A longitudinal study of Type-B aortic dissection and endovascular repair scenarios: computational analyses

Conservative medical treatment is commonly first recommended for patients with uncomplicated Type-B aortic dissection (AD). However, if dissection-related complications occur, endovascular repair or open surgery is performed. Here we establish computational models of AD based on radiological three-d...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Chen, Duanduan (VerfasserIn) , Müller-Eschner, Matthias (VerfasserIn) , Kotelis, Drosos (VerfasserIn) , Böckler, Dittmar (VerfasserIn) , Ventikos, Yiannis (VerfasserIn) , Tengg-Kobligk, Hendrik von (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 27 February 2013
In: Medical engineering & physics
Year: 2013, Jahrgang: 35, Heft: 9, Pages: 1321-1330
ISSN:1873-4030
DOI:10.1016/j.medengphy.2013.02.006
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.medengphy.2013.02.006
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S1350453313000532
Volltext
Verfasserangaben:Duanduan Chen, Matthias Müller-Eschner, Drosos Kotelis, Dittmar Böckler, Yiannis Ventikos, Hendrik von Tengg-Kobligk

MARC

LEADER 00000caa a2200000 c 4500
001 175320237X
003 DE-627
005 20230426165444.0
007 cr uuu---uuuuu
008 210406s2013 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.medengphy.2013.02.006  |2 doi 
035 |a (DE-627)175320237X 
035 |a (DE-599)KXP175320237X 
035 |a (OCoLC)1341403450 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Chen, Duanduan  |e VerfasserIn  |0 (DE-588)1230833838  |0 (DE-627)1753200423  |4 aut 
245 1 2 |a A longitudinal study of Type-B aortic dissection and endovascular repair scenarios  |b computational analyses  |c Duanduan Chen, Matthias Müller-Eschner, Drosos Kotelis, Dittmar Böckler, Yiannis Ventikos, Hendrik von Tengg-Kobligk 
264 1 |c 27 February 2013 
300 |a 6 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 06.04.2021 
520 |a Conservative medical treatment is commonly first recommended for patients with uncomplicated Type-B aortic dissection (AD). However, if dissection-related complications occur, endovascular repair or open surgery is performed. Here we establish computational models of AD based on radiological three-dimensional images of a patient at initial presentation and after 4-years of best medical treatment (BMT). Computational fluid dynamics analyses are performed to quantitatively investigate the hemodynamic features of AD. Entry and re-entries (functioning as entries and outlets) are identified in the initial and follow-up models, and obvious variations of the inter-luminal flow exchange are revealed. Computational studies indicate that the reduction of blood pressure in BMT patients lowers pressure and wall shear stress in the thoracic aorta in general, and flattens the pressure distribution on the outer wall of the dissection, potentially reducing the progressive enlargement of the false lumen. Finally, scenario studies of endovascular aortic repair are conducted. The results indicate that, for patients with multiple tears, stent-grafts occluding all re-entries would be required to effectively reduce inter-luminal blood communication and thus induce thrombosis in the false lumen. This implicates that computational flow analyses may identify entries and relevant re-entries between true and false lumen and potentially assist in stent-graft planning. 
650 4 |a Aorta 
650 4 |a Computational fluid dynamics 
650 4 |a Dissection 
650 4 |a Hemodynamics 
650 4 |a Stent-graft 
700 1 |a Müller-Eschner, Matthias  |d 1981-  |e VerfasserIn  |0 (DE-588)138904022  |0 (DE-627)703146246  |0 (DE-576)30952122X  |4 aut 
700 1 |a Kotelis, Drosos  |d 1981-  |e VerfasserIn  |0 (DE-588)133375862  |0 (DE-627)544033671  |0 (DE-576)276111303  |4 aut 
700 1 |a Böckler, Dittmar  |d 1966-  |e VerfasserIn  |0 (DE-588)1032367881  |0 (DE-627)738382868  |0 (DE-576)173503969  |4 aut 
700 1 |a Ventikos, Yiannis  |e VerfasserIn  |4 aut 
700 1 |a Tengg-Kobligk, Hendrik von  |d 1972-  |e VerfasserIn  |0 (DE-588)129455733  |0 (DE-627)397663188  |0 (DE-576)297668501  |4 aut 
773 0 8 |i Enthalten in  |t Medical engineering & physics  |d Amsterdam [u.a.] : Elsevier Science, 1994  |g 35(2013), 9, Seite 1321-1330  |h Online-Ressource  |w (DE-627)320592332  |w (DE-600)2019106-6  |w (DE-576)259485039  |x 1873-4030  |7 nnas  |a A longitudinal study of Type-B aortic dissection and endovascular repair scenarios computational analyses 
773 1 8 |g volume:35  |g year:2013  |g number:9  |g pages:1321-1330  |g extent:6  |a A longitudinal study of Type-B aortic dissection and endovascular repair scenarios computational analyses 
856 4 0 |u https://doi.org/10.1016/j.medengphy.2013.02.006  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S1350453313000532  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20210406 
993 |a Article 
994 |a 2013 
998 |g 129455733  |a Tengg-Kobligk, Hendrik von  |m 129455733:Tengg-Kobligk, Hendrik von  |d 50000  |e 50000PT129455733  |k 0/50000/  |p 6  |y j 
998 |g 1032367881  |a Böckler, Dittmar  |m 1032367881:Böckler, Dittmar  |d 910000  |d 910200  |e 910000PB1032367881  |e 910200PB1032367881  |k 0/910000/  |k 1/910000/910200/  |p 4 
998 |g 133375862  |a Kotelis, Drosos  |m 133375862:Kotelis, Drosos  |d 910000  |d 910200  |e 910000PK133375862  |e 910200PK133375862  |k 0/910000/  |k 1/910000/910200/  |p 3 
998 |g 138904022  |a Müller-Eschner, Matthias  |m 138904022:Müller-Eschner, Matthias  |d 910000  |d 911400  |e 910000PM138904022  |e 911400PM138904022  |k 0/910000/  |k 1/910000/911400/  |p 2 
999 |a KXP-PPN175320237X  |e 3902190310 
BIB |a Y 
SER |a journal 
JSO |a {"note":["Gesehen am 06.04.2021"],"origin":[{"dateIssuedKey":"2013","dateIssuedDisp":"27 February 2013"}],"relHost":[{"id":{"eki":["320592332"],"zdb":["2019106-6"],"issn":["1873-4030"]},"language":["eng"],"recId":"320592332","pubHistory":["16.1994 -"],"origin":[{"publisher":"Elsevier Science","dateIssuedDisp":"1994-","dateIssuedKey":"1994","publisherPlace":"Amsterdam [u.a.]"}],"note":["Gesehen am 19.12.2019","Fortsetzung der Druck-Ausgabe"],"physDesc":[{"extent":"Online-Ressource"}],"disp":"A longitudinal study of Type-B aortic dissection and endovascular repair scenarios computational analysesMedical engineering & physics","title":[{"title_sort":"Medical engineering & physics","subtitle":"official publication of the Institution of Physics and Engineering in Medicine (IPEM)","title":"Medical engineering & physics"}],"part":{"year":"2013","pages":"1321-1330","text":"35(2013), 9, Seite 1321-1330","volume":"35","extent":"6","issue":"9"},"type":{"media":"Online-Ressource","bibl":"periodical"}}],"recId":"175320237X","language":["eng"],"name":{"displayForm":["Duanduan Chen, Matthias Müller-Eschner, Drosos Kotelis, Dittmar Böckler, Yiannis Ventikos, Hendrik von Tengg-Kobligk"]},"type":{"bibl":"article-journal","media":"Online-Ressource"},"physDesc":[{"extent":"6 S."}],"id":{"doi":["10.1016/j.medengphy.2013.02.006"],"eki":["175320237X"]},"title":[{"subtitle":"computational analyses","title":"A longitudinal study of Type-B aortic dissection and endovascular repair scenarios","title_sort":"longitudinal study of Type-B aortic dissection and endovascular repair scenarios"}],"person":[{"family":"Chen","role":"aut","display":"Chen, Duanduan","given":"Duanduan"},{"role":"aut","display":"Müller-Eschner, Matthias","given":"Matthias","family":"Müller-Eschner"},{"family":"Kotelis","display":"Kotelis, Drosos","given":"Drosos","role":"aut"},{"family":"Böckler","role":"aut","display":"Böckler, Dittmar","given":"Dittmar"},{"family":"Ventikos","display":"Ventikos, Yiannis","given":"Yiannis","role":"aut"},{"family":"Tengg-Kobligk","given":"Hendrik von","display":"Tengg-Kobligk, Hendrik von","role":"aut"}]} 
SRT |a CHENDUANDULONGITUDIN2720