Backside wear in total knee replacement: a new quantitative measurement method and a comparison of polished cobalt-chromium tibial trays with titanium tibial trays
Introduction - In modular total knee replacements, polyethylene backside wear can occur due to micro-motion between the tibial tray and polyethylene insert. Tibial trays manufactured from a cobalt-chromium alloy with highly polished surfaces are increasingly used to prevent backside wear. However, t...
Gespeichert in:
| Hauptverfasser: | , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
2021
|
| In: |
Wear
Year: 2020, Jahrgang: 466/467 |
| ISSN: | 1873-2577 |
| DOI: | 10.1016/j.wear.2020.203552 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.wear.2020.203552 Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0043164820310115 |
| Verfasserangaben: | Steffen Braun, Maximilian Uhler, Therese Bormann, Stefan Schroeder, Sebastian Jaeger, Robert Sonntag, Jan Philippe Kretzer |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1750138972 | ||
| 003 | DE-627 | ||
| 005 | 20240412193205.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 210302r20212020xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.wear.2020.203552 |2 doi | |
| 035 | |a (DE-627)1750138972 | ||
| 035 | |a (DE-599)KXP1750138972 | ||
| 035 | |a (OCoLC)1341396718 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Braun, Steffen |d 1988- |e VerfasserIn |0 (DE-588)1149869429 |0 (DE-627)1010183974 |0 (DE-576)496872729 |4 aut | |
| 245 | 1 | 0 | |a Backside wear in total knee replacement |b a new quantitative measurement method and a comparison of polished cobalt-chromium tibial trays with titanium tibial trays |c Steffen Braun, Maximilian Uhler, Therese Bormann, Stefan Schroeder, Sebastian Jaeger, Robert Sonntag, Jan Philippe Kretzer |
| 264 | 1 | |c 2021 | |
| 300 | |a 11 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Available online 1 December 2020 | ||
| 500 | |a Gesehen am 03.03.2021 | ||
| 520 | |a Introduction - In modular total knee replacements, polyethylene backside wear can occur due to micro-motion between the tibial tray and polyethylene insert. Tibial trays manufactured from a cobalt-chromium alloy with highly polished surfaces are increasingly used to prevent backside wear. However, there is no quantitative evidence for this supposed wear advantage because previous evaluations only considered the subjective assessment of surface damage and changes without any information about the characteristics of the generated wear products. The validity about a true wear in the form of material removal is often missing. Therefore, this study used a new method to quantitatively investigate the possible wear advantage of polished cobalt-chromium tibial trays. - Materials and methods - Total knee replacements with titanium and polished cobalt-chromium tibial trays (SIGMA® DePuy Synthes & Johnson&Johnson, USA) were tested in a physiological knee wear simulator according to ISO-14243-1 for 3 x 106 cycles. The articulation side was hermetically separated from the backside of the insert. The serum was analyzed separately by particle analysis according to ASTM-F1877. - Results - With polished cobalt-chromium tibial trays, significantly (p = 0.003) less backside wear particles was generated. The backside wear particles differ significantly in size and morphology from the articulating particles. - Conclusion - In this study, backside wear was measured quantitatively and its wear particles were characterized for the first time. We demonstrated that even with modern inlay locking mechanisms and polished surfaces, wear particles on the backside can account for 15-33% of total wear. With polished cobalt-chromium trays, significantly less backside wear particles was generated. | ||
| 534 | |c 2020 | ||
| 650 | 4 | |a Backside wear | |
| 650 | 4 | |a Cobalt-chromium-alloy | |
| 650 | 4 | |a Particle analysis | |
| 650 | 4 | |a Polished tibial tray | |
| 650 | 4 | |a Total knee replacement | |
| 700 | 1 | |a Uhler, Maximilian |e VerfasserIn |0 (DE-588)1211349799 |0 (DE-627)1699088438 |4 aut | |
| 700 | 1 | |a Bormann, Therese |e VerfasserIn |0 (DE-588)1205894829 |0 (DE-627)1691740136 |4 aut | |
| 700 | 1 | |a Schröder, Stefan |d 1989- |e VerfasserIn |0 (DE-588)1191520447 |0 (DE-627)1670141438 |4 aut | |
| 700 | 1 | |a Jäger, Sebastian |d 1975- |e VerfasserIn |0 (DE-588)1059313731 |0 (DE-627)79828238X |0 (DE-576)415306647 |4 aut | |
| 700 | 1 | |a Sonntag, Robert |e VerfasserIn |0 (DE-588)1068843756 |0 (DE-627)82081699X |0 (DE-576)428211135 |4 aut | |
| 700 | 1 | |a Kretzer, Jan Philippe |d 1978- |e VerfasserIn |0 (DE-588)136998348 |0 (DE-627)589003690 |0 (DE-576)301383103 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Wear |d Amsterdam [u.a.] : Elsevier Science, 1957 |g 466/467(2021), Artikel-ID 203552 |h Online-Ressource |w (DE-627)306714027 |w (DE-600)1501123-9 |w (DE-576)098474030 |x 1873-2577 |7 nnas |a Backside wear in total knee replacement a new quantitative measurement method and a comparison of polished cobalt-chromium tibial trays with titanium tibial trays |
| 773 | 1 | 8 | |g volume:466/467 |g year:2021 |g elocationid:203552 |g extent:11 |a Backside wear in total knee replacement a new quantitative measurement method and a comparison of polished cobalt-chromium tibial trays with titanium tibial trays |
| 856 | 4 | 0 | |u https://doi.org/10.1016/j.wear.2020.203552 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://www.sciencedirect.com/science/article/pii/S0043164820310115 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20210302 | ||
| 993 | |a Article | ||
| 994 | |a 2021 | ||
| 998 | |g 136998348 |a Kretzer, Jan Philippe |m 136998348:Kretzer, Jan Philippe |d 910000 |d 911460 |d 50000 |e 910000PK136998348 |e 911460PK136998348 |e 50000PK136998348 |k 0/910000/ |k 1/910000/911460/ |k 0/50000/ |p 7 |y j | ||
| 998 | |g 1068843756 |a Sonntag, Robert |m 1068843756:Sonntag, Robert |d 910000 |d 911460 |e 910000PS1068843756 |e 911460PS1068843756 |k 0/910000/ |k 1/910000/911460/ |p 6 | ||
| 998 | |g 1059313731 |a Jäger, Sebastian |m 1059313731:Jäger, Sebastian |d 910000 |d 911460 |e 910000PJ1059313731 |e 911460PJ1059313731 |k 0/910000/ |k 1/910000/911460/ |p 5 | ||
| 998 | |g 1191520447 |a Schröder, Stefan |m 1191520447:Schröder, Stefan |d 910000 |d 911460 |e 910000PS1191520447 |e 911460PS1191520447 |k 0/910000/ |k 1/910000/911460/ |p 4 | ||
| 998 | |g 1205894829 |a Bormann, Therese |m 1205894829:Bormann, Therese |d 910000 |d 911460 |e 910000PB1205894829 |e 911460PB1205894829 |k 0/910000/ |k 1/910000/911460/ |p 3 | ||
| 998 | |g 1211349799 |a Uhler, Maximilian |m 1211349799:Uhler, Maximilian |d 910000 |d 911460 |e 910000PU1211349799 |e 911460PU1211349799 |k 0/910000/ |k 1/910000/911460/ |p 2 | ||
| 998 | |g 1149869429 |a Braun, Steffen |m 1149869429:Braun, Steffen |d 50000 |e 50000PB1149869429 |k 0/50000/ |p 1 |x j | ||
| 999 | |a KXP-PPN1750138972 |e 3880118965 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"language":["eng"],"name":{"displayForm":["Steffen Braun, Maximilian Uhler, Therese Bormann, Stefan Schroeder, Sebastian Jaeger, Robert Sonntag, Jan Philippe Kretzer"]},"type":{"bibl":"article-journal","media":"Online-Ressource"},"physDesc":[{"extent":"11 S."}],"id":{"doi":["10.1016/j.wear.2020.203552"],"eki":["1750138972"]},"title":[{"subtitle":"a new quantitative measurement method and a comparison of polished cobalt-chromium tibial trays with titanium tibial trays","title":"Backside wear in total knee replacement","title_sort":"Backside wear in total knee replacement"}],"person":[{"family":"Braun","role":"aut","given":"Steffen","display":"Braun, Steffen"},{"given":"Maximilian","display":"Uhler, Maximilian","role":"aut","family":"Uhler"},{"given":"Therese","display":"Bormann, Therese","role":"aut","family":"Bormann"},{"role":"aut","given":"Stefan","display":"Schröder, Stefan","family":"Schröder"},{"role":"aut","given":"Sebastian","display":"Jäger, Sebastian","family":"Jäger"},{"family":"Sonntag","display":"Sonntag, Robert","given":"Robert","role":"aut"},{"family":"Kretzer","given":"Jan Philippe","display":"Kretzer, Jan Philippe","role":"aut"}],"origin":[{"dateIssuedDisp":"2021","dateIssuedKey":"2021"}],"note":["Available online 1 December 2020","Gesehen am 03.03.2021"],"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"disp":"Backside wear in total knee replacement a new quantitative measurement method and a comparison of polished cobalt-chromium tibial trays with titanium tibial traysWear","part":{"year":"2021","text":"466/467(2021), Artikel-ID 203552","extent":"11","volume":"466/467"},"title":[{"title_sort":"Wear","subtitle":"an international journal on the science and technology of friction, lubrication and wear","title":"Wear"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"recId":"306714027","pubHistory":["1.1957 - 319.2014; Vol. 320.2014 -"],"origin":[{"publisherPlace":"Amsterdam [u.a.]","dateIssuedDisp":"1957-","publisher":"Elsevier Science","dateIssuedKey":"1957"}],"note":["Gesehen am 21.11.23"],"id":{"issn":["1873-2577"],"eki":["306714027"],"zdb":["1501123-9"]},"language":["eng"]}],"recId":"1750138972"} | ||
| SRT | |a BRAUNSTEFFBACKSIDEWE2021 | ||