An experimental study to evaluate the Fluobeam 800 imaging system for fluorescence-guided lymphatic Imaging and sentinel node biopsy

Background. Visualization of the lymphatic system is challenging. Lymphatic imaging is a crucial diagnostic tool for benign and malignant lymphatic pathologies. Fluorescence-guided imaging allows selective lymphatic mapping and sentinel lymph node (SLN) identification. There are a few fluorescence s...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Hirche, Christoph (VerfasserIn) , Engel, Holger (VerfasserIn) , Harhaus-Wähner, Leila (VerfasserIn) , Cognie, Juliette (VerfasserIn) , Hünerbein, Michael (VerfasserIn) , Lehnhardt, Marcus (VerfasserIn) , Kremer, Thomas (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2013
In: Surgical innovation
Year: 2012, Jahrgang: 20, Heft: 5, Pages: 516-523
ISSN:1553-3514
DOI:10.1177/1553350612468962
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1177/1553350612468962
Volltext
Verfasserangaben:Christoph Hirche, Holger Engel, Leila Kolios, Juliette Cognie, Michael Hünerbein, Marcus Lehnhardt, and Thomas Kremer

MARC

LEADER 00000caa a2200000 c 4500
001 1759235512
003 DE-627
005 20220819220542.0
007 cr uuu---uuuuu
008 210531r20132012xx |||||o 00| ||eng c
024 7 |a 10.1177/1553350612468962  |2 doi 
035 |a (DE-627)1759235512 
035 |a (DE-599)KXP1759235512 
035 |a (OCoLC)1341414685 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Hirche, Christoph  |e VerfasserIn  |0 (DE-588)1074918878  |0 (DE-627)832738484  |0 (DE-576)414117387  |4 aut 
245 1 3 |a An experimental study to evaluate the Fluobeam 800 imaging system for fluorescence-guided lymphatic Imaging and sentinel node biopsy  |c Christoph Hirche, Holger Engel, Leila Kolios, Juliette Cognie, Michael Hünerbein, Marcus Lehnhardt, and Thomas Kremer 
264 1 |c 2013 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 31.05.2021 
500 |a  First Published December 27, 2012 
520 |a Background. Visualization of the lymphatic system is challenging. Lymphatic imaging is a crucial diagnostic tool for benign and malignant lymphatic pathologies. Fluorescence-guided imaging allows selective lymphatic mapping and sentinel lymph node (SLN) identification. There are a few fluorescence systems, but some drawbacks remain due to technical and ergonomic aspects. The aim of this study was to evaluate the feasibility of the new Fluobeam 800 imaging system. Methods. After approval by the ethics committee, the system was evaluated for lymphography and SLN biopsy in an animal model. Five pigs each with 4 lymph node (LN) stations (n = 20 LN stations) were subjected to lymphatic imaging using indocyanine green (ICG). Additionally, the use of ICG was compared with ICG adsorbed to human serum albumin (ICG-HSA). Lymphatic vessels and SLN identification rates were measured. Results. After injection, a clear fluorescence signal of the lymphatic vessels was visualized leading to the LN station. Overall, ICG fluorescence imaging identified a mean of 2.0 lymphatic vessels and 1.1 (range = 1-2) SLN in 20 of 20 LN stations. Reverse lymphography was feasible. A clinical difference in resolution was not detected between use of ICG-HSA and ICG. Conclusion. This is the first study analyzing the feasibility of the Fluobeam 800 imaging system allowing transcutaneous real-time imaging. It enables detection of the SLN by fluorescence retention with increased detection depth and resolution. After fixation to the ceiling, the ergonomics advanced for simultaneous field navigation and dissection. The new system can be applied for lymphatic imaging for lympatico-reconstructive surgery and SLN biopsy. 
534 |c 2012 
650 4 |a fluorescence 
650 4 |a ICG 
650 4 |a indocyanine green 
650 4 |a lymph node 
650 4 |a lymphatic imaging 
650 4 |a lymphedema 
650 4 |a sentinel lymph node biopsy 
650 4 |a solid tumors 
700 1 |a Engel, Holger  |d 1976-  |e VerfasserIn  |0 (DE-588)132925214  |0 (DE-627)528681265  |0 (DE-576)265625378  |4 aut 
700 1 |a Harhaus-Wähner, Leila  |d 1980-  |e VerfasserIn  |0 (DE-588)132529874  |0 (DE-627)523625944  |0 (DE-576)299205185  |4 aut 
700 1 |a Cognie, Juliette  |e VerfasserIn  |4 aut 
700 1 |a Hünerbein, Michael  |e VerfasserIn  |4 aut 
700 1 |a Lehnhardt, Marcus  |d 1968-  |e VerfasserIn  |0 (DE-588)122395794  |0 (DE-627)08191928X  |0 (DE-576)293252351  |4 aut 
700 1 |a Kremer, Thomas  |d 1975-  |e VerfasserIn  |0 (DE-588)128711310  |0 (DE-627)37830853X  |0 (DE-576)297293133  |4 aut 
773 0 8 |i Enthalten in  |t Surgical innovation  |d Thousand Oaks, Calif. : Sage, 2004  |g 20(2013), 5, Seite 516-523  |h Online-Ressource  |w (DE-627)511638272  |w (DE-600)2233576-6  |w (DE-576)276818199  |x 1553-3514  |7 nnas  |a An experimental study to evaluate the Fluobeam 800 imaging system for fluorescence-guided lymphatic Imaging and sentinel node biopsy 
773 1 8 |g volume:20  |g year:2013  |g number:5  |g pages:516-523  |g extent:8  |a An experimental study to evaluate the Fluobeam 800 imaging system for fluorescence-guided lymphatic Imaging and sentinel node biopsy 
856 4 0 |u https://doi.org/10.1177/1553350612468962  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20210531 
993 |a Article 
994 |a 2013 
998 |g 128711310  |a Kremer, Thomas  |m 128711310:Kremer, Thomas  |d 50000  |e 50000PK128711310  |k 0/50000/  |p 7  |y j 
998 |g 122395794  |a Lehnhardt, Marcus  |m 122395794:Lehnhardt, Marcus  |d 910000  |d 910200  |e 910000PL122395794  |e 910200PL122395794  |k 0/910000/  |k 1/910000/910200/  |p 6 
998 |g 132529874  |a Harhaus-Wähner, Leila  |m 132529874:Harhaus-Wähner, Leila  |d 50000  |e 50000PH132529874  |k 0/50000/  |p 3 
998 |g 132925214  |a Engel, Holger  |m 132925214:Engel, Holger  |p 2 
998 |g 1074918878  |a Hirche, Christoph  |m 1074918878:Hirche, Christoph  |d 50000  |e 50000PH1074918878  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN1759235512  |e 3932633989 
BIB |a Y 
SER |a journal 
JSO |a {"name":{"displayForm":["Christoph Hirche, Holger Engel, Leila Kolios, Juliette Cognie, Michael Hünerbein, Marcus Lehnhardt, and Thomas Kremer"]},"recId":"1759235512","id":{"doi":["10.1177/1553350612468962"],"eki":["1759235512"]},"origin":[{"dateIssuedKey":"2013","dateIssuedDisp":"2013"}],"language":["eng"],"physDesc":[{"extent":"8 S."}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"person":[{"role":"aut","given":"Christoph","family":"Hirche","display":"Hirche, Christoph"},{"display":"Engel, Holger","family":"Engel","role":"aut","given":"Holger"},{"family":"Harhaus-Wähner","role":"aut","given":"Leila","display":"Harhaus-Wähner, Leila"},{"role":"aut","given":"Juliette","family":"Cognie","display":"Cognie, Juliette"},{"display":"Hünerbein, Michael","family":"Hünerbein","given":"Michael","role":"aut"},{"family":"Lehnhardt","given":"Marcus","role":"aut","display":"Lehnhardt, Marcus"},{"family":"Kremer","role":"aut","given":"Thomas","display":"Kremer, Thomas"}],"title":[{"title":"An experimental study to evaluate the Fluobeam 800 imaging system for fluorescence-guided lymphatic Imaging and sentinel node biopsy","title_sort":"experimental study to evaluate the Fluobeam 800 imaging system for fluorescence-guided lymphatic Imaging and sentinel node biopsy"}],"relHost":[{"recId":"511638272","disp":"An experimental study to evaluate the Fluobeam 800 imaging system for fluorescence-guided lymphatic Imaging and sentinel node biopsySurgical innovation","id":{"issn":["1553-3514"],"zdb":["2233576-6"],"eki":["511638272"]},"origin":[{"publisherPlace":"Thousand Oaks, Calif.","dateIssuedDisp":"2004-","publisher":"Sage","dateIssuedKey":"2004"}],"part":{"year":"2013","issue":"5","volume":"20","pages":"516-523","extent":"8","text":"20(2013), 5, Seite 516-523"},"type":{"media":"Online-Ressource","bibl":"periodical"},"titleAlt":[{"title":"SRI"}],"note":["Gesehen am 14.10.2009"],"pubHistory":["11.2004,4 -"],"physDesc":[{"extent":"Online-Ressource"}],"language":["eng"],"title":[{"title":"Surgical innovation","title_sort":"Surgical innovation"}]}],"note":["Gesehen am 31.05.2021"," First Published December 27, 2012"]} 
SRT |a HIRCHECHRIEXPERIMENT2013