Analysis of cocaine, benzoylecgonine ecgonine methyl ester, and ecgonine by high-pressure liquid chromatography-API mass spectrometry and application to a short-term degradation study of cocaine in plasma

A method for the determination of cocaine (COC), benzoylecgonine (BE), ecgonine methyl ester (EME), and ecgonine (ECG) in plasma by liquid chromatography-mass spectrometry (LC-MS-MS) was developed. The analytes were isolated from human plasma by subsequent solid-phase extraction and were separated o...

Full description

Saved in:
Bibliographic Details
Main Authors: Klingmann, Andrea (Author) , Skopp, Gisela (Author) , Aderjan, Rolf (Author)
Format: Article (Journal)
Language:English
Published: 01 September 2001
In: Journal of analytical toxicology
Year: 2001, Volume: 25, Issue: 6, Pages: 425-430
ISSN:1945-2403
DOI:10.1093/jat/25.6.425
Online Access:Resolving-System, lizenzpflichtig, Volltext: https://doi.org/10.1093/jat/25.6.425
Verlag, lizenzpflichtig, Volltext: https://academic.oup.com/jat/article/25/6/425/706732
Get full text
Author Notes:Andrea Klingmann, Gisela Skopp, and Rolf Aderjan

MARC

LEADER 00000caa a2200000 c 4500
001 1756117721
003 DE-627
005 20220819184647.0
007 cr uuu---uuuuu
008 210428s2001 xx |||||o 00| ||eng c
024 7 |a 10.1093/jat/25.6.425  |2 doi 
035 |a (DE-627)1756117721 
035 |a (DE-599)KXP1756117721 
035 |a (OCoLC)1341406971 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Klingmann, Andrea  |d 1969-  |e VerfasserIn  |0 (DE-588)123512670  |0 (DE-627)706327551  |0 (DE-576)184961602  |4 aut 
245 1 0 |a Analysis of cocaine, benzoylecgonine ecgonine methyl ester, and ecgonine by high-pressure liquid chromatography-API mass spectrometry and application to a short-term degradation study of cocaine in plasma  |c Andrea Klingmann, Gisela Skopp, and Rolf Aderjan 
264 1 |c 01 September 2001 
300 |a 6 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 28.04.2021 
520 |a A method for the determination of cocaine (COC), benzoylecgonine (BE), ecgonine methyl ester (EME), and ecgonine (ECG) in plasma by liquid chromatography-mass spectrometry (LC-MS-MS) was developed. The analytes were isolated from human plasma by subsequent solid-phase extraction and were separated on a Zorbax Eclipse XDB-C8 narrow-bore column using an ammonium acetate buffer/acetonitrile/methanol gradient. A Turbolonspray® source was used for ionization. The analytes were characterized by their particular molecular ion and several fragments. Multiple reaction monitoring (MRM) was used for isolation and quantitation. The assay was rapid, highly sensitive, and reliable. The method was applied to monitor the in vitro degradation of cocaine in plasma. Fresh unpreserved and preserved (0.25 % KF) plasma samples were spiked with 1000 ng cocaine/mL. Aliquots of both series were stored at 4°C and 20°C and were analyzed at selected storage times of up to 15 days. In all samples, degradation of cocaine that was dependent on storage time and temperature and on sample preservation could be observed. The formation of BE did not occur to a significant extent (< 12%, referred to the initial concentration of COC), and its concentration was slightly higher in preserved compared with unpreserved plasma at both storage temperatures chosen. EME was formed in considerably higher amounts compared to BE. As already observed for COC, its formation and degradation were dependent on storage time, temperature, and preservation. EME is suggested to be the major source of ECG, which was detectable in all samples after 1-2 days of storage. Although the degradation of COC was shown to be highly dynamic in nature, the sum of all hydrolysis products of COC accounted for the initial COC concentration at any particular time of storage. Therefore, production of hitherto unknown degradation products of COC seems unlikely. Moreover, the common transformation product of BE and EME appeared to he stable, and ECG is suggested as a promising postcollection artifact. 
700 1 |a Skopp, Gisela  |d 1951-  |e VerfasserIn  |0 (DE-588)1060738538  |0 (DE-627)800969413  |0 (DE-576)164452346  |4 aut 
700 1 |a Aderjan, Rolf  |d 1944-  |e VerfasserIn  |0 (DE-588)11816631X  |0 (DE-627)694728748  |0 (DE-576)291748465  |4 aut 
773 0 8 |i Enthalten in  |t Journal of analytical toxicology  |d Oxford : Oxford Univ. Press, 1977  |g 25(2001), 6, Seite 425-430  |h Online-Ressource  |w (DE-627)32048954X  |w (DE-600)2010848-5  |w (DE-576)098000063  |x 1945-2403  |7 nnas  |a Analysis of cocaine, benzoylecgonine ecgonine methyl ester, and ecgonine by high-pressure liquid chromatography-API mass spectrometry and application to a short-term degradation study of cocaine in plasma 
773 1 8 |g volume:25  |g year:2001  |g number:6  |g pages:425-430  |g extent:6  |a Analysis of cocaine, benzoylecgonine ecgonine methyl ester, and ecgonine by high-pressure liquid chromatography-API mass spectrometry and application to a short-term degradation study of cocaine in plasma 
856 4 0 |u https://doi.org/10.1093/jat/25.6.425  |x Resolving-System  |x Verlag  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://academic.oup.com/jat/article/25/6/425/706732  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20210428 
993 |a Article 
994 |a 2001 
998 |g 11816631X  |a Aderjan, Rolf  |m 11816631X:Aderjan, Rolf  |d 910000  |d 912100  |e 910000PA11816631X  |e 912100PA11816631X  |k 0/910000/  |k 1/910000/912100/  |p 3  |y j 
998 |g 1060738538  |a Skopp, Gisela  |m 1060738538:Skopp, Gisela  |d 910000  |d 912100  |e 910000PS1060738538  |e 912100PS1060738538  |k 0/910000/  |k 1/910000/912100/  |p 2 
998 |g 123512670  |a Klingmann, Andrea  |m 123512670:Klingmann, Andrea  |d 50000  |e 50000PK123512670  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN1756117721  |e 3918620956 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"recId":"1756117721","note":["Gesehen am 28.04.2021"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"person":[{"family":"Klingmann","given":"Andrea","roleDisplay":"VerfasserIn","display":"Klingmann, Andrea","role":"aut"},{"family":"Skopp","given":"Gisela","display":"Skopp, Gisela","roleDisplay":"VerfasserIn","role":"aut"},{"roleDisplay":"VerfasserIn","display":"Aderjan, Rolf","role":"aut","family":"Aderjan","given":"Rolf"}],"title":[{"title":"Analysis of cocaine, benzoylecgonine ecgonine methyl ester, and ecgonine by high-pressure liquid chromatography-API mass spectrometry and application to a short-term degradation study of cocaine in plasma","title_sort":"Analysis of cocaine, benzoylecgonine ecgonine methyl ester, and ecgonine by high-pressure liquid chromatography-API mass spectrometry and application to a short-term degradation study of cocaine in plasma"}],"relHost":[{"origin":[{"publisherPlace":"Oxford ; Niles, Ill.","dateIssuedDisp":"1977-","publisher":"Oxford Univ. Press ; Preston Publ.","dateIssuedKey":"1977"}],"id":{"issn":["1945-2403"],"zdb":["2010848-5"],"eki":["32048954X"]},"physDesc":[{"extent":"Online-Ressource"}],"title":[{"title_sort":"Journal of analytical toxicology","title":"Journal of analytical toxicology","subtitle":"JAT ; the international source for practical clinical, forensic applications for isolating, identifying and quantitating potentially toxic substances"}],"note":["Gesehen am 18.02.14"],"disp":"Analysis of cocaine, benzoylecgonine ecgonine methyl ester, and ecgonine by high-pressure liquid chromatography-API mass spectrometry and application to a short-term degradation study of cocaine in plasmaJournal of analytical toxicology","type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng"],"recId":"32048954X","pubHistory":["1.1977 -"],"part":{"volume":"25","text":"25(2001), 6, Seite 425-430","extent":"6","year":"2001","pages":"425-430","issue":"6"},"titleAlt":[{"title":"JAT"}]}],"physDesc":[{"extent":"6 S."}],"name":{"displayForm":["Andrea Klingmann, Gisela Skopp, and Rolf Aderjan"]},"id":{"eki":["1756117721"],"doi":["10.1093/jat/25.6.425"]},"origin":[{"dateIssuedKey":"2001","dateIssuedDisp":"01 September 2001"}]} 
SRT |a KLINGMANNAANALYSISOF0120