A patient-specific study of type-B aortic dissection: evaluation of true-false lumen blood exchange

Background - Aortic dissection is a severe pathological condition in which blood penetrates between layers of the aortic wall and creates a duplicate channel - the false lumen. This considerable change on the aortic morphology alters hemodynamic features dramatically and, in the case of rupture, ind...

Full description

Saved in:
Bibliographic Details
Main Authors: Chen, Duanduan (Author) , Müller-Eschner, Matthias (Author) , Tengg-Kobligk, Hendrik von (Author) , Barber, David (Author) , Böckler, Dittmar (Author) , Hose, Rod (Author) , Ventikos, Yiannis (Author)
Format: Article (Journal)
Language:English
Published: 2013 Jul 6
In: Biomedical engineering online
Year: 2013, Volume: 12, Pages: 1-16
ISSN:1475-925X
DOI:10.1186/1475-925X-12-65
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1186/1475-925X-12-65
Verlag, lizenzpflichtig, Volltext: https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3734007/
Get full text
Author Notes:Duanduan Chen, Matthias Müller-Eschner, Hendrik von Tengg-Kobligk, David Barber, Dittmar Böckler, Rod Hose and Yiannis Ventikos

MARC

LEADER 00000caa a2200000 c 4500
001 1753552680
003 DE-627
005 20220819160934.0
007 cr uuu---uuuuu
008 210409s2013 xx |||||o 00| ||eng c
024 7 |a 10.1186/1475-925X-12-65  |2 doi 
035 |a (DE-627)1753552680 
035 |a (DE-599)KXP1753552680 
035 |a (OCoLC)1341403805 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Chen, Duanduan  |e VerfasserIn  |0 (DE-588)1230833838  |0 (DE-627)1753200423  |4 aut 
245 1 2 |a A patient-specific study of type-B aortic dissection  |b evaluation of true-false lumen blood exchange  |c Duanduan Chen, Matthias Müller-Eschner, Hendrik von Tengg-Kobligk, David Barber, Dittmar Böckler, Rod Hose and Yiannis Ventikos 
264 1 |c 2013 Jul 6 
300 |a 16 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 09.04.2021 
520 |a Background - Aortic dissection is a severe pathological condition in which blood penetrates between layers of the aortic wall and creates a duplicate channel - the false lumen. This considerable change on the aortic morphology alters hemodynamic features dramatically and, in the case of rupture, induces markedly high rates of morbidity and mortality. - - Methods - In this study, we establish a patient-specific computational model and simulate the pulsatile blood flow within the dissected aorta. The k-ω SST turbulence model is employed to represent the flow and finite volume method is applied for numerical solutions. Our emphasis is on flow exchange between true and false lumen during the cardiac cycle and on quantifying the flow across specific passages. Loading distributions including pressure and wall shear stress have also been investigated and results of direct simulations are compared with solutions employing appropriate turbulence models. - - Results - Our results indicate that (i) high velocities occur at the periphery of the entries; (ii) for the case studied, approximately 40% of the blood flow passes the false lumen during a heartbeat cycle; (iii) higher pressures are found at the outer wall of the dissection, which may induce further dilation of the pseudo-lumen; (iv) highest wall shear stresses occur around the entries, perhaps indicating the vulnerability of this region to further splitting; and (v) laminar simulations with adequately fine mesh resolutions, especially refined near the walls, can capture similar flow patterns to the (coarser mesh) turbulent results, although the absolute magnitudes computed are in general smaller. - - Conclusions - The patient-specific model of aortic dissection provides detailed flow information of blood transport within the true and false lumen and quantifies the loading distributions over the aorta and dissection walls. This contributes to evaluating potential thrombotic behavior in the false lumen and is pivotal in guiding endovascular intervention. Moreover, as a computational study, mesh requirements to successfully evaluate the hemodynamic parameters have been proposed. 
700 1 |a Müller-Eschner, Matthias  |d 1981-  |e VerfasserIn  |0 (DE-588)138904022  |0 (DE-627)703146246  |0 (DE-576)30952122X  |4 aut 
700 1 |a Tengg-Kobligk, Hendrik von  |d 1972-  |e VerfasserIn  |0 (DE-588)129455733  |0 (DE-627)397663188  |0 (DE-576)297668501  |4 aut 
700 1 |a Barber, David  |d 1968-  |e VerfasserIn  |0 (DE-588)1014941148  |0 (DE-627)705306887  |0 (DE-576)349869154  |4 aut 
700 1 |a Böckler, Dittmar  |d 1966-  |e VerfasserIn  |0 (DE-588)1032367881  |0 (DE-627)738382868  |0 (DE-576)173503969  |4 aut 
700 1 |a Hose, Rod  |e VerfasserIn  |4 aut 
700 1 |a Ventikos, Yiannis  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Biomedical engineering online  |d London : BioMed Central, 2002  |g 12(2013), Artikel-ID 65, Seite 1-16  |h Online-Ressource  |w (DE-627)35210547X  |w (DE-600)2084374-4  |w (DE-576)107015161  |x 1475-925X  |7 nnas  |a A patient-specific study of type-B aortic dissection evaluation of true-false lumen blood exchange 
773 1 8 |g volume:12  |g year:2013  |g elocationid:65  |g pages:1-16  |g extent:16  |a A patient-specific study of type-B aortic dissection evaluation of true-false lumen blood exchange 
856 4 0 |u https://doi.org/10.1186/1475-925X-12-65  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3734007/  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20210409 
993 |a Article 
994 |a 2013 
998 |g 1032367881  |a Böckler, Dittmar  |m 1032367881:Böckler, Dittmar  |d 910000  |d 910200  |e 910000PB1032367881  |e 910200PB1032367881  |k 0/910000/  |k 1/910000/910200/  |p 5 
998 |g 129455733  |a Tengg-Kobligk, Hendrik von  |m 129455733:Tengg-Kobligk, Hendrik von  |d 50000  |e 50000PT129455733  |k 0/50000/  |p 3 
998 |g 138904022  |a Müller-Eschner, Matthias  |m 138904022:Müller-Eschner, Matthias  |p 2 
999 |a KXP-PPN1753552680  |e 3904241028 
BIB |a Y 
SER |a journal 
JSO |a {"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"name":{"displayForm":["Duanduan Chen, Matthias Müller-Eschner, Hendrik von Tengg-Kobligk, David Barber, Dittmar Böckler, Rod Hose and Yiannis Ventikos"]},"title":[{"subtitle":"evaluation of true-false lumen blood exchange","title_sort":"patient-specific study of type-B aortic dissection","title":"A patient-specific study of type-B aortic dissection"}],"person":[{"role":"aut","display":"Chen, Duanduan","given":"Duanduan","family":"Chen"},{"family":"Müller-Eschner","display":"Müller-Eschner, Matthias","given":"Matthias","role":"aut"},{"role":"aut","given":"Hendrik von","display":"Tengg-Kobligk, Hendrik von","family":"Tengg-Kobligk"},{"family":"Barber","given":"David","display":"Barber, David","role":"aut"},{"family":"Böckler","role":"aut","display":"Böckler, Dittmar","given":"Dittmar"},{"family":"Hose","role":"aut","display":"Hose, Rod","given":"Rod"},{"family":"Ventikos","role":"aut","display":"Ventikos, Yiannis","given":"Yiannis"}],"id":{"doi":["10.1186/1475-925X-12-65"],"eki":["1753552680"]},"physDesc":[{"extent":"16 S."}],"origin":[{"dateIssuedKey":"2013","dateIssuedDisp":"2013 Jul 6"}],"note":["Gesehen am 09.04.2021"],"recId":"1753552680","relHost":[{"type":{"media":"Online-Ressource","bibl":"periodical"},"disp":"A patient-specific study of type-B aortic dissection evaluation of true-false lumen blood exchangeBiomedical engineering online","physDesc":[{"extent":"Online-Ressource"}],"title":[{"title":"Biomedical engineering online","title_sort":"Biomedical engineering online"}],"part":{"pages":"1-16","year":"2013","text":"12(2013), Artikel-ID 65, Seite 1-16","extent":"16","volume":"12"},"language":["eng"],"id":{"issn":["1475-925X"],"zdb":["2084374-4"],"eki":["35210547X"]},"pubHistory":["1.2002 -"],"origin":[{"publisherPlace":"London","dateIssuedKey":"2002","dateIssuedDisp":"2002-","publisher":"BioMed Central"}],"note":["Gesehen am 20.05.2020"],"recId":"35210547X"}]} 
SRT |a CHENDUANDUPATIENTSPE2013