Technical considerations in MR angiography: an image-based guide
As the complexity of the magnetic resonance angiography (MRA) techniques grows, it becomes more difficult for the practicing radiologist to appreciate the physical principles underlying these studies. Nevertheless, such an understanding is requisite for improving clinical image quality. As radiologi...
Saved in:
| Main Authors: | , , , , , , |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
24 May 2013
|
| In: |
Journal of magnetic resonance imaging
Year: 2013, Volume: 37, Issue: 6, Pages: 1326-1341 |
| ISSN: | 1522-2586 |
| DOI: | https://doi.org/10.1002/jmri.24174 |
| Online Access: | Verlag, lizenzpflichtig, Volltext: https://doi.org/https://doi.org/10.1002/jmri.24174 Verlag, lizenzpflichtig, Volltext: https://www.onlinelibrary.wiley.com/doi/abs/10.1002/jmri.24174 |
| Author Notes: | John N. Morelli, MD, Clint M. Gerdes, MD, Peter Schmitt, PhD, Tao Ai, MD, Megan R. Saettele, MD, Val M. Runge, MD, and Ulrike I. Attenberger, MD |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1759918865 | ||
| 003 | DE-627 | ||
| 005 | 20220819222857.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 210607s2013 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1002/jmri.24174 |2 doi | |
| 035 | |a (DE-627)1759918865 | ||
| 035 | |a (DE-599)KXP1759918865 | ||
| 035 | |a (OCoLC)1341415377 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Morelli, John N. |e VerfasserIn |0 (DE-588)143389491 |0 (DE-627)704472864 |0 (DE-576)337212228 |4 aut | |
| 245 | 1 | 0 | |a Technical considerations in MR angiography |b an image-based guide |c John N. Morelli, MD, Clint M. Gerdes, MD, Peter Schmitt, PhD, Tao Ai, MD, Megan R. Saettele, MD, Val M. Runge, MD, and Ulrike I. Attenberger, MD |
| 264 | 1 | |c 24 May 2013 | |
| 300 | |a 16 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 07.06.2021 | ||
| 520 | |a As the complexity of the magnetic resonance angiography (MRA) techniques grows, it becomes more difficult for the practicing radiologist to appreciate the physical principles underlying these studies. Nevertheless, such an understanding is requisite for improving clinical image quality. As radiologists are most accustomed to dealing with medical images in everyday practice, it seems natural that an image-based approach to teaching MRA physics, rather than complex mathematical equations or pulse sequence diagrams, would be preferable. This article adopts such an approach. Simple ways to improve MRA image quality are emphasized along with new technologies and their physical basis. The ultimate goal of the article is to facilitate the practicing radiologist becoming more aware of the variety of MR techniques available, being more confident in modifying sequence parameters to improve image quality and reduce contrast dose, and understanding the basis behind newer MRA techniques. J. Magn. Reson. Imaging 2013;37:1326-1341. © 2013 Wiley Periodicals, Inc. | ||
| 650 | 4 | |a 3 T | |
| 650 | 4 | |a gadolinium chelates | |
| 650 | 4 | |a magnetic resonance angiography | |
| 650 | 4 | |a magnetic resonance venography | |
| 650 | 4 | |a parallel imaging | |
| 700 | 1 | |a Gerdes, Clint M. |e VerfasserIn |4 aut | |
| 700 | 1 | |a Schmitt, Peter |e VerfasserIn |4 aut | |
| 700 | 1 | |a Ai, Tao |e VerfasserIn |4 aut | |
| 700 | 1 | |a Saettele, Megan R. |e VerfasserIn |4 aut | |
| 700 | 1 | |a Runge, Val M. |e VerfasserIn |4 aut | |
| 700 | 1 | |a Attenberger, Ulrike |d 1980- |e VerfasserIn |0 (DE-588)131554859 |0 (DE-627)510698557 |0 (DE-576)298582775 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Journal of magnetic resonance imaging |d New York, NY : Wiley-Liss, 1991 |g 37(2013), 6, Seite 1326-1341 |h Online-Ressource |w (DE-627)306360039 |w (DE-600)1497154-9 |w (DE-576)114617252 |x 1522-2586 |7 nnas |a Technical considerations in MR angiography an image-based guide |
| 773 | 1 | 8 | |g volume:37 |g year:2013 |g number:6 |g pages:1326-1341 |g extent:16 |a Technical considerations in MR angiography an image-based guide |
| 856 | 4 | 0 | |u https://doi.org/https://doi.org/10.1002/jmri.24174 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://www.onlinelibrary.wiley.com/doi/abs/10.1002/jmri.24174 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20210607 | ||
| 993 | |a Article | ||
| 994 | |a 2013 | ||
| 998 | |g 131554859 |a Attenberger, Ulrike |m 131554859:Attenberger, Ulrike |d 60000 |d 62900 |e 60000PA131554859 |e 62900PA131554859 |k 0/60000/ |k 1/60000/62900/ |p 7 |y j | ||
| 999 | |a KXP-PPN1759918865 |e 3935131267 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"origin":[{"dateIssuedKey":"2013","dateIssuedDisp":"24 May 2013"}],"language":["eng"],"title":[{"title":"Technical considerations in MR angiography","title_sort":"Technical considerations in MR angiography","subtitle":"an image-based guide"}],"id":{"doi":["10.1002/jmri.24174"],"eki":["1759918865"]},"person":[{"role":"aut","display":"Morelli, John N.","roleDisplay":"VerfasserIn","family":"Morelli","given":"John N."},{"roleDisplay":"VerfasserIn","family":"Gerdes","given":"Clint M.","display":"Gerdes, Clint M.","role":"aut"},{"role":"aut","display":"Schmitt, Peter","given":"Peter","roleDisplay":"VerfasserIn","family":"Schmitt"},{"roleDisplay":"VerfasserIn","family":"Ai","given":"Tao","display":"Ai, Tao","role":"aut"},{"display":"Saettele, Megan R.","role":"aut","family":"Saettele","roleDisplay":"VerfasserIn","given":"Megan R."},{"family":"Runge","roleDisplay":"VerfasserIn","given":"Val M.","display":"Runge, Val M.","role":"aut"},{"display":"Attenberger, Ulrike","role":"aut","roleDisplay":"VerfasserIn","family":"Attenberger","given":"Ulrike"}],"physDesc":[{"extent":"16 S."}],"name":{"displayForm":["John N. Morelli, MD, Clint M. Gerdes, MD, Peter Schmitt, PhD, Tao Ai, MD, Megan R. Saettele, MD, Val M. Runge, MD, and Ulrike I. Attenberger, MD"]},"type":{"bibl":"article-journal","media":"Online-Ressource"},"relHost":[{"type":{"bibl":"periodical","media":"Online-Ressource"},"pubHistory":["1.1991 -"],"physDesc":[{"extent":"Online-Ressource"}],"title":[{"title":"Journal of magnetic resonance imaging","title_sort":"Journal of magnetic resonance imaging","subtitle":"JMRI ; an official journal of the International Society for Magnetic Resonance in Medicine"}],"part":{"extent":"16","volume":"37","year":"2013","pages":"1326-1341","issue":"6","text":"37(2013), 6, Seite 1326-1341"},"titleAlt":[{"title":"JMRI"}],"origin":[{"publisher":"Wiley-Liss","dateIssuedKey":"1991","dateIssuedDisp":"1991-","publisherPlace":"New York, NY"}],"note":["Gesehen am 28.02.08","Fortsetzung der CD-ROM-Ausgabe"],"recId":"306360039","id":{"zdb":["1497154-9"],"issn":["1522-2586"],"doi":["10.1002/(ISSN)1522-2586"],"eki":["306360039"]},"disp":"Technical considerations in MR angiography an image-based guideJournal of magnetic resonance imaging","language":["eng"]}],"recId":"1759918865","note":["Gesehen am 07.06.2021"]} | ||
| SRT | |a MORELLIJOHTECHNICALC2420 | ||