Dosimetry auditing procedure with alanine dosimeters for light ion beam therapy

Background and purpose - In the next few years the number of facilities providing ion beam therapy with scanning beams will increase. An auditing process based on an end-to-end test (including CT imaging, planning and dose delivery) could help new ion therapy centres to validate their entire logisti...

Full description

Saved in:
Bibliographic Details
Main Authors: Ableitinger, Alexander (Author) , Vatnitsky, Stanislav (Author) , Herrmann, Rochus (Author) , Bassler, Niels (Author) , Palmans, Hugo (Author) , Sharpe, Peter (Author) , Ecker, Swantje (Author) , Chaudhri, Naved Sarwar (Author) , Jäkel, Oliver (Author) , Georg, Dietmar (Author)
Format: Article (Journal)
Language:English
Published: 22 July 2013
In: Radiotherapy and oncology
Year: 2013, Volume: 108, Issue: 1, Pages: 99-106
ISSN:1879-0887
DOI:10.1016/j.radonc.2013.04.029
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.radonc.2013.04.029
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0167814013002752
Get full text
Author Notes:Alexander Ableitinger, Stanislav Vatnitsky, Rochus Herrmann, Niels Bassler, Hugo Palmans, Peter Sharpe, Swantje Ecker, Naved Chaudhri, Oliver Jäkel, Dietmar Georg

MARC

LEADER 00000caa a2200000 c 4500
001 1757135006
003 DE-627
005 20220819194029.0
007 cr uuu---uuuuu
008 210505s2013 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.radonc.2013.04.029  |2 doi 
035 |a (DE-627)1757135006 
035 |a (DE-599)KXP1757135006 
035 |a (OCoLC)1341408198 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Ableitinger, Alexander  |e VerfasserIn  |0 (DE-588)1232831468  |0 (DE-627)1757135634  |4 aut 
245 1 0 |a Dosimetry auditing procedure with alanine dosimeters for light ion beam therapy  |c Alexander Ableitinger, Stanislav Vatnitsky, Rochus Herrmann, Niels Bassler, Hugo Palmans, Peter Sharpe, Swantje Ecker, Naved Chaudhri, Oliver Jäkel, Dietmar Georg 
264 1 |c 22 July 2013 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 05.05.2021 
520 |a Background and purpose - In the next few years the number of facilities providing ion beam therapy with scanning beams will increase. An auditing process based on an end-to-end test (including CT imaging, planning and dose delivery) could help new ion therapy centres to validate their entire logistic chain of radiation delivery. An end-to-end procedure was designed and tested in both scanned proton and carbon ion beams, which may also serve as a dosimetric credentialing procedure for clinical trials in the future. The developed procedure is focused only on physical dose delivery and the validation of the biological dose is out of scope of the current work. - Materials and methods - The audit procedure was based on a homogeneous phantom that mimics the dimension of a head (20×20×21cm3). The phantom can be loaded either with an ionisation chamber or 20 alanine dosimeters plus 2 radiochromic EBT films. Dose verification aimed at measuring a dose of 10Gy homogeneously delivered to a virtual-target volume of 8×8×12cm3. In order to interpret the readout of the irradiated alanine dosimeters additional Monte Carlo simulations were performed to calculate the energy dependent detector response of the particle fluence in the alanine detector. A pilot run was performed with protons and carbon ions at the Heidelberg Ion Therapy facility (HIT). - Results - The mean difference of the absolute physical dose measured with the alanine dosimeters compared with the expected dose from the treatment planning system was −2.4±0.9% (1σ) for protons and −2.2±1.1% (1σ) for carbon ions. The measurements performed with the ionisation chamber indicate this slight underdosage with a dose difference of −1.7% for protons and −1.0% for carbon ions. The profiles measured by radiochromic films showed an acceptable homogeneity of about 3%. - Conclusions - Alanine dosimeters are suitable detectors for dosimetry audits in ion beam therapy and the presented end-to-end test is feasible. If further studies show similar results, this dosimetric audit could be implemented as a credentialing procedure for clinical proton and carbon beam delivery. 
650 4 |a Alanine 
650 4 |a Audit 
650 4 |a Carbon ions 
650 4 |a Dosimetry 
650 4 |a Protons 
700 1 |a Vatnitsky, Stanislav  |e VerfasserIn  |4 aut 
700 1 |a Herrmann, Rochus  |e VerfasserIn  |4 aut 
700 1 |a Bassler, Niels  |e VerfasserIn  |4 aut 
700 1 |a Palmans, Hugo  |e VerfasserIn  |4 aut 
700 1 |a Sharpe, Peter  |e VerfasserIn  |4 aut 
700 1 |a Ecker, Swantje  |e VerfasserIn  |0 (DE-588)1075079373  |0 (DE-627)832927473  |0 (DE-576)443252998  |4 aut 
700 1 |a Chaudhri, Naved Sarwar  |d 1977-  |e VerfasserIn  |0 (DE-588)142075590  |0 (DE-627)704136422  |0 (DE-576)327472723  |4 aut 
700 1 |a Jäkel, Oliver  |d 1964-  |e VerfasserIn  |0 (DE-588)1050056302  |0 (DE-627)783260709  |0 (DE-576)404358705  |4 aut 
700 1 |a Georg, Dietmar  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Radiotherapy and oncology  |d Amsterdam [u.a.] : Elsevier Science, 1983  |g 108(2013), 1 vom: Juli, Seite 99-106  |h Online-Ressource  |w (DE-627)306710110  |w (DE-600)1500707-8  |w (DE-576)082435731  |x 1879-0887  |7 nnas  |a Dosimetry auditing procedure with alanine dosimeters for light ion beam therapy 
773 1 8 |g volume:108  |g year:2013  |g number:1  |g month:07  |g pages:99-106  |g extent:8  |a Dosimetry auditing procedure with alanine dosimeters for light ion beam therapy 
856 4 0 |u https://doi.org/10.1016/j.radonc.2013.04.029  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0167814013002752  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20210505 
993 |a Article 
994 |a 2013 
998 |g 1050056302  |a Jäkel, Oliver  |m 1050056302:Jäkel, Oliver  |d 50000  |e 50000PJ1050056302  |k 0/50000/  |p 9 
999 |a KXP-PPN1757135006  |e 3923341369 
BIB |a Y 
SER |a journal 
JSO |a {"physDesc":[{"extent":"8 S."}],"recId":"1757135006","note":["Gesehen am 05.05.2021"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"title":[{"title_sort":"Dosimetry auditing procedure with alanine dosimeters for light ion beam therapy","title":"Dosimetry auditing procedure with alanine dosimeters for light ion beam therapy"}],"person":[{"display":"Ableitinger, Alexander","family":"Ableitinger","given":"Alexander","role":"aut"},{"family":"Vatnitsky","given":"Stanislav","role":"aut","display":"Vatnitsky, Stanislav"},{"display":"Herrmann, Rochus","given":"Rochus","role":"aut","family":"Herrmann"},{"family":"Bassler","given":"Niels","role":"aut","display":"Bassler, Niels"},{"given":"Hugo","role":"aut","family":"Palmans","display":"Palmans, Hugo"},{"family":"Sharpe","given":"Peter","role":"aut","display":"Sharpe, Peter"},{"display":"Ecker, Swantje","given":"Swantje","role":"aut","family":"Ecker"},{"display":"Chaudhri, Naved Sarwar","family":"Chaudhri","role":"aut","given":"Naved Sarwar"},{"display":"Jäkel, Oliver","family":"Jäkel","role":"aut","given":"Oliver"},{"family":"Georg","given":"Dietmar","role":"aut","display":"Georg, Dietmar"}],"relHost":[{"origin":[{"dateIssuedKey":"1983","publisherPlace":"Amsterdam [u.a.]","dateIssuedDisp":"1983-","publisher":"Elsevier Science"}],"title":[{"subtitle":"journal of the European Society for Therapeutic Radiology and Oncology","title_sort":"Radiotherapy and oncology","title":"Radiotherapy and oncology"}],"note":["Gesehen am 30.05.15","Ungezählte Beil.: Supplement"],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"periodical"},"recId":"306710110","physDesc":[{"extent":"Online-Ressource"}],"disp":"Dosimetry auditing procedure with alanine dosimeters for light ion beam therapyRadiotherapy and oncology","pubHistory":["1.1983 -"],"titleAlt":[{"title":"The green journal"}],"part":{"year":"2013","volume":"108","pages":"99-106","extent":"8","text":"108(2013), 1 vom: Juli, Seite 99-106","issue":"1"},"id":{"eki":["306710110"],"issn":["1879-0887"],"zdb":["1500707-8"]}}],"origin":[{"dateIssuedDisp":"22 July 2013","dateIssuedKey":"2013"}],"id":{"doi":["10.1016/j.radonc.2013.04.029"],"eki":["1757135006"]},"name":{"displayForm":["Alexander Ableitinger, Stanislav Vatnitsky, Rochus Herrmann, Niels Bassler, Hugo Palmans, Peter Sharpe, Swantje Ecker, Naved Chaudhri, Oliver Jäkel, Dietmar Georg"]}} 
SRT |a ABLEITINGEDOSIMETRYA2220