Dual response audiometry: a time-saving technique for enhanced objective auditory assessment

The effectiveness of objective audiometric assessment can be improved by simultaneously recording transient evoked otoacoustic emissions (TEOAE) and auditory brainstem responses (ABR). Using a stimulation paradigm based on sequences of linearly balanced click stimuli (as described by Kemp et al.1) a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Hoth, Sebastian (VerfasserIn) , Lochmann, Holger Peer (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 1999
In: International journal of audiology
Year: 1999, Jahrgang: 38, Heft: 4, Pages: 235-240
ISSN:1708-8186
DOI:10.3109/00206099909073027
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.3109/00206099909073027
Verlag, lizenzpflichtig, Volltext: https://www.tandfonline.com/doi/abs/10.3109/00206099909073027
Volltext
Verfasserangaben:Sebastian Hoth & Holger Lochmann

MARC

LEADER 00000caa a2200000 c 4500
001 1749425106
003 DE-627
005 20220819121256.0
007 cr uuu---uuuuu
008 210225s1999 xx |||||o 00| ||eng c
024 7 |a 10.3109/00206099909073027  |2 doi 
035 |a (DE-627)1749425106 
035 |a (DE-599)KXP1749425106 
035 |a (OCoLC)1341396131 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Hoth, Sebastian  |d 1954-  |e VerfasserIn  |0 (DE-588)115541837  |0 (DE-627)077317998  |0 (DE-576)161494110  |4 aut 
245 1 0 |a Dual response audiometry  |b a time-saving technique for enhanced objective auditory assessment  |c Sebastian Hoth & Holger Lochmann 
264 1 |c 1999 
300 |a 6 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Elektronische Reproduktion der Druck-Ausgabe 
500 |a Gesehen am 25.02.2021 
520 |a The effectiveness of objective audiometric assessment can be improved by simultaneously recording transient evoked otoacoustic emissions (TEOAE) and auditory brainstem responses (ABR). Using a stimulation paradigm based on sequences of linearly balanced click stimuli (as described by Kemp et al.1) acoustical and electrical responses of the auditory system can be obtained in one single run (dual response audiometry, DRA). The click stimuli are presented via an ear canal probe containing a speaker and a miniature microphone. EEG activity is recorded from surface electrodes fixed at the vertex and the mastoid ipsilateral to stimulus presentation. Microphone output and voltage difference between electrodes are fed into a dual-channel data acquisition system, where they are separately amplified and filtered into appropriate frequency ranges. After each stimulus, sweeps of 256 samples within a time window of 17 ms are taken of both signals. They are subject to artefact rejection and averaging of amplitude and polarity. The electrical responses to low and high level clicks within one stimulus sequence are processed separately, whereas the acoustical responses are summated across levels in order to eliminate stimulus-related contamination. As the result of one single run, ABR at two levels and non-linear TEOAEs are obtained within approximately 1 min. The signal quality is estimated by correlation analysis and binomial statistics. Among various features of DRA, the most important advantage is the improvement of the success rate. The influence of perturbations is limited since muscle artefacts due to motor activity affect only the ABR, whereas noise contamination affects only the TEOAE. The accuracy of threshold determination is better than with conventional ABR since the stimulus level is measured in situ. One DRA examination provides complete information about the functional integrity of the cochlea and neural pathways without additional time. It appears ideal for the application as a second stage infant screen. 
650 4 |a Auditory brainstem responses 
650 4 |a Hearing disorders 
650 4 |a Infant screening 
650 4 |a Objective audiometry 
650 4 |a Otoacoustic emissions 
700 1 |a Lochmann, Holger Peer  |d 1973-  |e VerfasserIn  |0 (DE-588)124379699  |0 (DE-627)363306978  |0 (DE-576)294145826  |4 aut 
773 0 8 |i Enthalten in  |t International journal of audiology  |d London [u.a.] : Taylor & Francis Group, 2002  |g 38(1999), 4, Seite 235-240  |h Online-Ressource  |w (DE-627)344918408  |w (DE-600)2074671-4  |w (DE-576)254167586  |x 1708-8186  |7 nnas  |a Dual response audiometry a time-saving technique for enhanced objective auditory assessment 
773 1 8 |g volume:38  |g year:1999  |g number:4  |g pages:235-240  |g extent:6  |a Dual response audiometry a time-saving technique for enhanced objective auditory assessment 
856 4 0 |u https://doi.org/10.3109/00206099909073027  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.tandfonline.com/doi/abs/10.3109/00206099909073027  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20210225 
993 |a Article 
994 |a 1999 
998 |g 124379699  |a Lochmann, Holger Peer  |m 124379699:Lochmann, Holger Peer  |d 50000  |e 50000PL124379699  |k 0/50000/  |p 2  |y j 
998 |g 115541837  |a Hoth, Sebastian  |m 115541837:Hoth, Sebastian  |d 910000  |d 911000  |e 910000PH115541837  |e 911000PH115541837  |k 0/910000/  |k 1/910000/911000/  |p 1  |x j 
999 |a KXP-PPN1749425106  |e 3874341348 
BIB |a Y 
SER |a journal 
JSO |a {"person":[{"role":"aut","given":"Sebastian","display":"Hoth, Sebastian","family":"Hoth"},{"role":"aut","given":"Holger Peer","family":"Lochmann","display":"Lochmann, Holger Peer"}],"title":[{"subtitle":"a time-saving technique for enhanced objective auditory assessment","title_sort":"Dual response audiometry","title":"Dual response audiometry"}],"note":["Elektronische Reproduktion der Druck-Ausgabe","Gesehen am 25.02.2021"],"origin":[{"dateIssuedDisp":"1999","dateIssuedKey":"1999"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"physDesc":[{"extent":"6 S."}],"name":{"displayForm":["Sebastian Hoth & Holger Lochmann"]},"recId":"1749425106","id":{"doi":["10.3109/00206099909073027"],"eki":["1749425106"]},"relHost":[{"pubHistory":["41.2002 -"],"recId":"344918408","physDesc":[{"extent":"Online-Ressource"}],"id":{"zdb":["2074671-4"],"issn":["1708-8186"],"eki":["344918408"]},"disp":"Dual response audiometry a time-saving technique for enhanced objective auditory assessmentInternational journal of audiology","language":["eng"],"type":{"media":"Online-Ressource","bibl":"periodical"},"note":["Fortsetzung der Druck-Ausgabe","Gesehen am 20.11.18"],"origin":[{"publisherPlace":"London [u.a.] ; London [u.a.] ; Hamilton","dateIssuedDisp":"2002-","publisher":"Taylor & Francis Group ; Informa Healthcare ; Decker","dateIssuedKey":"2002"}],"title":[{"title":"International journal of audiology","title_sort":"International journal of audiology"}],"part":{"issue":"4","year":"1999","pages":"235-240","text":"38(1999), 4, Seite 235-240","extent":"6","volume":"38"}}]} 
SRT |a HOTHSEBASTDUALRESPON1999