The accuracy and responsiveness of continuous noninvasive arterial pressure during rapid ventricular pacing for transcatheter aortic valve replacement

Background: The accuracy of measurement of the continuous noninvasive arterial blood pressure (CNAP) technique is unknown during sudden cardiocirculatory arrest. - Methods: In 33 patients undergoing elective transfemoral aortic valve implantation procedures under analgesic sedation, invasive arteria...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Schramm, Christoph (VerfasserIn) , Huber, Anja (VerfasserIn) , Plaschke, Konstanze (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: May 17, 2013
In: Anesthesia & analgesia
Year: 2013, Jahrgang: 117, Heft: 1, Pages: 76-82
ISSN:1526-7598
DOI:10.1213/ANE.0b013e3182910df5
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1213/ANE.0b013e3182910df5
Verlag, lizenzpflichtig, Volltext: https://journals.lww.com/anesthesia-analgesia/Fulltext/2013/07000/The_Accuracy_and_Responsiveness_of_Continuous.13.aspx
Volltext
Verfasserangaben:Christoph Schramm, Anja Huber, and Konstanze Plaschke

MARC

LEADER 00000caa a2200000 c 4500
001 1763152006
003 DE-627
005 20220820021236.0
007 cr uuu---uuuuu
008 210719s2013 xx |||||o 00| ||eng c
024 7 |a 10.1213/ANE.0b013e3182910df5  |2 doi 
035 |a (DE-627)1763152006 
035 |a (DE-599)KXP1763152006 
035 |a (OCoLC)1341419613 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Schramm, Christoph  |e VerfasserIn  |0 (DE-588)1071861395  |0 (DE-627)826484778  |0 (DE-576)433375507  |4 aut 
245 1 4 |a The accuracy and responsiveness of continuous noninvasive arterial pressure during rapid ventricular pacing for transcatheter aortic valve replacement  |c Christoph Schramm, Anja Huber, and Konstanze Plaschke 
264 1 |c May 17, 2013 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 19.07.2021 
520 |a Background: The accuracy of measurement of the continuous noninvasive arterial blood pressure (CNAP) technique is unknown during sudden cardiocirculatory arrest. - Methods: In 33 patients undergoing elective transfemoral aortic valve implantation procedures under analgesic sedation, invasive arterial blood pressure (IAP) was compared with a CNAP device during episodes of severe hypotension (functional cardiocirculatory arrests by rapid pacing) and the remaining time without severe hypotension. Systolic, diastolic, and mean pairs of blood pressure measurements were extracted for both groups and were analyzed by Bland-Altman plots. The responsiveness of the CNAP technique was assessed in the various phases of severe hypotension concerning time and amplitude of changes. - Results: Overall CNAP accuracy (bias), calculated by subtracting IAP from CNAP, was −6.3 ± 18.9, 7.4 ± 10.5, and 4.0 ± 11.3 mm Hg (mean ± SD, systolic, diastolic, and mean). Bias increased during episodes of severe hypotension to 11.8 ± 14.5, 13.8 ± 12.4, and 12.9 ± 12.4 mm Hg. The percentage of agreements (95% confidence interval) between the blood pressure pairs with a difference ≤15 mm Hg was 58.5% (57.9-58.6), 75.8% (75.5-76.0), 82.2% (81.9-82.4; systolic, diastolic, mean) for all data and 56.4% (54.2-58.9; P = 0.71), 53.2%* (51.1-56.0), and 57.4%* (56.3-59.1; *P < 0.001) during rapid pacing. The responsiveness of mean CNAP and mean IAP did not differ significantly during the various phases of rapid pacing. - Conclusions: The stand-alone CNAP monitor (model 500at, software V3.5) accurately and rapidly measures the changes of blood pressure that occur during sudden development of cardiocirculatory arrest and recovery to baseline blood pressures. CNAP monitors the duration of the arrest. 
700 1 |a Huber, Anja  |d 1987-  |e VerfasserIn  |0 (DE-588)104708550X  |0 (DE-627)777541491  |0 (DE-576)400386801  |4 aut 
700 1 |a Plaschke, Konstanze  |e VerfasserIn  |0 (DE-588)1058094637  |0 (DE-627)79637919X  |0 (DE-576)171750365  |4 aut 
773 0 8 |i Enthalten in  |t Anesthesia & analgesia  |d Baltimore, Md. : Williams & Wilkins, 1957  |g 117(2013), 1, Seite 76-82  |h Online-Ressource  |w (DE-627)315974273  |w (DE-600)2018275-2  |w (DE-576)093890915  |x 1526-7598  |7 nnas  |a The accuracy and responsiveness of continuous noninvasive arterial pressure during rapid ventricular pacing for transcatheter aortic valve replacement 
773 1 8 |g volume:117  |g year:2013  |g number:1  |g pages:76-82  |g extent:7  |a The accuracy and responsiveness of continuous noninvasive arterial pressure during rapid ventricular pacing for transcatheter aortic valve replacement 
856 4 0 |u https://doi.org/10.1213/ANE.0b013e3182910df5  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://journals.lww.com/anesthesia-analgesia/Fulltext/2013/07000/The_Accuracy_and_Responsiveness_of_Continuous.13.aspx  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20210719 
993 |a Article 
994 |a 2013 
998 |g 1058094637  |a Plaschke, Konstanze  |m 1058094637:Plaschke, Konstanze  |d 910000  |d 910300  |d 50000  |e 910000PP1058094637  |e 910300PP1058094637  |e 50000PP1058094637  |k 0/910000/  |k 1/910000/910300/  |k 0/50000/  |p 3  |y j 
998 |g 104708550X  |a Huber, Anja Carmen  |m 104708550X:Huber, Anja Carmen  |d 50000  |e 50000PH104708550X  |k 0/50000/  |p 2 
998 |g 1071861395  |a Schramm, Christoph  |m 1071861395:Schramm, Christoph  |d 910000  |d 910300  |e 910000PS1071861395  |e 910300PS1071861395  |k 0/910000/  |k 1/910000/910300/  |p 1  |x j 
999 |a KXP-PPN1763152006  |e 3955215504 
BIB |a Y 
SER |a journal 
JSO |a {"name":{"displayForm":["Christoph Schramm, Anja Huber, and Konstanze Plaschke"]},"id":{"doi":["10.1213/ANE.0b013e3182910df5"],"eki":["1763152006"]},"origin":[{"dateIssuedDisp":"May 17, 2013","dateIssuedKey":"2013"}],"relHost":[{"id":{"issn":["1526-7598"],"zdb":["2018275-2"],"eki":["315974273"]},"origin":[{"publisherPlace":"Baltimore, Md. ; [Erscheinungsort nicht ermittelbar]","dateIssuedDisp":"1957-","dateIssuedKey":"1957","publisher":"Williams & Wilkins ; Ovid"}],"physDesc":[{"extent":"Online-Ressource"}],"title":[{"title_sort":"Anesthesia & analgesia","title":"Anesthesia & analgesia","subtitle":"current researches ; journal of the International Anesthesia Research Society"}],"part":{"issue":"1","pages":"76-82","year":"2013","extent":"7","volume":"117","text":"117(2013), 1, Seite 76-82"},"titleAlt":[{"title":"Anesthesia and analgesia"}],"pubHistory":["36.1957 -"],"language":["eng"],"corporate":[{"role":"isb","display":"International Anesthesia Research Society","roleDisplay":"Herausgebendes Organ"}],"recId":"315974273","disp":"The accuracy and responsiveness of continuous noninvasive arterial pressure during rapid ventricular pacing for transcatheter aortic valve replacementAnesthesia & analgesia","type":{"bibl":"periodical","media":"Online-Ressource"},"note":["Gesehen am 24.09.2018"]}],"physDesc":[{"extent":"7 S."}],"person":[{"family":"Schramm","given":"Christoph","roleDisplay":"VerfasserIn","display":"Schramm, Christoph","role":"aut"},{"roleDisplay":"VerfasserIn","display":"Huber, Anja","role":"aut","family":"Huber","given":"Anja"},{"roleDisplay":"VerfasserIn","display":"Plaschke, Konstanze","role":"aut","family":"Plaschke","given":"Konstanze"}],"title":[{"title_sort":"accuracy and responsiveness of continuous noninvasive arterial pressure during rapid ventricular pacing for transcatheter aortic valve replacement","title":"The accuracy and responsiveness of continuous noninvasive arterial pressure during rapid ventricular pacing for transcatheter aortic valve replacement"}],"language":["eng"],"recId":"1763152006","note":["Gesehen am 19.07.2021"],"type":{"bibl":"article-journal","media":"Online-Ressource"}} 
SRT |a SCHRAMMCHRACCURACYAN1720