A preliminary study of fast virtual stent-graft deployment: application to Stanford type B aortic dissection

Aortic dissection is the result of blood intruding into the layers of the aortic wall creating a duplicate channel along the aortic course. This considerably changes aortic morphology and thereby alters blood flow, inducing severe pathological conditions. Endovascular stent-graft placement has becom...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Chen, Duanduan (VerfasserIn) , Müller-Eschner, Matthias (VerfasserIn) , Rengier, Fabian (VerfasserIn) , Kotelis, Drosos (VerfasserIn) , Böckler, Dittmar (VerfasserIn) , Ventikos, Yiannis (VerfasserIn) , Xu, Yong (VerfasserIn) , Zeng, Yanjun (VerfasserIn) , Peng, Yuhua (VerfasserIn) , Tengg-Kobligk, Hendrik von (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: January 1, 2013
In: International journal of advanced robotic systems
Year: 2013, Jahrgang: 10, Heft: 3, Pages: 1-8
ISSN:1729-8814
DOI:10.5772/55269
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.5772/55269
Volltext
Verfasserangaben:Duanduan Chen, Matthias Müller-Eschner, Fabian Rengier, Drosos Kotelis, Dittmar Böckler, Yiannis Ventikos, Yong Xu, Yanjun Zeng, Yuhua Peng and Hendrik von Tengg-Kobligk

MARC

LEADER 00000caa a2200000 c 4500
001 1753372933
003 DE-627
005 20220819160410.0
007 cr uuu---uuuuu
008 210408s2013 xx |||||o 00| ||eng c
024 7 |a 10.5772/55269  |2 doi 
035 |a (DE-627)1753372933 
035 |a (DE-599)KXP1753372933 
035 |a (OCoLC)1341403886 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Chen, Duanduan  |e VerfasserIn  |0 (DE-588)1230833838  |0 (DE-627)1753200423  |4 aut 
245 1 2 |a A preliminary study of fast virtual stent-graft deployment  |b application to Stanford type B aortic dissection  |c Duanduan Chen, Matthias Müller-Eschner, Fabian Rengier, Drosos Kotelis, Dittmar Böckler, Yiannis Ventikos, Yong Xu, Yanjun Zeng, Yuhua Peng and Hendrik von Tengg-Kobligk 
264 1 |c January 1, 2013 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 08.04.2021 
520 |a Aortic dissection is the result of blood intruding into the layers of the aortic wall creating a duplicate channel along the aortic course. This considerably changes aortic morphology and thereby alters blood flow, inducing severe pathological conditions. Endovascular stent-graft placement has become an accepted treatment option for complicated Stanford type B aortic dissection. Stent-graft deployment aims to cover the primary entry, preventing most of the inflow to the false lumen, thereby promoting false lumen thrombosis and true lumen expansion. In recent years the application of this treatment has increased continuously. However, a fast and reasonable prediction for the released stent-graft and the resulting aortic remodelling prior to intervention is still lacking. In this paper, we propose a preliminary study on the fast virtual stent-graft deployment algorithm based on contact mechanics, spring analogy and deformable meshes. By virtually releasing a stent-graft in a patient-specific model of an aortic dissection type Stanford B, we simulate the interaction between the expanding stent-graft and the vessel wall (with low computational cost), and estimate the post-interventional configuration of the true lumen. This preliminary study can be finished within minutes and the results present good consistency with the post-interventional computed tomography angiography. It therefore confirms the feasibility and rationality of this algorithm, encouraging further research on this topic, which may provide more accurate results and could assist in medical decision-making. 
650 4 |a Aortic Dissection 
650 4 |a Contact Mechanics 
650 4 |a Deformable Meshes 
650 4 |a Spring Analogy 
650 4 |a Stent-Graft 
700 1 |a Müller-Eschner, Matthias  |d 1981-  |e VerfasserIn  |0 (DE-588)138904022  |0 (DE-627)703146246  |0 (DE-576)30952122X  |4 aut 
700 1 |a Rengier, Fabian  |d 1986-  |e VerfasserIn  |0 (DE-588)139065865  |0 (DE-627)608103284  |0 (DE-576)309935873  |4 aut 
700 1 |a Kotelis, Drosos  |d 1981-  |e VerfasserIn  |0 (DE-588)133375862  |0 (DE-627)544033671  |0 (DE-576)276111303  |4 aut 
700 1 |a Böckler, Dittmar  |d 1966-  |e VerfasserIn  |0 (DE-588)1032367881  |0 (DE-627)738382868  |0 (DE-576)173503969  |4 aut 
700 1 |a Ventikos, Yiannis  |e VerfasserIn  |4 aut 
700 1 |a Xu, Yong  |e VerfasserIn  |4 aut 
700 1 |a Zeng, Yanjun  |e VerfasserIn  |4 aut 
700 1 |a Peng, Yuhua  |e VerfasserIn  |4 aut 
700 1 |a Tengg-Kobligk, Hendrik von  |d 1972-  |e VerfasserIn  |0 (DE-588)129455733  |0 (DE-627)397663188  |0 (DE-576)297668501  |4 aut 
773 0 8 |i Enthalten in  |t International journal of advanced robotic systems  |d London : Sage Publishing, 2004  |g 10(2013), 3, Artikel-ID 154, Seite 1-8  |h Online-Ressource  |w (DE-627)500017794  |w (DE-600)2202393-8  |w (DE-576)276559800  |x 1729-8814  |7 nnas  |a A preliminary study of fast virtual stent-graft deployment application to Stanford type B aortic dissection 
773 1 8 |g volume:10  |g year:2013  |g number:3  |g elocationid:154  |g pages:1-8  |g extent:8  |a A preliminary study of fast virtual stent-graft deployment application to Stanford type B aortic dissection 
856 4 0 |u https://doi.org/10.5772/55269  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20210408 
993 |a Article 
994 |a 2013 
998 |g 129455733  |a Tengg-Kobligk, Hendrik von  |m 129455733:Tengg-Kobligk, Hendrik von  |d 50000  |e 50000PT129455733  |k 0/50000/  |p 10  |y j 
998 |g 1032367881  |a Böckler, Dittmar  |m 1032367881:Böckler, Dittmar  |d 910000  |d 910200  |e 910000PB1032367881  |e 910200PB1032367881  |k 0/910000/  |k 1/910000/910200/  |p 5 
998 |g 133375862  |a Kotelis, Drosos  |m 133375862:Kotelis, Drosos  |d 910000  |d 910200  |e 910000PK133375862  |e 910200PK133375862  |k 0/910000/  |k 1/910000/910200/  |p 4 
998 |g 139065865  |a Rengier, Fabian  |m 139065865:Rengier, Fabian  |d 910000  |d 911400  |e 910000PR139065865  |e 911400PR139065865  |k 0/910000/  |k 1/910000/911400/  |p 3 
998 |g 138904022  |a Müller-Eschner, Matthias  |m 138904022:Müller-Eschner, Matthias  |p 2 
999 |a KXP-PPN1753372933  |e 3903463299 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"recId":"500017794","note":["Gesehen am 25.01.2017"],"origin":[{"publisher":"Sage Publishing ; Automation and Control Institute","dateIssuedDisp":"2004-","dateIssuedKey":"2004","publisherPlace":"London ; Vienna"}],"pubHistory":["1.2004 -"],"id":{"issn":["1729-8814"],"zdb":["2202393-8"],"eki":["500017794"]},"language":["eng"],"titleAlt":[{"title":"ARS"},{"title":"IJARS"}],"title":[{"title_sort":"International journal of advanced robotic systems","title":"International journal of advanced robotic systems"}],"part":{"issue":"3","volume":"10","extent":"8","text":"10(2013), 3, Artikel-ID 154, Seite 1-8","year":"2013","pages":"1-8"},"disp":"A preliminary study of fast virtual stent-graft deployment application to Stanford type B aortic dissectionInternational journal of advanced robotic systems","physDesc":[{"extent":"Online-Ressource"}],"type":{"bibl":"periodical","media":"Online-Ressource"}}],"recId":"1753372933","origin":[{"dateIssuedKey":"2013","dateIssuedDisp":"January 1, 2013"}],"note":["Gesehen am 08.04.2021"],"physDesc":[{"extent":"8 S."}],"id":{"eki":["1753372933"],"doi":["10.5772/55269"]},"title":[{"title_sort":"preliminary study of fast virtual stent-graft deployment","subtitle":"application to Stanford type B aortic dissection","title":"A preliminary study of fast virtual stent-graft deployment"}],"person":[{"family":"Chen","given":"Duanduan","display":"Chen, Duanduan","role":"aut"},{"role":"aut","given":"Matthias","display":"Müller-Eschner, Matthias","family":"Müller-Eschner"},{"display":"Rengier, Fabian","given":"Fabian","role":"aut","family":"Rengier"},{"given":"Drosos","display":"Kotelis, Drosos","role":"aut","family":"Kotelis"},{"family":"Böckler","display":"Böckler, Dittmar","given":"Dittmar","role":"aut"},{"role":"aut","given":"Yiannis","display":"Ventikos, Yiannis","family":"Ventikos"},{"family":"Xu","role":"aut","given":"Yong","display":"Xu, Yong"},{"given":"Yanjun","display":"Zeng, Yanjun","role":"aut","family":"Zeng"},{"role":"aut","given":"Yuhua","display":"Peng, Yuhua","family":"Peng"},{"display":"Tengg-Kobligk, Hendrik von","given":"Hendrik von","role":"aut","family":"Tengg-Kobligk"}],"language":["eng"],"name":{"displayForm":["Duanduan Chen, Matthias Müller-Eschner, Fabian Rengier, Drosos Kotelis, Dittmar Böckler, Yiannis Ventikos, Yong Xu, Yanjun Zeng, Yuhua Peng and Hendrik von Tengg-Kobligk"]},"type":{"bibl":"article-journal","media":"Online-Ressource"}} 
SRT |a CHENDUANDUPRELIMINAR1201