Assessment of intracranial collateral flow by using dynamic arterial spin labeling MRA and transcranial color-coded duplex ultrasound
Background and Purpose: To evaluate the potential of a new dynamic MRA sequence (DynAngio) based on arterial spin labeling for the assessment of intracranial collateral flow. Methods: Twelve patients with unilateral internal carotid artery obstruction were investigated. Different patterns of collate...
Gespeichert in:
| Hauptverfasser: | , , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
[1 June 2008]
|
| In: |
Stroke
Year: 2008, Jahrgang: 39, Heft: 6, Pages: 1894-1897 |
| ISSN: | 1524-4628 |
| DOI: | 10.1161/STROKEAHA.107.503482 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1161/STROKEAHA.107.503482 Verlag, lizenzpflichtig, Volltext: https://www.ahajournals.org/doi/10.1161/STROKEAHA.107.503482 |
| Verfasserangaben: | Fabrizio Sallustio, MD, Rolf Kern, MD, Matthias Günther, PhD, Kristina Szabo, MD, Martin Griebe, MD, Stephen Meairs, MD, Michael Hennerici, MD, and Achim Gass, MD |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1752582152 | ||
| 003 | DE-627 | ||
| 005 | 20230817081218.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 210326s2008 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1161/STROKEAHA.107.503482 |2 doi | |
| 035 | |a (DE-627)1752582152 | ||
| 035 | |a (DE-599)KXP1752582152 | ||
| 035 | |a (OCoLC)1341401480 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Sallustio, Fabrizio |d 1975- |e VerfasserIn |0 (DE-588)1230015361 |0 (DE-627)1752324544 |4 aut | |
| 245 | 1 | 0 | |a Assessment of intracranial collateral flow by using dynamic arterial spin labeling MRA and transcranial color-coded duplex ultrasound |c Fabrizio Sallustio, MD, Rolf Kern, MD, Matthias Günther, PhD, Kristina Szabo, MD, Martin Griebe, MD, Stephen Meairs, MD, Michael Hennerici, MD, and Achim Gass, MD |
| 264 | 1 | |c [1 June 2008] | |
| 300 | |b Illustrationen | ||
| 300 | |a 4 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 26.03.2021 | ||
| 520 | |a Background and Purpose: To evaluate the potential of a new dynamic MRA sequence (DynAngio) based on arterial spin labeling for the assessment of intracranial collateral flow. Methods: Twelve patients with unilateral internal carotid artery obstruction were investigated. Different patterns of collateral flow were compared between DynAngio, transcranial color-coded duplex ultrasound, and time-of-flight MRA.Results: There was a good agreement between the methods, with sensitivities between 80% and 90%. Small collateral vessels were detected more frequently with DynAngio compared to time-of-flight MRA. Conclusion: DynAngio provides anatomic and similar to transcranial color-coded duplex ultrasound functional information on collateral flow for the assessment of intracranial hemodynamics. | ||
| 700 | 1 | |a Kern, Rolf |d 1972- |e VerfasserIn |0 (DE-588)1025172248 |0 (DE-627)72138143X |0 (DE-576)370036476 |4 aut | |
| 700 | 1 | |a Günther, Matthias |e VerfasserIn |0 (DE-588)1262253667 |0 (DE-627)1809695406 |4 aut | |
| 700 | 1 | |a Szabo, Kristina |d 1970- |e VerfasserIn |0 (DE-588)120354993 |0 (DE-627)696594749 |0 (DE-576)292174942 |4 aut | |
| 700 | 1 | |a Griebe, Martin |d 1975- |e VerfasserIn |0 (DE-588)132614006 |0 (DE-627)524422168 |0 (DE-576)299257452 |4 aut | |
| 700 | 1 | |a Meairs, Stephen |d 1951- |e VerfasserIn |0 (DE-588)102747103X |0 (DE-627)729172929 |0 (DE-576)373246048 |4 aut | |
| 700 | 1 | |a Hennerici, Michael G. |d 1948- |e VerfasserIn |0 (DE-588)11587545X |0 (DE-627)077527704 |0 (DE-576)290126444 |4 aut | |
| 700 | 1 | |a Gass, Achim |d 1961- |e VerfasserIn |0 (DE-588)1025167171 |0 (DE-627)721356001 |0 (DE-576)370026632 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Stroke |d New York, NY : Association, 1970 |g 39(2008), 6 vom: Juni, Seite 1894-1897 |h Online-Ressource |w (DE-627)266879985 |w (DE-600)1467823-8 |w (DE-576)075145731 |x 1524-4628 |7 nnas |a Assessment of intracranial collateral flow by using dynamic arterial spin labeling MRA and transcranial color-coded duplex ultrasound |
| 773 | 1 | 8 | |g volume:39 |g year:2008 |g number:6 |g month:06 |g pages:1894-1897 |g extent:4 |a Assessment of intracranial collateral flow by using dynamic arterial spin labeling MRA and transcranial color-coded duplex ultrasound |
| 856 | 4 | 0 | |u https://doi.org/10.1161/STROKEAHA.107.503482 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://www.ahajournals.org/doi/10.1161/STROKEAHA.107.503482 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20210326 | ||
| 993 | |a Article | ||
| 994 | |a 2008 | ||
| 998 | |g 1025167171 |a Gass, Achim |m 1025167171:Gass, Achim |p 8 |y j | ||
| 998 | |g 11587545X |a Hennerici, Michael G. |m 11587545X:Hennerici, Michael G. |d 60000 |d 62700 |e 60000PH11587545X |e 62700PH11587545X |k 0/60000/ |k 1/60000/62700/ |p 7 | ||
| 998 | |g 102747103X |a Meairs, Stephen |m 102747103X:Meairs, Stephen |d 60000 |d 62700 |e 60000PM102747103X |e 62700PM102747103X |k 0/60000/ |k 1/60000/62700/ |p 6 | ||
| 998 | |g 132614006 |a Griebe, Martin |m 132614006:Griebe, Martin |d 60000 |d 62700 |e 60000PG132614006 |e 62700PG132614006 |k 0/60000/ |k 1/60000/62700/ |p 5 | ||
| 998 | |g 120354993 |a Szabo, Kristina |m 120354993:Szabo, Kristina |d 60000 |e 60000PS120354993 |k 0/60000/ |p 4 | ||
| 998 | |g 1262253667 |a Günther, Matthias |m 1262253667:Günther, Matthias |d 60000 |d 62700 |e 60000PG1262253667 |e 62700PG1262253667 |k 0/60000/ |k 1/60000/62700/ |p 3 | ||
| 998 | |g 1025172248 |a Kern, Rolf |m 1025172248:Kern, Rolf |d 60000 |d 62700 |e 60000PK1025172248 |e 62700PK1025172248 |k 0/60000/ |k 1/60000/62700/ |p 2 | ||
| 999 | |a KXP-PPN1752582152 |e 3894823097 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"relHost":[{"recId":"266879985","pubHistory":["1.1970 -"],"physDesc":[{"extent":"Online-Ressource"}],"id":{"eki":["266879985"],"issn":["1524-4628"],"zdb":["1467823-8"]},"disp":"Assessment of intracranial collateral flow by using dynamic arterial spin labeling MRA and transcranial color-coded duplex ultrasoundStroke","corporate":[{"role":"isb","display":"American Heart Association"}],"language":["eng"],"part":{"issue":"6","extent":"4","volume":"39","year":"2008","pages":"1894-1897","text":"39(2008), 6 vom: Juni, Seite 1894-1897"},"origin":[{"publisherPlace":"New York, NY ; Philadelphia, Pa.","dateIssuedDisp":"1970-","dateIssuedKey":"1970","publisher":"Association ; Lippincott Williams & Wilkins"}],"note":["Gesehen am 29.06.04"],"type":{"media":"Online-Ressource","bibl":"periodical"},"title":[{"title":"Stroke","subtitle":"journal of the American Heart Association","title_sort":"Stroke"}]}],"id":{"eki":["1752582152"],"doi":["10.1161/STROKEAHA.107.503482"]},"recId":"1752582152","name":{"displayForm":["Fabrizio Sallustio, MD, Rolf Kern, MD, Matthias Günther, PhD, Kristina Szabo, MD, Martin Griebe, MD, Stephen Meairs, MD, Michael Hennerici, MD, and Achim Gass, MD"]},"physDesc":[{"extent":"4 S.","noteIll":"Illustrationen"}],"language":["eng"],"origin":[{"dateIssuedDisp":"[1 June 2008]","dateIssuedKey":"2008"}],"note":["Gesehen am 26.03.2021"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"title":[{"title":"Assessment of intracranial collateral flow by using dynamic arterial spin labeling MRA and transcranial color-coded duplex ultrasound","title_sort":"Assessment of intracranial collateral flow by using dynamic arterial spin labeling MRA and transcranial color-coded duplex ultrasound"}],"person":[{"role":"aut","given":"Fabrizio","family":"Sallustio","display":"Sallustio, Fabrizio"},{"display":"Kern, Rolf","family":"Kern","role":"aut","given":"Rolf"},{"given":"Matthias","role":"aut","family":"Günther","display":"Günther, Matthias"},{"family":"Szabo","display":"Szabo, Kristina","role":"aut","given":"Kristina"},{"display":"Griebe, Martin","family":"Griebe","given":"Martin","role":"aut"},{"display":"Meairs, Stephen","family":"Meairs","given":"Stephen","role":"aut"},{"role":"aut","given":"Michael G.","family":"Hennerici","display":"Hennerici, Michael G."},{"display":"Gass, Achim","family":"Gass","role":"aut","given":"Achim"}]} | ||
| SRT | |a SALLUSTIOFASSESSMENT1200 | ||