Effectiveness of a new perforated 0.15 mm poly-p-dioxanon-foil versus titanium-dynamic mesh in reconstruction of the orbital floor

Introduction: In recent years a new perforated PDS (poly-p-dioxanon) foil (0.15 mm) has become available and has not yet been proven to be successful in reconstruction of the orbital floor after blow-out-fractures in randomized studies. The main aim of this clinical trial is to compare this new PDS...

Full description

Saved in:
Bibliographic Details
Main Authors: Dietz, Andreas (Author) , Ziegler, Christoph (Author) , Dacho, Andreas (Author) , Althof, Frank (Author) , Conradt, Christian (Author) , Kolling, Gerold (Author) , Boehmer, Hubertus von (Author) , Steffen, Heimo (Author)
Format: Article (Journal)
Language:English
Published: [2001]
In: Journal of cranio-maxillofacial surgery
Year: 2001, Volume: 29, Issue: 2, Pages: 82-88
ISSN:1878-4119
DOI:10.1054/jcms.2000.0188
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1054/jcms.2000.0188
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S1010518200901884
Get full text
Author Notes:Andreas Dietz, Christoph M. Ziegler, Andreas Dacho, Frank Althof, Christian Conradt, Gerold Kolling, Hubertus von Boehmer, Heimo Steffen

MARC

LEADER 00000caa a2200000 c 4500
001 1750123274
003 DE-627
005 20220819123415.0
007 cr uuu---uuuuu
008 210302s2001 xx |||||o 00| ||eng c
024 7 |a 10.1054/jcms.2000.0188  |2 doi 
035 |a (DE-627)1750123274 
035 |a (DE-599)KXP1750123274 
035 |a (OCoLC)1341396481 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Dietz, Andreas  |d 1962-  |e VerfasserIn  |0 (DE-588)136799272  |0 (DE-627)694667137  |0 (DE-576)301281491  |4 aut 
245 1 0 |a Effectiveness of a new perforated 0.15 mm poly-p-dioxanon-foil versus titanium-dynamic mesh in reconstruction of the orbital floor  |c Andreas Dietz, Christoph M. Ziegler, Andreas Dacho, Frank Althof, Christian Conradt, Gerold Kolling, Hubertus von Boehmer, Heimo Steffen 
264 1 |c [2001] 
300 |b Illustrationen 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 02.03.2021 
520 |a Introduction: In recent years a new perforated PDS (poly-p-dioxanon) foil (0.15 mm) has become available and has not yet been proven to be successful in reconstruction of the orbital floor after blow-out-fractures in randomized studies. The main aim of this clinical trial is to compare this new PDS foil with titanium dynamic mesh (0.3 mm) (TD), which is well established in reconstruction of the orbital floor. Patients and Methods: In a prospective multicentre randomized trial, conducted between 1997 and 1998, out of 42 patients with fractures of the orbital floor, 28 patients needing material for reconstruction were randomized to receive either PDS foil or TD. In a comprehensive preoperative and postoperative protocol patients were monitored by the surgeon, radiologist and ophthalmologist with a postoperative follow-up of least 6 months. Results: Maximum defects of the orbital floor were comparable in both groups (PDS group: 13.3 mm, TD group: 13.9 mm). In both groups the surgical procedure was well tolerated, and functional and cosmetic results were evaluated as satisfactory by all patients. Ophthalmological evaluation, performed up to 6 months postoperatively, revealed double vision or vertical strabismus in nine patients (five PDS group, four titanium group). This was not confirmed subjectively in each single patient. Also ex- or enophthalmos, registered in seven patients of the PDS and four of the TD group (mainly +/−1 mm) were not considered as relevant by the patients. Conclusion: The new 0.15 mm perforated PDS foil was comparable to 0.3 mm titanium mesh concerning functional and cosmetic outcome. Obviously, persisting ophthalmometric disorders were compensated very well in both groups. PDS foil is felt to be the preferred material since it is bioresorbable and more convenient to handle. 
700 1 |a Ziegler, Christoph  |e VerfasserIn  |0 (DE-588)1074854438  |0 (DE-627)832594849  |0 (DE-576)443014701  |4 aut 
700 1 |a Dacho, Andreas  |d 1970-  |e VerfasserIn  |0 (DE-588)122747356  |0 (DE-627)706026551  |0 (DE-576)293404348  |4 aut 
700 1 |a Althof, Frank  |d 1964-  |e VerfasserIn  |0 (DE-588)115574883  |0 (DE-627)691421331  |0 (DE-576)289957656  |4 aut 
700 1 |a Conradt, Christian  |e VerfasserIn  |0 (DE-588)1228367701  |0 (DE-627)1750129418  |4 aut 
700 1 |a Kolling, Gerold  |e VerfasserIn  |0 (DE-588)1022809369  |0 (DE-627)717044734  |0 (DE-576)366014420  |4 aut 
700 1 |a Boehmer, Hubertus von  |d 1963-  |e VerfasserIn  |0 (DE-588)1228354308  |0 (DE-627)1750117606  |4 aut 
700 1 |a Steffen, Heimo  |d 1960-  |e VerfasserIn  |0 (DE-588)1077339283  |0 (DE-627)83634183X  |0 (DE-576)169294927  |4 aut 
773 0 8 |i Enthalten in  |t Journal of cranio-maxillofacial surgery  |d Oxford [u.a.] : Elsevier, 1987  |g 29(2001), 2, Seite 82-88  |h Online-Ressource  |w (DE-627)320479218  |w (DE-600)2009565-X  |w (DE-576)10374696X  |x 1878-4119  |7 nnas  |a Effectiveness of a new perforated 0.15 mm poly-p-dioxanon-foil versus titanium-dynamic mesh in reconstruction of the orbital floor 
773 1 8 |g volume:29  |g year:2001  |g number:2  |g pages:82-88  |g extent:7  |a Effectiveness of a new perforated 0.15 mm poly-p-dioxanon-foil versus titanium-dynamic mesh in reconstruction of the orbital floor 
856 4 0 |u https://doi.org/10.1054/jcms.2000.0188  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S1010518200901884  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20210302 
993 |a Article 
994 |a 2001 
998 |g 1077339283  |a Steffen, Heimo  |m 1077339283:Steffen, Heimo  |d 910000  |d 910900  |e 910000PS1077339283  |e 910900PS1077339283  |k 0/910000/  |k 1/910000/910900/  |p 8  |y j 
998 |g 1228354308  |a Boehmer, Hubertus von  |m 1228354308:Boehmer, Hubertus von  |p 7 
998 |g 1022809369  |a Kolling, Gerold  |m 1022809369:Kolling, Gerold  |d 910000  |d 910900  |e 910000PK1022809369  |e 910900PK1022809369  |k 0/910000/  |k 1/910000/910900/  |p 6 
998 |g 1228367701  |a Conradt, Christian  |m 1228367701:Conradt, Christian  |d 910000  |d 999701  |e 910000PC1228367701  |e 999701PC1228367701  |k 0/910000/  |k 1/910000/999701/  |p 5 
998 |g 115574883  |a Althof, Frank  |m 115574883:Althof, Frank  |p 4 
998 |g 122747356  |a Dacho, Andreas  |m 122747356:Dacho, Andreas  |d 910000  |d 911000  |e 910000PD122747356  |e 911000PD122747356  |k 0/910000/  |k 1/910000/911000/  |p 3 
998 |g 1074854438  |a Ziegler, Christoph  |m 1074854438:Ziegler, Christoph  |d 910000  |d 910800  |e 910000PZ1074854438  |e 910800PZ1074854438  |k 0/910000/  |k 1/910000/910800/  |p 2 
998 |g 136799272  |a Dietz, Andreas  |m 136799272:Dietz, Andreas  |d 910000  |d 911000  |e 910000PD136799272  |e 911000PD136799272  |k 0/910000/  |k 1/910000/911000/  |p 1  |x j 
999 |a KXP-PPN1750123274  |e 3879936161 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"origin":[{"publisher":"Elsevier ; Churchill Livingstone","dateIssuedKey":"1987","dateIssuedDisp":"1987-","publisherPlace":"Oxford [u.a.] ; Edinburgh [u.a.]"}],"id":{"issn":["1878-4119"],"zdb":["2009565-X"],"eki":["320479218"]},"physDesc":[{"extent":"Online-Ressource"}],"title":[{"subtitle":"official publication of the European Association for Cranio-Maxillofacial Surgery","title":"Journal of cranio-maxillofacial surgery","title_sort":"Journal of cranio-maxillofacial surgery"}],"pubHistory":["Nachgewiesen 15.1987 -"],"part":{"pages":"82-88","issue":"2","year":"2001","extent":"7","volume":"29","text":"29(2001), 2, Seite 82-88"},"type":{"media":"Online-Ressource","bibl":"periodical"},"note":["Gesehen am 11.06.18"],"disp":"Effectiveness of a new perforated 0.15 mm poly-p-dioxanon-foil versus titanium-dynamic mesh in reconstruction of the orbital floorJournal of cranio-maxillofacial surgery","recId":"320479218","language":["eng"]}],"physDesc":[{"extent":"7 S.","noteIll":"Illustrationen"}],"name":{"displayForm":["Andreas Dietz, Christoph M. Ziegler, Andreas Dacho, Frank Althof, Christian Conradt, Gerold Kolling, Hubertus von Boehmer, Heimo Steffen"]},"id":{"eki":["1750123274"],"doi":["10.1054/jcms.2000.0188"]},"origin":[{"dateIssuedKey":"2001","dateIssuedDisp":"[2001]"}],"language":["eng"],"recId":"1750123274","note":["Gesehen am 02.03.2021"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"person":[{"family":"Dietz","given":"Andreas","display":"Dietz, Andreas","roleDisplay":"VerfasserIn","role":"aut"},{"display":"Ziegler, Christoph","roleDisplay":"VerfasserIn","role":"aut","family":"Ziegler","given":"Christoph"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Dacho, Andreas","given":"Andreas","family":"Dacho"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Althof, Frank","given":"Frank","family":"Althof"},{"display":"Conradt, Christian","roleDisplay":"VerfasserIn","role":"aut","family":"Conradt","given":"Christian"},{"family":"Kolling","given":"Gerold","roleDisplay":"VerfasserIn","display":"Kolling, Gerold","role":"aut"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Boehmer, Hubertus von","given":"Hubertus von","family":"Boehmer"},{"family":"Steffen","given":"Heimo","roleDisplay":"VerfasserIn","display":"Steffen, Heimo","role":"aut"}],"title":[{"title":"Effectiveness of a new perforated 0.15 mm poly-p-dioxanon-foil versus titanium-dynamic mesh in reconstruction of the orbital floor","title_sort":"Effectiveness of a new perforated 0.15 mm poly-p-dioxanon-foil versus titanium-dynamic mesh in reconstruction of the orbital floor"}]} 
SRT |a DIETZANDREEFFECTIVEN2001