Accuracy of right and left ventricular functional assessment by short-axis vs axial cine steady-state free-precession magnetic resonance imaging: intrapatient correlation with main pulmonary artery and ascending aorta phase-contrast flow measurements

ObjectiveThe left ventricle (LV) is routinely assessed with cardiac magnetic resonance imaging (MRI) by using short-axis orientation; it remains unclear whether the right ventricle (RV) can also be adequately assessed in this orientation or whether dedicated axial orientation is required. We used ph...

Full description

Saved in:
Bibliographic Details
Main Authors: James, Susan H. (Author) , Wald, Rachel (Author) , Wintersperger, Bernd (Author) , Jimenez-Juan, Laura (Author) , Deva, Djeven (Author) , Crean, Andrew M. (Author) , Nguyen, Elsie (Author) , Paul, Narinder S. (Author) , Ley, Sebastian (Author)
Format: Article (Journal)
Language:English
Published: August 1, 2013
In: Canadian Association of Radiologists journal
Year: 2013, Volume: 64, Issue: 3, Pages: 213-219
ISSN:1488-2361
DOI:10.1016/j.carj.2011.12.016
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.carj.2011.12.016
Get full text
Author Notes:Susan H. James, MD, Rachel Wald, MD, Bernd J. Wintersperger, MD, Laura Jimenez-Juan, MD, Djeven Deva, MD, Andrew M. Crean, MD, Elsie Nguyen, MD, Narinder S. Paul, MD, Sebastian Ley, MD

MARC

LEADER 00000caa a2200000 c 4500
001 1752417828
003 DE-627
005 20230427070815.0
007 cr uuu---uuuuu
008 210325s2013 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.carj.2011.12.016  |2 doi 
035 |a (DE-627)1752417828 
035 |a (DE-599)KXP1752417828 
035 |a (OCoLC)1341401358 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a James, Susan H.  |e VerfasserIn  |0 (DE-588)1230073949  |0 (DE-627)1752416058  |4 aut 
245 1 0 |a Accuracy of right and left ventricular functional assessment by short-axis vs axial cine steady-state free-precession magnetic resonance imaging  |b intrapatient correlation with main pulmonary artery and ascending aorta phase-contrast flow measurements  |c Susan H. James, MD, Rachel Wald, MD, Bernd J. Wintersperger, MD, Laura Jimenez-Juan, MD, Djeven Deva, MD, Andrew M. Crean, MD, Elsie Nguyen, MD, Narinder S. Paul, MD, Sebastian Ley, MD 
246 3 0 |a versus 
264 1 |c August 1, 2013 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 25.03.2021 
520 |a ObjectiveThe left ventricle (LV) is routinely assessed with cardiac magnetic resonance imaging (MRI) by using short-axis orientation; it remains unclear whether the right ventricle (RV) can also be adequately assessed in this orientation or whether dedicated axial orientation is required. We used phase-contrast (PC) flow measurements in the main pulmonary artery (MPA) and the ascending aorta (Aorta) as nonvolumetric standard of reference and compared RV and LV volumes in short-axis and axial orientations.MethodsA retrospective analysis identified 30 patients with cardiac MRI data sets. Patients underwent MRI (1.5 T or 3 T), with retrospectively gated cine steady-state free-precession in axial and short-axis orientations. PC flow analyses of MPA and Aorta were used as the reference measure of RV and LV output.ResultsThere was a high linear correlation between MPA-PC flow and RV?stroke volume (SV) short axis (r = 0.9) and RV-SV axial (r = 0.9). Bland-Altman analysis revealed a mean offset of 1.4 mL for RV axial and ?2.3 mL for RV?short-axis vs MPA-PC flow. There was a high linear correlation between Aorta-PC flow and LV-SV short-axis (r = 0.9) and LV-SV axial (r = 0.9). Bland-Altman analysis revealed a mean offset of 4.8 m for LV short axis and 7.0 mL for LV axial vs Aorta-PC flow. There was no significant difference (P = .6) between short-axis?LV SV and short-axis?RV SV.ConclusionNo significant impact of the slice acquisition orientation for determination of RV and LV stroke volumes was found. Therefore, cardiac magnetic resonance workflow does not need to be extended by an axial data set for patients without complex cardiac disease for assessment of biventricular function and volumes. 
650 4 |a Cine 
650 4 |a Magnetic resonance imaging 
650 4 |a Phase contrast flow 
650 4 |a Stroke volume 
650 4 |a Validation study 
650 4 |a Ventricular function 
700 1 |a Wald, Rachel  |e VerfasserIn  |4 aut 
700 1 |a Wintersperger, Bernd  |d 1967-  |e VerfasserIn  |0 (DE-588)120600536  |0 (DE-627)704864665  |0 (DE-576)292294808  |4 aut 
700 1 |a Jimenez-Juan, Laura  |e VerfasserIn  |4 aut 
700 1 |a Deva, Djeven  |e VerfasserIn  |4 aut 
700 1 |a Crean, Andrew M.  |e VerfasserIn  |4 aut 
700 1 |a Nguyen, Elsie  |e VerfasserIn  |4 aut 
700 1 |a Paul, Narinder S.  |e VerfasserIn  |4 aut 
700 1 |a Ley, Sebastian  |d 1974-  |e VerfasserIn  |0 (DE-588)123561256  |0 (DE-627)706346858  |0 (DE-576)293766835  |4 aut 
773 0 8 |i Enthalten in  |a Canadian Association of Radiologists  |t Canadian Association of Radiologists journal  |d Thousand Oaks, CA : Sage Publications Ltd, 1994  |g 64(2013), 3, Seite 213-219  |h Online-Ressource  |w (DE-627)341359610  |w (DE-600)2068691-2  |w (DE-576)27387084X  |x 1488-2361  |7 nnas 
773 1 8 |g volume:64  |g year:2013  |g number:3  |g pages:213-219  |g extent:7  |a Accuracy of right and left ventricular functional assessment by short-axis vs axial cine steady-state free-precession magnetic resonance imaging intrapatient correlation with main pulmonary artery and ascending aorta phase-contrast flow measurements 
856 4 0 |u https://doi.org/10.1016/j.carj.2011.12.016  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20210325 
993 |a Article 
994 |a 2013 
998 |g 123561256  |a Ley, Sebastian  |m 123561256:Ley, Sebastian  |p 9  |y j 
999 |a KXP-PPN1752417828  |e 3894263830 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"origin":[{"dateIssuedKey":"1994","publisher":"Sage Publications Ltd ; Canadian Association of Radiologists ; Elsevier","dateIssuedDisp":"1994-","publisherPlace":"Thousand Oaks, CA ; Québec ; New York, NY [u.a.]"}],"id":{"issn":["1488-2361"],"zdb":["2068691-2"],"eki":["341359610"]},"titleTranslated":[{"translated":"Journal de l'Association Canadienne des Radiologistes"}],"pubHistory":["Nachgewiesen 45.1994 -"],"part":{"text":"64(2013), 3, Seite 213-219","volume":"64","extent":"7","year":"2013","pages":"213-219","issue":"3"},"titleAlt":[{"title":"CARJ"},{"title":"CAR journal"},{"title":"The journal of the Canadian Association of Radiologists"},{"title":"The Journal of the Canadian Association of Radiologists"},{"title":"Canadian Association of Radiologists journal"},{"title":"Journal"}],"disp":"Canadian Association of RadiologistsCanadian Association of Radiologists journal","note":["Gesehen am 26.09.25"],"type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng","fre"],"corporate":[{"roleDisplay":"VerfasserIn","display":"Canadian Association of Radiologists","role":"aut"}],"recId":"341359610","title":[{"title_sort":"Canadian Association of Radiologists journal","title":"Canadian Association of Radiologists journal","subtitle":" = Journal de l'Association Canadienne des Radiologistes"}]}],"physDesc":[{"extent":"7 S."}],"name":{"displayForm":["Susan H. James, MD, Rachel Wald, MD, Bernd J. Wintersperger, MD, Laura Jimenez-Juan, MD, Djeven Deva, MD, Andrew M. Crean, MD, Elsie Nguyen, MD, Narinder S. Paul, MD, Sebastian Ley, MD"]},"id":{"eki":["1752417828"],"doi":["10.1016/j.carj.2011.12.016"]},"origin":[{"dateIssuedDisp":"August 1, 2013","dateIssuedKey":"2013"}],"recId":"1752417828","language":["eng"],"note":["Gesehen am 25.03.2021"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"person":[{"family":"James","given":"Susan H.","roleDisplay":"VerfasserIn","display":"James, Susan H.","role":"aut"},{"roleDisplay":"VerfasserIn","display":"Wald, Rachel","role":"aut","family":"Wald","given":"Rachel"},{"given":"Bernd","family":"Wintersperger","role":"aut","display":"Wintersperger, Bernd","roleDisplay":"VerfasserIn"},{"given":"Laura","family":"Jimenez-Juan","role":"aut","display":"Jimenez-Juan, Laura","roleDisplay":"VerfasserIn"},{"family":"Deva","given":"Djeven","display":"Deva, Djeven","roleDisplay":"VerfasserIn","role":"aut"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Crean, Andrew M.","given":"Andrew M.","family":"Crean"},{"family":"Nguyen","given":"Elsie","display":"Nguyen, Elsie","roleDisplay":"VerfasserIn","role":"aut"},{"display":"Paul, Narinder S.","roleDisplay":"VerfasserIn","role":"aut","family":"Paul","given":"Narinder S."},{"role":"aut","roleDisplay":"VerfasserIn","display":"Ley, Sebastian","given":"Sebastian","family":"Ley"}],"title":[{"title_sort":"Accuracy of right and left ventricular functional assessment by short-axis vs axial cine steady-state free-precession magnetic resonance imaging","title":"Accuracy of right and left ventricular functional assessment by short-axis vs axial cine steady-state free-precession magnetic resonance imaging","subtitle":"intrapatient correlation with main pulmonary artery and ascending aorta phase-contrast flow measurements"}]} 
SRT |a JAMESSUSANACCURACYOF1201