Forces at the anterior meniscus attachments strongly increase under dynamic knee joint loading
Background:The anatomic appearance and biomechanical and clinical importance of the anterior meniscus roots are well described. However, little is known about the loads that act on these attachment structures under physiological joint loads and movements.Hypotheses:As compared with uniaxial loading...
Gespeichert in:
| Hauptverfasser: | , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
February 9, 2021
|
| In: |
The American journal of sports medicine
Year: 2021, Jahrgang: 49, Heft: 4, Pages: 994-1004 |
| ISSN: | 1552-3365 |
| DOI: | 10.1177/0363546520988039 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1177/0363546520988039 |
| Verfasserangaben: | Andreas Martin Seitz,*PhD, Florian Schall, PhD, Steffen Paul Hacker, PhD, Stefan van Drongelen, PhD, Sebastian Wolf, PhD, and Lutz Dürselen, PhD; Investigation performed at the Institute of Orthopaedic Research and Biomechanics, Ulm, Germany |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1757212442 | ||
| 003 | DE-627 | ||
| 005 | 20230426114308.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 210506s2021 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1177/0363546520988039 |2 doi | |
| 035 | |a (DE-627)1757212442 | ||
| 035 | |a (DE-599)KXP1757212442 | ||
| 035 | |a (OCoLC)1341408153 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Seitz, Andreas Martin |d 1980- |e VerfasserIn |0 (DE-588)1047700417 |0 (DE-627)778943755 |0 (DE-576)401524353 |4 aut | |
| 245 | 1 | 0 | |a Forces at the anterior meniscus attachments strongly increase under dynamic knee joint loading |c Andreas Martin Seitz,*PhD, Florian Schall, PhD, Steffen Paul Hacker, PhD, Stefan van Drongelen, PhD, Sebastian Wolf, PhD, and Lutz Dürselen, PhD; Investigation performed at the Institute of Orthopaedic Research and Biomechanics, Ulm, Germany |
| 264 | 1 | |c February 9, 2021 | |
| 300 | |a 11 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 06.05.2021 | ||
| 520 | |a Background:The anatomic appearance and biomechanical and clinical importance of the anterior meniscus roots are well described. However, little is known about the loads that act on these attachment structures under physiological joint loads and movements.Hypotheses:As compared with uniaxial loading conditions under static knee flexion angles or at very low flexion-extension speeds, more realistic continuous movement simulations in combination with physiological muscle force simulations lead to significantly higher anterior meniscus attachment forces. This increase is even more pronounced in combination with a longitudinal meniscal tear or after total medial meniscectomy.Study Design:Controlled laboratory study.Methods:A validated Oxford Rig?like knee simulator was used to perform a slow squat, a fast squat, and jump landing maneuvers on 9 cadaveric human knee joints, with and without muscle force simulation. The strains in the anterior medial and lateral meniscal periphery and the respective attachments were determined in 3 states: intact meniscus, medial longitudinal tear, and total medial meniscectomy. To determine the attachment forces, a subsequent in situ tensile test was performed.Results:Muscle force simulation resulted in a significant strain increase at the anterior meniscus attachments of up to 308% (P < .038) and the anterior meniscal periphery of up to 276%. This corresponded to significantly increased forces (P < .038) acting in the anteromedial attachment with a maximum force of 140 N, as determined during the jump landing simulation. Meniscus attachment strains and forces were significantly influenced (P = .008) by the longitudinal tear and meniscectomy during the drop jump simulation.Conclusion:Medial and lateral anterior meniscus attachment strains and forces were significantly increased with physiological muscle force simulation, corroborating our hypothesis. Therefore, in vitro tests applying uniaxial loads combined with static knee flexion angles or very low flexion-extension speeds appear to underestimate meniscus attachment forces.Clinical Relevance:The data of the present study might help to optimize the anchoring of meniscal allografts and artificial meniscal substitutes to the tibial plateau. Furthermore, this is the first in vitro study to indicate reasonable minimum stability requirements regarding the reattachment of torn anterior meniscus roots. | ||
| 650 | 4 | |a biomechanics articular cartilage | |
| 650 | 4 | |a biomechanics of ligament | |
| 650 | 4 | |a biomechanics, general | |
| 650 | 4 | |a knee ligaments, general | |
| 650 | 4 | |a knee simulator | |
| 650 | 4 | |a knee, articular cartilage | |
| 650 | 4 | |a knee, meniscus | |
| 650 | 4 | |a meniscus attachment | |
| 650 | 4 | |a tibiofemoral contact mechanics | |
| 700 | 1 | |a Schall, Florian |e VerfasserIn |4 aut | |
| 700 | 1 | |a Hacker, Steffen Paul |e VerfasserIn |4 aut | |
| 700 | 1 | |a Drongelen, Stefan van |e VerfasserIn |0 (DE-588)1082242896 |0 (DE-627)847238113 |0 (DE-576)455270740 |4 aut | |
| 700 | 1 | |a Wolf, Sebastian Immanuel |d 1965- |e VerfasserIn |0 (DE-588)1051004578 |0 (DE-627)785483861 |0 (DE-576)40544849X |4 aut | |
| 700 | 1 | |a Dürselen, Lutz |e VerfasserIn |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t The American journal of sports medicine |d London [u.a.] : Sage, 1976 |g 49(2021), 4, Seite 994-1004 |h Online-Ressource |w (DE-627)337900019 |w (DE-600)2063945-4 |w (DE-576)097935077 |x 1552-3365 |7 nnas |a Forces at the anterior meniscus attachments strongly increase under dynamic knee joint loading |
| 773 | 1 | 8 | |g volume:49 |g year:2021 |g number:4 |g pages:994-1004 |g extent:11 |a Forces at the anterior meniscus attachments strongly increase under dynamic knee joint loading |
| 856 | 4 | 0 | |u https://doi.org/10.1177/0363546520988039 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20210506 | ||
| 993 | |a Article | ||
| 994 | |a 2021 | ||
| 998 | |g 1051004578 |a Wolf, Sebastian Immanuel |m 1051004578:Wolf, Sebastian Immanuel |d 910000 |d 911460 |e 910000PW1051004578 |e 911460PW1051004578 |k 0/910000/ |k 1/910000/911460/ |p 5 | ||
| 998 | |g 1082242896 |a Drongelen, Stefan van |m 1082242896:Drongelen, Stefan van |p 4 | ||
| 999 | |a KXP-PPN1757212442 |e 3924058598 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"note":["Gesehen am 06.05.2021"],"name":{"displayForm":["Andreas Martin Seitz,*PhD, Florian Schall, PhD, Steffen Paul Hacker, PhD, Stefan van Drongelen, PhD, Sebastian Wolf, PhD, and Lutz Dürselen, PhD; Investigation performed at the Institute of Orthopaedic Research and Biomechanics, Ulm, Germany"]},"recId":"1757212442","origin":[{"dateIssuedDisp":"February 9, 2021","dateIssuedKey":"2021"}],"language":["eng"],"person":[{"role":"aut","display":"Seitz, Andreas Martin","given":"Andreas Martin","family":"Seitz"},{"display":"Schall, Florian","role":"aut","family":"Schall","given":"Florian"},{"given":"Steffen Paul","family":"Hacker","role":"aut","display":"Hacker, Steffen Paul"},{"given":"Stefan van","family":"Drongelen","role":"aut","display":"Drongelen, Stefan van"},{"given":"Sebastian Immanuel","family":"Wolf","role":"aut","display":"Wolf, Sebastian Immanuel"},{"display":"Dürselen, Lutz","role":"aut","family":"Dürselen","given":"Lutz"}],"title":[{"title_sort":"Forces at the anterior meniscus attachments strongly increase under dynamic knee joint loading","title":"Forces at the anterior meniscus attachments strongly increase under dynamic knee joint loading"}],"relHost":[{"language":["eng"],"title":[{"title":"The American journal of sports medicine","title_sort":"American journal of sports medicine"}],"physDesc":[{"extent":"Online-Ressource"}],"note":["Gesehen am 24. Mai 2016"],"disp":"Forces at the anterior meniscus attachments strongly increase under dynamic knee joint loadingThe American journal of sports medicine","name":{"displayForm":["The American Orthopaedic Society for Sports Medicine"]},"corporate":[{"role":"isb","display":"American Orthopaedic Society for Sports Medicine"}],"pubHistory":["Volume 4 Issue 1 (January 1976) -"],"part":{"volume":"49","year":"2021","extent":"11","issue":"4","pages":"994-1004","text":"49(2021), 4, Seite 994-1004"},"type":{"bibl":"periodical","media":"Online-Ressource"},"id":{"zdb":["2063945-4"],"issn":["1552-3365"],"eki":["337900019"]},"recId":"337900019","origin":[{"dateIssuedDisp":"1976-","publisher":"Sage","publisherPlace":"London [u.a.]","dateIssuedKey":"1976"}]}],"physDesc":[{"extent":"11 S."}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"id":{"eki":["1757212442"],"doi":["10.1177/0363546520988039"]}} | ||
| SRT | |a SEITZANDREFORCESATTH9202 | ||