A preliminary study of fast virtual stent-graft deployment: application to Stanford type B aortic dissection
Aortic dissection is the result of blood intruding into the layers of the aortic wall creating a duplicate channel along the aortic course. This considerably changes aortic morphology and thereby alters blood flow, inducing severe pathological conditions. Endovascular stent-graft placement has becom...
Gespeichert in:
| Hauptverfasser: | , , , , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
January 1, 2013
|
| In: |
International journal of advanced robotic systems
Year: 2013, Jahrgang: 10, Heft: 3, Pages: 1-8 |
| ISSN: | 1729-8814 |
| DOI: | 10.5772/55269 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.5772/55269 |
| Verfasserangaben: | Duanduan Chen, Matthias Müller-Eschner, Fabian Rengier, Drosos Kotelis, Dittmar Böckler, Yiannis Ventikos, Yong Xu, Yanjun Zeng, Yuhua Peng and Hendrik von Tengg-Kobligk |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1753372933 | ||
| 003 | DE-627 | ||
| 005 | 20220819160410.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 210408s2013 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.5772/55269 |2 doi | |
| 035 | |a (DE-627)1753372933 | ||
| 035 | |a (DE-599)KXP1753372933 | ||
| 035 | |a (OCoLC)1341403886 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Chen, Duanduan |e VerfasserIn |0 (DE-588)1230833838 |0 (DE-627)1753200423 |4 aut | |
| 245 | 1 | 2 | |a A preliminary study of fast virtual stent-graft deployment |b application to Stanford type B aortic dissection |c Duanduan Chen, Matthias Müller-Eschner, Fabian Rengier, Drosos Kotelis, Dittmar Böckler, Yiannis Ventikos, Yong Xu, Yanjun Zeng, Yuhua Peng and Hendrik von Tengg-Kobligk |
| 264 | 1 | |c January 1, 2013 | |
| 300 | |a 8 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 08.04.2021 | ||
| 520 | |a Aortic dissection is the result of blood intruding into the layers of the aortic wall creating a duplicate channel along the aortic course. This considerably changes aortic morphology and thereby alters blood flow, inducing severe pathological conditions. Endovascular stent-graft placement has become an accepted treatment option for complicated Stanford type B aortic dissection. Stent-graft deployment aims to cover the primary entry, preventing most of the inflow to the false lumen, thereby promoting false lumen thrombosis and true lumen expansion. In recent years the application of this treatment has increased continuously. However, a fast and reasonable prediction for the released stent-graft and the resulting aortic remodelling prior to intervention is still lacking. In this paper, we propose a preliminary study on the fast virtual stent-graft deployment algorithm based on contact mechanics, spring analogy and deformable meshes. By virtually releasing a stent-graft in a patient-specific model of an aortic dissection type Stanford B, we simulate the interaction between the expanding stent-graft and the vessel wall (with low computational cost), and estimate the post-interventional configuration of the true lumen. This preliminary study can be finished within minutes and the results present good consistency with the post-interventional computed tomography angiography. It therefore confirms the feasibility and rationality of this algorithm, encouraging further research on this topic, which may provide more accurate results and could assist in medical decision-making. | ||
| 650 | 4 | |a Aortic Dissection | |
| 650 | 4 | |a Contact Mechanics | |
| 650 | 4 | |a Deformable Meshes | |
| 650 | 4 | |a Spring Analogy | |
| 650 | 4 | |a Stent-Graft | |
| 700 | 1 | |a Müller-Eschner, Matthias |d 1981- |e VerfasserIn |0 (DE-588)138904022 |0 (DE-627)703146246 |0 (DE-576)30952122X |4 aut | |
| 700 | 1 | |a Rengier, Fabian |d 1986- |e VerfasserIn |0 (DE-588)139065865 |0 (DE-627)608103284 |0 (DE-576)309935873 |4 aut | |
| 700 | 1 | |a Kotelis, Drosos |d 1981- |e VerfasserIn |0 (DE-588)133375862 |0 (DE-627)544033671 |0 (DE-576)276111303 |4 aut | |
| 700 | 1 | |a Böckler, Dittmar |d 1966- |e VerfasserIn |0 (DE-588)1032367881 |0 (DE-627)738382868 |0 (DE-576)173503969 |4 aut | |
| 700 | 1 | |a Ventikos, Yiannis |e VerfasserIn |4 aut | |
| 700 | 1 | |a Xu, Yong |e VerfasserIn |4 aut | |
| 700 | 1 | |a Zeng, Yanjun |e VerfasserIn |4 aut | |
| 700 | 1 | |a Peng, Yuhua |e VerfasserIn |4 aut | |
| 700 | 1 | |a Tengg-Kobligk, Hendrik von |d 1972- |e VerfasserIn |0 (DE-588)129455733 |0 (DE-627)397663188 |0 (DE-576)297668501 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t International journal of advanced robotic systems |d London : Sage Publishing, 2004 |g 10(2013), 3, Artikel-ID 154, Seite 1-8 |h Online-Ressource |w (DE-627)500017794 |w (DE-600)2202393-8 |w (DE-576)276559800 |x 1729-8814 |7 nnas |a A preliminary study of fast virtual stent-graft deployment application to Stanford type B aortic dissection |
| 773 | 1 | 8 | |g volume:10 |g year:2013 |g number:3 |g elocationid:154 |g pages:1-8 |g extent:8 |a A preliminary study of fast virtual stent-graft deployment application to Stanford type B aortic dissection |
| 856 | 4 | 0 | |u https://doi.org/10.5772/55269 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20210408 | ||
| 993 | |a Article | ||
| 994 | |a 2013 | ||
| 998 | |g 129455733 |a Tengg-Kobligk, Hendrik von |m 129455733:Tengg-Kobligk, Hendrik von |d 50000 |e 50000PT129455733 |k 0/50000/ |p 10 |y j | ||
| 998 | |g 1032367881 |a Böckler, Dittmar |m 1032367881:Böckler, Dittmar |d 910000 |d 910200 |e 910000PB1032367881 |e 910200PB1032367881 |k 0/910000/ |k 1/910000/910200/ |p 5 | ||
| 998 | |g 133375862 |a Kotelis, Drosos |m 133375862:Kotelis, Drosos |d 910000 |d 910200 |e 910000PK133375862 |e 910200PK133375862 |k 0/910000/ |k 1/910000/910200/ |p 4 | ||
| 998 | |g 139065865 |a Rengier, Fabian |m 139065865:Rengier, Fabian |d 910000 |d 911400 |e 910000PR139065865 |e 911400PR139065865 |k 0/910000/ |k 1/910000/911400/ |p 3 | ||
| 998 | |g 138904022 |a Müller-Eschner, Matthias |m 138904022:Müller-Eschner, Matthias |p 2 | ||
| 999 | |a KXP-PPN1753372933 |e 3903463299 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"relHost":[{"recId":"500017794","note":["Gesehen am 25.01.2017"],"origin":[{"publisher":"Sage Publishing ; Automation and Control Institute","dateIssuedDisp":"2004-","dateIssuedKey":"2004","publisherPlace":"London ; Vienna"}],"pubHistory":["1.2004 -"],"id":{"issn":["1729-8814"],"zdb":["2202393-8"],"eki":["500017794"]},"language":["eng"],"titleAlt":[{"title":"ARS"},{"title":"IJARS"}],"title":[{"title_sort":"International journal of advanced robotic systems","title":"International journal of advanced robotic systems"}],"part":{"issue":"3","volume":"10","extent":"8","text":"10(2013), 3, Artikel-ID 154, Seite 1-8","year":"2013","pages":"1-8"},"disp":"A preliminary study of fast virtual stent-graft deployment application to Stanford type B aortic dissectionInternational journal of advanced robotic systems","physDesc":[{"extent":"Online-Ressource"}],"type":{"bibl":"periodical","media":"Online-Ressource"}}],"recId":"1753372933","origin":[{"dateIssuedKey":"2013","dateIssuedDisp":"January 1, 2013"}],"note":["Gesehen am 08.04.2021"],"physDesc":[{"extent":"8 S."}],"id":{"eki":["1753372933"],"doi":["10.5772/55269"]},"title":[{"title_sort":"preliminary study of fast virtual stent-graft deployment","subtitle":"application to Stanford type B aortic dissection","title":"A preliminary study of fast virtual stent-graft deployment"}],"person":[{"family":"Chen","given":"Duanduan","display":"Chen, Duanduan","role":"aut"},{"role":"aut","given":"Matthias","display":"Müller-Eschner, Matthias","family":"Müller-Eschner"},{"display":"Rengier, Fabian","given":"Fabian","role":"aut","family":"Rengier"},{"given":"Drosos","display":"Kotelis, Drosos","role":"aut","family":"Kotelis"},{"family":"Böckler","display":"Böckler, Dittmar","given":"Dittmar","role":"aut"},{"role":"aut","given":"Yiannis","display":"Ventikos, Yiannis","family":"Ventikos"},{"family":"Xu","role":"aut","given":"Yong","display":"Xu, Yong"},{"given":"Yanjun","display":"Zeng, Yanjun","role":"aut","family":"Zeng"},{"role":"aut","given":"Yuhua","display":"Peng, Yuhua","family":"Peng"},{"display":"Tengg-Kobligk, Hendrik von","given":"Hendrik von","role":"aut","family":"Tengg-Kobligk"}],"language":["eng"],"name":{"displayForm":["Duanduan Chen, Matthias Müller-Eschner, Fabian Rengier, Drosos Kotelis, Dittmar Böckler, Yiannis Ventikos, Yong Xu, Yanjun Zeng, Yuhua Peng and Hendrik von Tengg-Kobligk"]},"type":{"bibl":"article-journal","media":"Online-Ressource"}} | ||
| SRT | |a CHENDUANDUPRELIMINAR1201 | ||