Moritz Waldecker, Dr Med Dent/Stefan Rues, Dipl-Ing/Charlotte Trebing, Dr Med Dent/Rouven Behnisch, MSc/Peter Rammelsberg, Prof Dr Med Dent/Wolfgang Bömicke, PD Dr Med Dent, MSc: Purpose: To investigate the effect of training on scanning accuracy of complete arch scans (CAS) performed - by first-t...
Gespeichert in:
| Hauptverfasser: | , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
2021
|
| In: |
The international journal of prosthodontics
Year: 2021, Jahrgang: 34, Pages: 27-36 |
| ISSN: | 1942-4426 |
| DOI: | 10.11607/ijp.6940 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.11607/ijp.6940 Verlag, lizenzpflichtig, Volltext: http://quintpub.com/journals/ijp/abstract.php?iss2_id=1723&article_id=21003#.YGRMTz9CQ2w |
| Verfasserangaben: | Moritz Waldecker, Dr Med Dent/ Stefan Rues, Dipl-Ing/ Charlotte Trebing, Dr Med Dent/ Rouven Behnisch, MSc/ Peter Rammelsberg, Prof Dr Med Dent/ Wolfgang Bömicke, PD Dr Med Dent, MSc |
MARC
| LEADER | 00000caa a22000002c 4500 | ||
|---|---|---|---|
| 001 | 1752961463 | ||
| 003 | DE-627 | ||
| 005 | 20220819152332.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 210331s2021 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.11607/ijp.6940 |2 doi | |
| 035 | |a (DE-627)1752961463 | ||
| 035 | |a (DE-599)KXP1752961463 | ||
| 035 | |a (OCoLC)1341402573 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Waldecker, Moritz |d 1986- |e VerfasserIn |0 (DE-588)114780172X |0 (DE-627)1007199024 |0 (DE-576)496051652 |4 aut | |
| 245 | 1 | 0 | |a Effects of training on the execution of complete-arch scans |b Part 2: scanning accuracy |c Moritz Waldecker, Dr Med Dent/ Stefan Rues, Dipl-Ing/ Charlotte Trebing, Dr Med Dent/ Rouven Behnisch, MSc/ Peter Rammelsberg, Prof Dr Med Dent/ Wolfgang Bömicke, PD Dr Med Dent, MSc |
| 246 | 3 | 0 | |a two |
| 264 | 1 | |c 2021 | |
| 300 | |a 10 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 10.09.2021 | ||
| 520 | |a Moritz Waldecker, Dr Med Dent/Stefan Rues, Dipl-Ing/Charlotte Trebing, Dr Med Dent/Rouven Behnisch, MSc/Peter Rammelsberg, Prof Dr Med Dent/Wolfgang Bömicke, PD Dr Med Dent, MSc: Purpose: To investigate the effect of training on scanning accuracy of complete arch scans (CAS) performed - by first-time users, with a distinction made between specific training (repeated performance of CAS) and - nonspecific training (simple use of an intraoral optical scanner for a sextant scan in the context of a CAD/CAM teaching module). Materials and Methods: A total of 36 students with no experience in intraoral - scanning were randomized into three groups (n = 12 per group) according to the number of CAS sessions: - three sessions (3S), two sessions (2S), and one session (1S). Each student had to perform 10 CAS per scanning - session. Sessions were scheduled at T<sub>0</sub>, T<sub>1</sub>, and T<sub>2</sub> for group 3S; at T<sub>0</sub> and T<sub>2</sub> for group 2S; and at T<sub>2</sub> for - group 1S. Before the final scanning session in each group (ie, the first scanning session in group 1S), the - students completed a CAD/CAM teaching module, which included fabrication of a monolithic crown in a - fully digital chairside workflow. Results: In all groups, repeated CAS resulted in improved scanning accuracy. - Participation in the CAD/CAM module had a positive effect on initial accuracy for CAS. Mean absolute - deviations in cross-arch distance were 84 μm (T<sub>0</sub>), 68 μm (T<sub>1</sub>), and 63 μm (T<sub>2</sub>) for group 3S; 79 μm (T<sub>0</sub>) and - 61 μm (T<sub>2</sub>) for group 2S; and 67 μm (T<sub>2</sub>) for group 1S. Conclusion: To perform CAS with the best possible - accuracy, specific training is highly recommended. In addition, nonspecific training leads to an improvement - in initial scanning accuracy. | ||
| 700 | 1 | |a Rues, Stefan |e VerfasserIn |0 (DE-588)1054444927 |0 (DE-627)792098331 |0 (DE-576)410292168 |4 aut | |
| 700 | 1 | |a Trebing, Charlotte Theresa |e VerfasserIn |0 (DE-588)1225686970 |0 (DE-627)1745534075 |4 aut | |
| 700 | 1 | |a Behnisch, Rouven |d 1990- |e VerfasserIn |0 (DE-588)1191206238 |0 (DE-627)1669619265 |4 aut | |
| 700 | 1 | |a Rammelsberg, Peter |d 1959- |e VerfasserIn |0 (DE-588)122469836 |0 (DE-627)705920836 |0 (DE-576)293285640 |4 aut | |
| 700 | 1 | |a Bömicke, Wolfgang |d 1981- |e VerfasserIn |0 (DE-588)1015022146 |0 (DE-627)668338792 |0 (DE-576)349947651 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t The international journal of prosthodontics |d Batavia : Quintessence Publishing, 1988 |g 34(2021) vom: Jan., Seite 27-36 |h Online-Ressource |w (DE-627)331254506 |w (DE-600)2050828-1 |w (DE-576)094477604 |x 1942-4426 |7 nnas |a Effects of training on the execution of complete-arch scans Part 2: scanning accuracy |
| 773 | 1 | 8 | |g volume:34 |g year:2021 |g month:01/2$ |g pages:27-36 |g extent:10 |a Effects of training on the execution of complete-arch scans Part 2: scanning accuracy |
| 856 | 4 | 0 | |u https://doi.org/10.11607/ijp.6940 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u http://quintpub.com/journals/ijp/abstract.php?iss2_id=1723&article_id=21003#.YGRMTz9CQ2w |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20210331 | ||
| 993 | |a Article | ||
| 994 | |a 2021 | ||
| 998 | |g 1015022146 |a Bömicke, Wolfgang |m 1015022146:Bömicke, Wolfgang |d 910000 |d 910800 |d 50000 |e 910000PB1015022146 |e 910800PB1015022146 |e 50000PB1015022146 |k 0/910000/ |k 1/910000/910800/ |k 0/50000/ |p 6 |y j | ||
| 998 | |g 122469836 |a Rammelsberg, Peter |m 122469836:Rammelsberg, Peter |d 910000 |d 910800 |e 910000PR122469836 |e 910800PR122469836 |k 0/910000/ |k 1/910000/910800/ |p 5 | ||
| 998 | |g 1191206238 |a Behnisch, Rouven |m 1191206238:Behnisch, Rouven |d 910000 |d 999701 |e 910000PB1191206238 |e 999701PB1191206238 |k 0/910000/ |k 1/910000/999701/ |p 4 | ||
| 998 | |g 1225686970 |a Trebing, Charlotte Theresa |m 1225686970:Trebing, Charlotte Theresa |d 910000 |d 910800 |e 910000PT1225686970 |e 910800PT1225686970 |k 0/910000/ |k 1/910000/910800/ |p 3 | ||
| 998 | |g 1054444927 |a Rues, Stefan |m 1054444927:Rues, Stefan |d 910000 |d 910800 |e 910000PR1054444927 |e 910800PR1054444927 |k 0/910000/ |k 1/910000/910800/ |p 2 | ||
| 998 | |g 114780172X |a Waldecker, Moritz |m 114780172X:Waldecker, Moritz |d 910000 |d 910800 |e 910000PW114780172X |e 910800PW114780172X |k 0/910000/ |k 1/910000/910800/ |p 1 |x j | ||
| 999 | |a KXP-PPN1752961463 |e 389950951X | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"recId":"1752961463","id":{"doi":["10.11607/ijp.6940"],"eki":["1752961463"]},"title":[{"subtitle":"Part 2: scanning accuracy","title_sort":"Effects of training on the execution of complete-arch scans","title":"Effects of training on the execution of complete-arch scans"}],"note":["Gesehen am 10.09.2021"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"origin":[{"dateIssuedKey":"2021","dateIssuedDisp":"2021"}],"language":["eng"],"person":[{"family":"Waldecker","roleDisplay":"VerfasserIn","display":"Waldecker, Moritz","role":"aut","given":"Moritz"},{"given":"Stefan","display":"Rues, Stefan","role":"aut","family":"Rues","roleDisplay":"VerfasserIn"},{"given":"Charlotte Theresa","role":"aut","display":"Trebing, Charlotte Theresa","roleDisplay":"VerfasserIn","family":"Trebing"},{"role":"aut","display":"Behnisch, Rouven","given":"Rouven","family":"Behnisch","roleDisplay":"VerfasserIn"},{"given":"Peter","display":"Rammelsberg, Peter","role":"aut","roleDisplay":"VerfasserIn","family":"Rammelsberg"},{"family":"Bömicke","roleDisplay":"VerfasserIn","role":"aut","display":"Bömicke, Wolfgang","given":"Wolfgang"}],"name":{"displayForm":["Moritz Waldecker, Dr Med Dent/ Stefan Rues, Dipl-Ing/ Charlotte Trebing, Dr Med Dent/ Rouven Behnisch, MSc/ Peter Rammelsberg, Prof Dr Med Dent/ Wolfgang Bömicke, PD Dr Med Dent, MSc"]},"physDesc":[{"extent":"10 S."}],"relHost":[{"corporate":[{"roleDisplay":"Herausgebendes Organ","display":"Deutsche Gesellschaft für Prothetische Zahnmedizin und Biomaterialien","role":"isb"}],"pubHistory":["1.1988 -"],"recId":"331254506","note":["Gesehen am 26.03.25"],"disp":"Effects of training on the execution of complete-arch scans Part 2: scanning accuracyThe international journal of prosthodontics","id":{"eki":["331254506"],"zdb":["2050828-1"],"issn":["1942-4426"]},"title":[{"title":"The international journal of prosthodontics","title_sort":"international journal of prosthodontics","subtitle":"bridging the gap between science and clinical practice : official journal of the International College of Prosthodontists"}],"physDesc":[{"extent":"Online-Ressource"}],"part":{"year":"2021","extent":"10","pages":"27-36","text":"34(2021) vom: Jan., Seite 27-36","volume":"34"},"origin":[{"publisher":"Quintessence Publishing","publisherPlace":"Batavia","dateIssuedKey":"1988","dateIssuedDisp":"1988-"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng"]}]} | ||
| SRT | |a WALDECKERMEFFECTSOFT2021 | ||