Analysis of inter- and intrafraction accuracy of a commercial thermoplastic mask system used for image-guided particle radiation therapy

The present paper reports and discusses the results concerning both the inter- and intrafraction accuracy achievable combining the immobilization system employed in patients with head-and-neck, brain and skull base tumors with image guidance at our particle therapy center. Moreover, we investigated...

Full description

Saved in:
Bibliographic Details
Main Authors: Amelio, Dante (Author) , Winter, Marcus (Author) , Habermehl, Daniel (Author) , Jäkel, Oliver (Author) , Debus, Jürgen (Author) , Combs, Stephanie (Author)
Format: Article (Journal)
Language:English
Published: 1 July 2013
In: Journal of radiation research
Year: 2013, Volume: 54, Pages: i69-i76
ISSN:1349-9157
DOI:10.1093/jrr/rrt038
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1093/jrr/rrt038
Get full text
Author Notes:Dante Amelio, Marcus Winter, Daniel Habermehl, Oliver Jäkel, Jurgen Debus and Stephanie E. Combs

MARC

LEADER 00000caa a2200000 c 4500
001 1757908552
003 DE-627
005 20220819205409.0
007 cr uuu---uuuuu
008 210517s2013 xx |||||o 00| ||eng c
024 7 |a 10.1093/jrr/rrt038  |2 doi 
035 |a (DE-627)1757908552 
035 |a (DE-599)KXP1757908552 
035 |a (OCoLC)1341409098 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Amelio, Dante  |e VerfasserIn  |0 (DE-588)1233608363  |0 (DE-627)1757909443  |4 aut 
245 1 0 |a Analysis of inter- and intrafraction accuracy of a commercial thermoplastic mask system used for image-guided particle radiation therapy  |c Dante Amelio, Marcus Winter, Daniel Habermehl, Oliver Jäkel, Jurgen Debus and Stephanie E. Combs 
264 1 |c 1 July 2013 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 17.05.2021 
520 |a The present paper reports and discusses the results concerning both the inter- and intrafraction accuracy achievable combining the immobilization system employed in patients with head-and-neck, brain and skull base tumors with image guidance at our particle therapy center. Moreover, we investigated the influence of intrafraction time on positioning displacements. A total of 41 patients treated between January and July 2011 represented the study population. All the patients were immobilized with a tailored commercial thermoplastic head mask with standard head-neck rest (HeadSTEP®, IT-V). Patient treatment position was verified by two orthogonal kilovoltage images acquired through a ceiling imaging robot (Siemens, Erlangen, Germany). The analysis of the applied daily corrections during the first treatment week before and after treatment delivery allowed the evaluation of the interfraction and intrafraction reproducibility of the thermoplastic mask, respectively. Concerning interfraction reproducibility, translational and rotational systematic errors (Σs) were ≤2.2 mm and 0.9º, respectively; translational and rotational random errors (σs) were ≤1.6 mm and 0.6º, respectively. Regarding the intrafraction accuracy translational and rotational Σs were ≤0.4 mm and 0.4º, respectively; translational and rotational σs were ≤ 0.5 mm and 0.3º, respectively. Concerning the time-intrafraction displacements correlation Pearson coefficient was 0.5 for treatment fractions with time between position checks less than or equal to median value, and 0.2 for those with time between position controls longer than the median figure. These results suggest that intrafractional patient motion is smaller than interfractional patient motion. Moreover, we can state that application of different imaging verification protocols translate into a relevant difference of accuracy for the same immobilization device. The magnitude of intrafraction displacements correlates with the time for short treatment sessions or during the early phase of long treatment delivery. 
700 1 |a Winter, Marcus  |e VerfasserIn  |0 (DE-588)116515871X  |0 (DE-627)1029325561  |0 (DE-576)510276121  |4 aut 
700 1 |a Habermehl, Daniel  |d 1979-  |e VerfasserIn  |0 (DE-588)13804130X  |0 (DE-627)598882472  |0 (DE-576)305815415  |4 aut 
700 1 |a Jäkel, Oliver  |d 1964-  |e VerfasserIn  |0 (DE-588)1050056302  |0 (DE-627)783260709  |0 (DE-576)404358705  |4 aut 
700 1 |a Debus, Jürgen  |d 1964-  |e VerfasserIn  |0 (DE-588)1022671421  |0 (DE-627)717025780  |0 (DE-576)365774944  |4 aut 
700 1 |a Combs, Stephanie  |d 1976-  |e VerfasserIn  |0 (DE-588)124782515  |0 (DE-627)366051245  |0 (DE-576)294499741  |4 aut 
773 0 8 |i Enthalten in  |t Journal of radiation research  |d [Oxford] : Oxford University Press, 1960  |g 54(2013), suppl 1, Seite i69-i76  |h Online-Ressource  |w (DE-627)32569608X  |w (DE-600)2038914-0  |w (DE-576)337261148  |x 1349-9157  |7 nnas  |a Analysis of inter- and intrafraction accuracy of a commercial thermoplastic mask system used for image-guided particle radiation therapy 
773 1 8 |g volume:54  |g year:2013  |g supplement:suppl 1  |g pages:i69-i76  |g extent:8  |a Analysis of inter- and intrafraction accuracy of a commercial thermoplastic mask system used for image-guided particle radiation therapy 
856 4 0 |u https://doi.org/10.1093/jrr/rrt038  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20210517 
993 |a Article 
994 |a 2013 
998 |g 124782515  |a Combs, Stephanie  |m 124782515:Combs, Stephanie  |d 910000  |d 911400  |e 910000PC124782515  |e 911400PC124782515  |k 0/910000/  |k 1/910000/911400/  |p 6  |y j 
998 |g 1022671421  |a Debus, Jürgen  |m 1022671421:Debus, Jürgen  |d 910000  |d 911400  |e 910000PD1022671421  |e 911400PD1022671421  |k 0/910000/  |k 1/910000/911400/  |p 5 
998 |g 1050056302  |a Jäkel, Oliver  |m 1050056302:Jäkel, Oliver  |d 50000  |e 50000PJ1050056302  |k 0/50000/  |p 4 
999 |a KXP-PPN1757908552  |e 3928998145 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"title":[{"title":"Journal of radiation research","title_sort":"Journal of radiation research"}],"id":{"issn":["1349-9157"],"eki":["32569608X"],"zdb":["2038914-0"]},"disp":"Analysis of inter- and intrafraction accuracy of a commercial thermoplastic mask system used for image-guided particle radiation therapyJournal of radiation research","origin":[{"publisherPlace":"[Oxford] ; Kawaguchi","dateIssuedKey":"1960","dateIssuedDisp":"1960-","publisher":"Oxford University Press ; J-STAGE"}],"corporate":[{"display":"Nihon Hōshasen Eikyō Gakkai","role":"isb"}],"note":["Gesehen am 22.06.20"],"pubHistory":["1.1960 -"],"part":{"extent":"8","volume":"54","text":"54(2013), suppl 1, Seite i69-i76","year":"2013","pages":"i69-i76"},"physDesc":[{"extent":"Online-Ressource"}],"recId":"32569608X","type":{"bibl":"periodical","media":"Online-Ressource"},"name":{"displayForm":["Japan Radiation Research Society"]},"language":["eng"]}],"physDesc":[{"extent":"8 S."}],"title":[{"title":"Analysis of inter- and intrafraction accuracy of a commercial thermoplastic mask system used for image-guided particle radiation therapy","title_sort":"Analysis of inter- and intrafraction accuracy of a commercial thermoplastic mask system used for image-guided particle radiation therapy"}],"note":["Gesehen am 17.05.2021"],"language":["eng"],"person":[{"role":"aut","family":"Amelio","display":"Amelio, Dante","given":"Dante"},{"given":"Marcus","role":"aut","family":"Winter","display":"Winter, Marcus"},{"family":"Habermehl","role":"aut","display":"Habermehl, Daniel","given":"Daniel"},{"given":"Oliver","family":"Jäkel","role":"aut","display":"Jäkel, Oliver"},{"given":"Jürgen","role":"aut","family":"Debus","display":"Debus, Jürgen"},{"display":"Combs, Stephanie","role":"aut","family":"Combs","given":"Stephanie"}],"id":{"doi":["10.1093/jrr/rrt038"],"eki":["1757908552"]},"recId":"1757908552","type":{"bibl":"article-journal","media":"Online-Ressource"},"origin":[{"dateIssuedDisp":"1 July 2013","dateIssuedKey":"2013"}],"name":{"displayForm":["Dante Amelio, Marcus Winter, Daniel Habermehl, Oliver Jäkel, Jurgen Debus and Stephanie E. Combs"]}} 
SRT |a AMELIODANTANALYSISOF1201