Line-FRAP, a versatile method to measure diffusion rates in vitro and in vivo

The crowded cellular milieu affect molecular diffusion through hard (occluded space) and soft (weak, non-specific) interactions. Multiple methods have been developed to measure diffusion coefficients at physiological protein concentrations within cells, each with its limitations. Here, we show that...

Full description

Saved in:
Bibliographic Details
Main Authors: Dey, Debabrata (Author) , Marciano, Shir (Author) , Nunes-Alves, Ariane (Author) , Kiss, Vladimir (Author) , Wade, Rebecca C. (Author) , Schreiber, Gideon (Author)
Format: Article (Journal)
Language:English
Published: 27 February 2021
In: Journal of molecular biology
Year: 2021, Volume: 433, Issue: 9, Pages: 1-20
ISSN:1089-8638
DOI:10.1016/j.jmb.2021.166898
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.jmb.2021.166898
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0022283621000929
Get full text
Author Notes:Debabrata Dey, Shir Marciano, Ariane Nunes-Alves, Vladimir Kiss, Rebecca C. Wade and Gideon Schreiber

MARC

LEADER 00000caa a2200000 c 4500
001 1760107808
003 DE-627
005 20240413193530.0
007 cr uuu---uuuuu
008 210609s2021 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.jmb.2021.166898  |2 doi 
035 |a (DE-627)1760107808 
035 |a (DE-599)KXP1760107808 
035 |a (OCoLC)1341415426 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 32  |2 sdnb 
100 1 |a Dey, Debabrata  |e VerfasserIn  |0 (DE-588)1235078604  |0 (DE-627)176010910X  |4 aut 
245 1 0 |a Line-FRAP, a versatile method to measure diffusion rates in vitro and in vivo  |c Debabrata Dey, Shir Marciano, Ariane Nunes-Alves, Vladimir Kiss, Rebecca C. Wade and Gideon Schreiber 
264 1 |c 27 February 2021 
300 |a 20 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 09.06.2021 
520 |a The crowded cellular milieu affect molecular diffusion through hard (occluded space) and soft (weak, non-specific) interactions. Multiple methods have been developed to measure diffusion coefficients at physiological protein concentrations within cells, each with its limitations. Here, we show that Line-FRAP, combined with rigours data analysis, is able to determine diffusion coefficients in a variety of environments, from in vitro to in vivo. The use of Line mode greatly improves time resolution of FRAP data acquisition, from 20-100 Hz in the classical mode to 800 Hz in the line mode. This improves data analysis, as intensity and radius of the bleach at the first post-bleach frame is critical. We evaluated the method on different proteins labelled chemically or fused to YFP in a wide range of environments. The diffusion coefficients measured in HeLa and in E. coli were ~2.5-fold and 15-fold slower than in buffer, and were comparable to previously published data. Increasing the osmotic pressure on E. coli further decreases diffusion, to the point at which proteins virtually stop moving. The method presented here, which requires a confocal microscope equipped with dual scanners, can be applied to study a large range of molecules with different sizes, and provides robust results in a wide range of environments and protein concentrations for fast diffusing molecules. 
650 4 |a eukaryotic cell 
650 4 |a FRAP 
650 4 |a macromolecular crowding 
650 4 |a prokaryotic cell 
650 4 |a protein diffusion 
700 1 |a Marciano, Shir  |e VerfasserIn  |4 aut 
700 1 |a Nunes-Alves, Ariane  |e VerfasserIn  |0 (DE-588)1214207375  |0 (DE-627)1725177315  |4 aut 
700 1 |a Kiss, Vladimir  |e VerfasserIn  |4 aut 
700 1 |a Wade, Rebecca C.  |e VerfasserIn  |0 (DE-588)102801774X  |0 (DE-627)730136000  |0 (DE-576)276591402  |4 aut 
700 1 |a Schreiber, Gideon  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Journal of molecular biology  |d Amsterdam [u.a.] : Elsevier, 1959  |g 433(2021), 9, Artikel-ID 166898, Seite 1-20  |h Online-Ressource  |w (DE-627)222605472  |w (DE-600)1355192-9  |w (DE-576)094059837  |x 1089-8638  |7 nnas  |a Line-FRAP, a versatile method to measure diffusion rates in vitro and in vivo 
773 1 8 |g volume:433  |g year:2021  |g number:9  |g elocationid:166898  |g pages:1-20  |g extent:20  |a Line-FRAP, a versatile method to measure diffusion rates in vitro and in vivo 
856 4 0 |u https://doi.org/10.1016/j.jmb.2021.166898  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0022283621000929  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20210609 
993 |a Article 
994 |a 2021 
998 |g 102801774X  |a Wade, Rebecca C.  |m 102801774X:Wade, Rebecca C.  |d 140000  |e 140000PW102801774X  |k 0/140000/  |p 5 
998 |g 1214207375  |a Nunes-Alves, Ariane  |m 1214207375:Nunes-Alves, Ariane  |p 3 
999 |a KXP-PPN1760107808  |e 3936250677 
BIB |a Y 
SER |a journal 
JSO |a {"title":[{"title":"Line-FRAP, a versatile method to measure diffusion rates in vitro and in vivo","title_sort":"Line-FRAP, a versatile method to measure diffusion rates in vitro and in vivo"}],"person":[{"display":"Dey, Debabrata","family":"Dey","given":"Debabrata","role":"aut"},{"display":"Marciano, Shir","role":"aut","given":"Shir","family":"Marciano"},{"display":"Nunes-Alves, Ariane","role":"aut","given":"Ariane","family":"Nunes-Alves"},{"family":"Kiss","role":"aut","given":"Vladimir","display":"Kiss, Vladimir"},{"display":"Wade, Rebecca C.","family":"Wade","role":"aut","given":"Rebecca C."},{"role":"aut","given":"Gideon","family":"Schreiber","display":"Schreiber, Gideon"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"physDesc":[{"extent":"20 S."}],"language":["eng"],"origin":[{"dateIssuedDisp":"27 February 2021","dateIssuedKey":"2021"}],"id":{"eki":["1760107808"],"doi":["10.1016/j.jmb.2021.166898"]},"recId":"1760107808","name":{"displayForm":["Debabrata Dey, Shir Marciano, Ariane Nunes-Alves, Vladimir Kiss, Rebecca C. Wade and Gideon Schreiber"]},"note":["Gesehen am 09.06.2021"],"relHost":[{"origin":[{"publisherPlace":"Amsterdam [u.a.] ; London","dateIssuedDisp":"1959-","dateIssuedKey":"1959","publisher":"Elsevier ; Academic Press"}],"id":{"zdb":["1355192-9"],"issn":["1089-8638"],"eki":["222605472"]},"part":{"pages":"1-20","volume":"433","text":"433(2021), 9, Artikel-ID 166898, Seite 1-20","extent":"20","issue":"9","year":"2021"},"recId":"222605472","disp":"Line-FRAP, a versatile method to measure diffusion rates in vitro and in vivoJournal of molecular biology","title":[{"title_sort":"Journal of molecular biology","title":"Journal of molecular biology","subtitle":"JMB"}],"note":["Gesehen am 08.03.11"],"titleAlt":[{"title":"JMB"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"pubHistory":["1.1959 -"],"language":["eng"],"physDesc":[{"extent":"Online-Ressource"}]}]} 
SRT |a DEYDEBABRALINEFRAPAV2720