)635873656 |0 (DE-576)330619330 |4 aut | |
| 245 | 1 | 0 | |a Towards quantitative image reconstruction using Monte-Carlo simulations in multi-wire proportional chamber-based small animal PET |c Holger Gottschlag, Thomas Kösters, Don Vernekohl, Klaus Reygers, Klaus P. Schäfers, Frank Wübbeling, and Johannes P. Wessels |
| 264 | 1 | |c 09 September 2013 | |
| 300 | |a 12 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 24.02.2020 | ||
| 520 | |a The quadHIDAC is a dedicated high resolution small animal PET scanner based on multi-wire proportional chamber detectors. It provides very high spatial resolution, good sensitivity, and a large field-of-view allowing the examination of more than one animal in a single scan or a whole body scan of larger species in a single bed position. Excellent image quality has been obtained through list-mode-based EM reconstruction using resolution recovery. However, quantitative results on local uptake are still missing due to both (1) lack of energy discrimination and (2) inaccurate characterization of random events recorded by the scanner. In this work we describe how quantification can be achieved through the use of an appropriate Monte Carlo simulation of the quadHIDAC. The complex structure of the quadHIDAC has been completely implemented in a Geant4 simulation. Point sources, line sources, cylindrical phantoms, and voxelized image data have been successfully simulated and compared to real measurements. The magnitude and spatial distribution of scattered and random events could be quantitatively characterized for the different phantom geometries. The simulation provides access to information on single hit distributions resulting in appropriate randoms corrections in image reconstruction. Both randoms and scatter correction is demonstrated to improve quantification. Their accuracy and performance was tested on simulated and measured data. Using simulation-based correction techniques for quantitative image reconstruction, multi-wire proportional chamber-based PET technology may be attractive for future high resolution PET scanners. | ||
| 650 | 4 | |a Chamber | |
| 650 | 4 | |a Computational modeling | |
| 650 | 4 | |a cylindrical phantoms | |
| 650 | 4 | |a Detectors | |
| 650 | 4 | |a Geant4 | |
| 650 | 4 | |a Geant4 simulation | |
| 650 | 4 | |a HIDAC | |
| 650 | 4 | |a image quality | |
| 650 | 4 | |a image reconstruction | |
| 650 | 4 | |a Image reconstruction | |
| 650 | 4 | |a image resolution | |
| 650 | 4 | |a line sources | |
| 650 | 4 | |a list mode based EM reconstruction | |
| 650 | 4 | |a medical image processing | |
| 650 | 4 | |a Monte Carlo methods | |
| 650 | 4 | |a Monte Carlo simulation | |
| 650 | 4 | |a multi-wire | |
| 650 | 4 | |a multiwire proportional chamber detectors | |
| 650 | 4 | |a multiwire proportional chambers | |
| 650 | 4 | |a MWPC | |
| 650 | 4 | |a PET | |
| 650 | 4 | |a Photonics | |
| 650 | 4 | |a point sources | |
| 650 | 4 | |a positron emission tomography | |
| 650 | 4 | |a Positron emission tomography | |
| 650 | 4 | |a Positrons | |
| 650 | 4 | |a proportional | |
| 650 | 4 | |a quadHIDAC | |
| 650 | 4 | |a quantitative | |
| 650 | 4 | |a quantitative image reconstruction | |
| 650 | 4 | |a randoms | |
| 650 | 4 | |a resolution recovery | |
| 650 | 4 | |a scatter | |
| 650 | 4 | |a sensitivity | |
| 650 | 4 | |a simulation | |
| 650 | 4 | |a small animal PET | |
| 650 | 4 | |a spatial resolution | |
| 650 | 4 | |a trues | |
| 650 | 4 | |a voxelized image data | |
| 700 | 1 | |a Kösters, Thomas |d 1981- |e VerfasserIn |0 (DE-588)142052116 |0 (DE-627)63351554X |0 (DE-576)326971017 |4 aut | |
| 700 | 1 | |a Vernekohl, Don |d 1983- |e VerfasserIn |0 (DE-588)1054051372 |0 (DE-627)791013049 |0 (DE-576)40997420X |4 aut | |
| 700 | 1 | |a Reygers, Klaus |d 1969- |e VerfasserIn |0 (DE-588)121899594 |0 (DE-627)705695018 |0 (DE-576)292945892 |4 aut | |
| 700 | 1 | |a Schäfers, Klaus Peter |d 1968- |e VerfasserIn |0 (DE-588)122694848 |0 (DE-627)706003861 |0 (DE-576)293384975 |4 aut | |
| 700 | 1 | |a Wübbeling, Frank |e VerfasserIn |4 aut | |
| 700 | 1 | |a Wessels, Johannes P. |d 1962- |e VerfasserIn |0 (DE-588)1153501856 |0 (DE-627)1014924634 |0 (DE-576)167340735 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |a Institute of Electrical and Electronics Engineers |t IEEE transactions on nuclear science |d New York, NY : IEEE, 1963 |g 60(2013), 5, Seite 3343-3354 |h Online-Ressource |w (DE-627)320645835 |w (DE-600)2025398-9 |w (DE-576)094110956 |x 1558-1578 |7 nnas |
| 773 | 1 | 8 | |g volume:60 |g year:2013 |g number:5 |g pages:3343-3354 |g extent:12 |a Towards quantitative image reconstruction using Monte-Carlo simulations in multi-wire proportional chamber-based small animal PET |
| 856 | 4 | 0 | |u https://doi.org/https://doi.org/10.1109/TNS.2013.2274703 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20210224 | ||
| 993 | |a Article | ||
| 994 | |a 2013 | ||
| 998 | |g 1153501856 |a Wessels, Johannes P. |m 1153501856:Wessels, Johannes P. |p 7 |y j | ||
| 998 | |g 121899594 |a Reygers, Klaus |m 121899594:Reygers, Klaus |d 130000 |d 130200 |e 130000PR121899594 |e 130200PR121899594 |k 0/130000/ |k 1/130000/130200/ |p 1 |x j | ||
| 999 | |a KXP-PPN174926269X |e 3872360396 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"title":[{"title_sort":"Towards quantitative image reconstruction using Monte-Carlo simulations in multi-wire proportional chamber-based small animal PET","title":"Towards quantitative image reconstruction using Monte-Carlo simulations in multi-wire proportional chamber-based small animal PET"}],"language":["eng"],"name":{"displayForm":["Holger Gottschlag, Thomas Kösters, Don Vernekohl, Klaus Reygers, Klaus P. Schäfers, Frank Wübbeling, and Johannes P. Wessels"]},"origin":[{"dateIssuedKey":"2013","dateIssuedDisp":"09 September 2013"}],"recId":"174926269X","person":[{"family":"Gottschlag","given":"Holger","display":"Gottschlag, Holger","role":"aut"},{"role":"aut","given":"Thomas","display":"Kösters, Thomas","family":"Kösters"},{"family":"Vernekohl","display":"Vernekohl, Don","given":"Don","role":"aut"},{"family":"Reygers","given":"Klaus","display":"Reygers, Klaus","role":"aut"},{"role":"aut","family":"Schäfers","given":"Klaus Peter","display":"Schäfers, Klaus Peter"},{"given":"Frank","display":"Wübbeling, Frank","family":"Wübbeling","role":"aut"},{"display":"Wessels, Johannes P.","given":"Johannes P.","family":"Wessels","role":"aut"}],"note":["Gesehen am 24.02.2020"],"relHost":[{"note":["Gesehen am 12.12.07"],"part":{"pages":"3343-3354","year":"2013","text":"60(2013), 5, Seite 3343-3354","volume":"60","issue":"5","extent":"12"},"id":{"eki":["320645835"],"issn":["1558-1578"],"zdb":["2025398-9"]},"physDesc":[{"extent":"Online-Ressource"}],"title":[{"subtitle":"a publication of the IEEE Nuclear and Plasma Sciences Society","title_sort":"IEEE transactions on nuclear science","title":"IEEE transactions on nuclear science"}],"corporate":[{"role":"aut","display":"Institute of Electrical and Electronics Engineers"}],"origin":[{"dateIssuedDisp":"1963-","publisher":"IEEE","publisherPlace":"New York, NY","dateIssuedKey":"1963"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"pubHistory":["10.1963 -"],"titleAlt":[{"title":"Transactions on nuclear science"}],"language":["eng"],"recId":"320645835","disp":"Institute of Electrical and Electronics EngineersIEEE transactions on nuclear science"}],"id":{"eki":["174926269X"],"doi":["10.1109/TNS.2013.2274703"]},"type":{"media":"Online-Ressource","bibl":"article-journal"},"physDesc":[{"extent":"12 S."}]} | ||
| SRT | |a GOTTSCHLAGTOWARDSQUA0920 | ||