Comparison of single-scanner single-protocol quantitative ADC measurements to ADC ratios to detect clinically significant prostate cancer

Background - Mean ADC has high predictive value for the presence of clinically significant prostate cancer (sPC). Measurement variability is introduced by different scanners, protocols, intra-and inter-patient variation. Internal calibration by ADC ratios can address such fluctuations however can po...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Wang, Xianfeng (VerfasserIn) , Hielscher, Thomas (VerfasserIn) , Radtke, Jan Philipp (VerfasserIn) , Görtz, Magdalena (VerfasserIn) , Schütz, Viktoria (VerfasserIn) , Kuder, Tristan Anselm (VerfasserIn) , Gnirs, Regula (VerfasserIn) , Schwab, Constantin (VerfasserIn) , Stenzinger, Albrecht (VerfasserIn) , Hohenfellner, Markus (VerfasserIn) , Schlemmer, Heinz-Peter (VerfasserIn) , Bonekamp, David (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 13 January 2021
In: European journal of radiology
Year: 2021, Jahrgang: 136, Pages: 1-9
ISSN:1872-7727
DOI:10.1016/j.ejrad.2021.109538
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.ejrad.2021.109538
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0720048X21000188
Volltext
Verfasserangaben:Xianfeng Wang, Thomas Hielscher, Jan Philipp Radtke, Magdalena Görtz, Viktoria Schütz, Tristan Anselm Kuder, Regula Gnirs, Constantin Schwab, Albrecht Stenzinger, Markus Hohenfellner, Heinz-Peter Schlemmer, David Bonekamp

MARC

LEADER 00000caa a2200000 c 4500
001 1753227836
003 DE-627
005 20220819154859.0
007 cr uuu---uuuuu
008 210407s2021 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.ejrad.2021.109538  |2 doi 
035 |a (DE-627)1753227836 
035 |a (DE-599)KXP1753227836 
035 |a (OCoLC)1341403427 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Wang, Xianfeng  |d 1986-  |e VerfasserIn  |0 (DE-588)1230998098  |0 (DE-627)1753333954  |4 aut 
245 1 0 |a Comparison of single-scanner single-protocol quantitative ADC measurements to ADC ratios to detect clinically significant prostate cancer  |c Xianfeng Wang, Thomas Hielscher, Jan Philipp Radtke, Magdalena Görtz, Viktoria Schütz, Tristan Anselm Kuder, Regula Gnirs, Constantin Schwab, Albrecht Stenzinger, Markus Hohenfellner, Heinz-Peter Schlemmer, David Bonekamp 
264 1 |c 13 January 2021 
300 |a 9 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 08.04.2021 
520 |a Background - Mean ADC has high predictive value for the presence of clinically significant prostate cancer (sPC). Measurement variability is introduced by different scanners, protocols, intra-and inter-patient variation. Internal calibration by ADC ratios can address such fluctuations however can potentially lower the biological value of quantitative ADC determination by being sensitive to deviations in reference tissue signal. - Purpose - To better understand the predictive value of quantitative ADC measurements in comparison to internal reference ratios when measured in a single scanner, single protocol setup. - Materials and methods - 284 consecutive patients who underwent 3T MRI on a single scanner followed by MRI-transrectal ultrasound fusion biopsy were included. A board-certified radiologist retrospectively reviewed all MRIs blinded to clinical information and placed regions of interest (ROI) on all focal lesions and the following reference regions: normal-appearing peripheral zone (PZNL) and transition zone (TZNL), the urinary bladder (BLA), and right and left internal obturator muscle (RIOM, LIOM). ROI-based mean ADC and ADC ratios to the reference regions were compared regarding their ability to predict the aggressiveness of prostate cancer. Spearman’s rank correlation coefficient was used to estimate the correlation between ADC parameters, Gleason score (GS) and ADC ratios. The primary endpoint was presence of sPC, defined as a GS ≥ 3+4. Univariable and multivariable logistic regression models were constructed to predict sPC. Receiver operating characteristics curves (ROC) were used for visualization; DeLong test was used to evaluate the differences of the area under the curve (AUC). Bias-corrected AUC values and corresponding 95 %-CI were calculated using bootstrapping with 100 bootstrap samples. - Results - After exclusion of patients who received prior treatment, 259 patients were included in the final cohort of which 220 harbored 351 MR lesions. Mean ADC and ADC ratios demonstrated a negative correlation with the GS. Mean ADC had the strongest correlation with ρ of -0.34, followed by ADCratioPZNL (ρ=-0.32). All ADC parameters except ADCratioLIOM (p=0.07) were associated with sPC p<0.05). Mean ADC and ADCratioPZNL had the highest ROC AUC of all parameters (0.68). Multivariable models with mean ADC improve predictive performance. - Conclusions - A highly standardized single-scanner mean ADC measurement could not be improved upon using any of the single ADC ratio parameters or combinations of these parameters in predicting the aggressiveness of prostate cancer. 
650 4 |a Apparent diffusion coefficient 
650 4 |a Gleason score 
650 4 |a Multiparametric MRI 
650 4 |a Prostate cancer 
700 1 |a Hielscher, Thomas  |e VerfasserIn  |0 (DE-588)1159594791  |0 (DE-627)1022977768  |0 (DE-576)50506068X  |4 aut 
700 1 |a Radtke, Jan Philipp  |d 1985-  |e VerfasserIn  |0 (DE-588)1020328290  |0 (DE-627)688118089  |0 (DE-576)360178170  |4 aut 
700 1 |a Görtz, Magdalena  |d 1992-  |e VerfasserIn  |0 (DE-588)1166813657  |0 (DE-627)1030681392  |0 (DE-576)510916600  |4 aut 
700 1 |a Schütz, Viktoria  |e VerfasserIn  |0 (DE-588)1183860021  |0 (DE-627)1663385335  |4 aut 
700 1 |a Kuder, Tristan Anselm  |e VerfasserIn  |0 (DE-588)14203911X  |0 (DE-627)704126338  |0 (DE-576)326749675  |4 aut 
700 1 |a Gnirs, Regula  |e VerfasserIn  |0 (DE-588)1230998284  |0 (DE-627)1753334381  |4 aut 
700 1 |a Schwab, Constantin  |d 1992-  |e VerfasserIn  |0 (DE-588)1106892291  |0 (DE-627)863243045  |0 (DE-576)474954269  |4 aut 
700 1 |a Stenzinger, Albrecht  |e VerfasserIn  |0 (DE-588)139606106  |0 (DE-627)703395238  |0 (DE-576)312432755  |4 aut 
700 1 |a Hohenfellner, Markus  |d 1958-  |e VerfasserIn  |0 (DE-588)133862518  |0 (DE-627)557857988  |0 (DE-576)300155263  |4 aut 
700 1 |a Schlemmer, Heinz-Peter  |d 1961-  |e VerfasserIn  |0 (DE-588)1025559967  |0 (DE-627)722927142  |0 (DE-576)17334805X  |4 aut 
700 1 |a Bonekamp, David  |d 1977-  |e VerfasserIn  |0 (DE-588)128868104  |0 (DE-627)383668581  |0 (DE-576)297371797  |4 aut 
773 0 8 |i Enthalten in  |t European journal of radiology  |d Amsterdam [u.a.] : Elsevier Science, 1990  |g 136(2021), Artikel-ID 109538, Seite 1-9  |h Online-Ressource  |w (DE-627)32044483X  |w (DE-600)2005350-2  |w (DE-576)099718138  |x 1872-7727  |7 nnas  |a Comparison of single-scanner single-protocol quantitative ADC measurements to ADC ratios to detect clinically significant prostate cancer 
773 1 8 |g volume:136  |g year:2021  |g elocationid:109538  |g pages:1-9  |g extent:9  |a Comparison of single-scanner single-protocol quantitative ADC measurements to ADC ratios to detect clinically significant prostate cancer 
856 4 0 |u https://doi.org/10.1016/j.ejrad.2021.109538  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0720048X21000188  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20210407 
993 |a Article 
994 |a 2021 
998 |g 1230998098  |a Wang, Xianfeng  |m 1230998098:Wang, Xianfeng  |d 50000  |e 50000PW1230998098  |k 0/50000/  |p 1  |x j 
998 |g 128868104  |a Bonekamp, David  |m 128868104:Bonekamp, David  |d 50000  |e 50000PB128868104  |k 0/50000/  |p 12  |y j 
998 |g 1025559967  |a Schlemmer, Heinz-Peter  |m 1025559967:Schlemmer, Heinz-Peter  |d 50000  |e 50000PS1025559967  |k 0/50000/  |p 11 
998 |g 133862518  |a Hohenfellner, Markus  |m 133862518:Hohenfellner, Markus  |d 910000  |d 910200  |e 910000PH133862518  |e 910200PH133862518  |k 0/910000/  |k 1/910000/910200/  |p 10 
998 |g 139606106  |a Stenzinger, Albrecht  |m 139606106:Stenzinger, Albrecht  |d 910000  |d 912000  |e 910000PS139606106  |e 912000PS139606106  |k 0/910000/  |k 1/910000/912000/  |p 9 
998 |g 1106892291  |a Schwab, Constantin  |m 1106892291:Schwab, Constantin  |d 910000  |d 912000  |e 910000PS1106892291  |e 912000PS1106892291  |k 0/910000/  |k 1/910000/912000/  |p 8 
998 |g 14203911X  |a Kuder, Tristan Anselm  |m 14203911X:Kuder, Tristan Anselm  |d 50000  |e 50000PK14203911X  |k 0/50000/  |p 6 
998 |g 1183860021  |a Schütz, Viktoria  |m 1183860021:Schütz, Viktoria  |d 910000  |d 910200  |e 910000PS1183860021  |e 910200PS1183860021  |k 0/910000/  |k 1/910000/910200/  |p 5 
998 |g 1166813657  |a Görtz, Magdalena  |m 1166813657:Görtz, Magdalena  |d 910000  |d 910200  |e 910000PG1166813657  |e 910200PG1166813657  |k 0/910000/  |k 1/910000/910200/  |p 4 
998 |g 1020328290  |a Radtke, Jan Philipp  |m 1020328290:Radtke, Jan Philipp  |d 50000  |e 50000PR1020328290  |k 0/50000/  |p 3 
998 |g 1159594791  |a Hielscher, Thomas  |m 1159594791:Hielscher, Thomas  |d 140000  |e 140000PH1159594791  |k 0/140000/  |p 2 
999 |a KXP-PPN1753227836  |e 3902910135 
BIB |a Y 
SER |a journal 
JSO |a {"id":{"eki":["1753227836"],"doi":["10.1016/j.ejrad.2021.109538"]},"name":{"displayForm":["Xianfeng Wang, Thomas Hielscher, Jan Philipp Radtke, Magdalena Görtz, Viktoria Schütz, Tristan Anselm Kuder, Regula Gnirs, Constantin Schwab, Albrecht Stenzinger, Markus Hohenfellner, Heinz-Peter Schlemmer, David Bonekamp"]},"note":["Gesehen am 08.04.2021"],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"title":[{"title_sort":"Comparison of single-scanner single-protocol quantitative ADC measurements to ADC ratios to detect clinically significant prostate cancer","title":"Comparison of single-scanner single-protocol quantitative ADC measurements to ADC ratios to detect clinically significant prostate cancer"}],"person":[{"family":"Wang","given":"Xianfeng","role":"aut","display":"Wang, Xianfeng"},{"family":"Hielscher","role":"aut","given":"Thomas","display":"Hielscher, Thomas"},{"family":"Radtke","role":"aut","given":"Jan Philipp","display":"Radtke, Jan Philipp"},{"display":"Görtz, Magdalena","family":"Görtz","role":"aut","given":"Magdalena"},{"display":"Schütz, Viktoria","family":"Schütz","role":"aut","given":"Viktoria"},{"role":"aut","given":"Tristan Anselm","family":"Kuder","display":"Kuder, Tristan Anselm"},{"display":"Gnirs, Regula","given":"Regula","role":"aut","family":"Gnirs"},{"display":"Schwab, Constantin","family":"Schwab","given":"Constantin","role":"aut"},{"display":"Stenzinger, Albrecht","given":"Albrecht","role":"aut","family":"Stenzinger"},{"display":"Hohenfellner, Markus","given":"Markus","role":"aut","family":"Hohenfellner"},{"family":"Schlemmer","role":"aut","given":"Heinz-Peter","display":"Schlemmer, Heinz-Peter"},{"display":"Bonekamp, David","family":"Bonekamp","role":"aut","given":"David"}],"relHost":[{"titleAlt":[{"title":"EJR"}],"pubHistory":["Nachgewiesen 10.1990 -"],"part":{"volume":"136","text":"136(2021), Artikel-ID 109538, Seite 1-9","extent":"9","pages":"1-9","year":"2021"},"id":{"zdb":["2005350-2"],"eki":["32044483X"],"issn":["1872-7727"]},"origin":[{"publisher":"Elsevier Science","dateIssuedKey":"1990","dateIssuedDisp":"1990-","publisherPlace":"Amsterdam [u.a.]"}],"title":[{"subtitle":"EJR","title_sort":"European journal of radiology","title":"European journal of radiology"}],"note":["Gesehen am 05.02.20"],"type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng"],"recId":"32044483X","physDesc":[{"extent":"Online-Ressource"}],"disp":"Comparison of single-scanner single-protocol quantitative ADC measurements to ADC ratios to detect clinically significant prostate cancerEuropean journal of radiology"}],"origin":[{"dateIssuedKey":"2021","dateIssuedDisp":"13 January 2021"}],"physDesc":[{"extent":"9 S."}],"recId":"1753227836"} 
SRT |a WANGXIANFECOMPARISON1320