Accuracy of 3D printing compared with milling: a multi-center analysis of try-in dentures

Objectives - In recent years, computer-aided design/computer-aided manufacturing (CAD/CAM) has been used to produce removable complete dentures. Most workflows include fabrication of milled or 3D-printed try-in prostheses. 3D-printing accuracy is affected by laboratory-specific and operator-dependen...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Herpel, Christopher (VerfasserIn) , Finke, Dominic (VerfasserIn) , Kühle, Reinald (VerfasserIn) , Rues, Stefan (VerfasserIn) , Lux, Christopher J. (VerfasserIn) , Rammelsberg, Peter (VerfasserIn) , Schwindling, Franz Sebastian (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 24 April 2021
In: Journal of dentistry
Year: 2021, Jahrgang: 110
ISSN:1879-176X
DOI:10.1016/j.jdent.2021.103681
Online-Zugang:Verlag, Volltext: https://doi.org/10.1016/j.jdent.2021.103681
Verlag: https://www.sciencedirect.com/science/article/pii/S0300571221001020
Volltext
Verfasserangaben:Christopher Herpel, Akinori Tasaka, Shizuo Higuchi, Dominic Finke, Reinald Kühle, Kento Odaka, Stefan Rues, Christopher J. Lux, Shuichiro Yamashita, Peter Rammelsberg, Franz Sebastian Schwindling

MARC

LEADER 00000caa a2200000 c 4500
001 1763270580
003 DE-627
005 20220820021458.0
007 cr uuu---uuuuu
008 210719s2021 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.jdent.2021.103681  |2 doi 
035 |a (DE-627)1763270580 
035 |a (DE-599)KXP1763270580 
035 |a (OCoLC)1341419561 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Herpel, Christopher  |e VerfasserIn  |0 (DE-588)1233302191  |0 (DE-627)1757635084  |4 aut 
245 1 0 |a Accuracy of 3D printing compared with milling  |b a multi-center analysis of try-in dentures  |c Christopher Herpel, Akinori Tasaka, Shizuo Higuchi, Dominic Finke, Reinald Kühle, Kento Odaka, Stefan Rues, Christopher J. Lux, Shuichiro Yamashita, Peter Rammelsberg, Franz Sebastian Schwindling 
246 3 0 |a Three, ThreeD 
246 3 3 |a Accuracy of 3 D printing compared with milling 
264 1 |c 24 April 2021 
300 |a 6 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Available online 24 April 2021 
500 |a Gesehen am 19.07.2021 
520 |a Objectives - In recent years, computer-aided design/computer-aided manufacturing (CAD/CAM) has been used to produce removable complete dentures. Most workflows include fabrication of milled or 3D-printed try-in prostheses. 3D-printing accuracy is affected by laboratory-specific and operator-dependent factors. This international five-center study sought to compare the accuracy of 3D-printed and milled try-in dentures. - Methods - The construction file of a maxillary removable complete denture was selected as a reference. Eight try-in dentures were 3D printed at each of the five centers. Each center used their own printer (Objet260 Connex, Stratasys; MAX, Asiga; Anycubic Photon, Anycubic 3D; PRO2, Asiga and cara Print 4.0, Kulzer) along with their own material, printing settings, post-processing and light-curing parameters. At center 2, eight try-in dentures were milled to serve as a benchmark (PrograMill PM7, Ivoclar Vivadent). Dentures were scanned and aligned to the reference file using best-fit algorithms. Geometric accuracy was analyzed using the root mean square value (trueness) and standard deviation (precision) of the distributed absolute mesh deviations. Mean values of the five sets of printed dentures and the single set of milled dentures were compared. - Results - Milled dentures showed a mean trueness of 65±6μm and a mean precision of 48±5μm. Thus, they were significantly more accurate than the 3D-printed dentures in four out of five centers. In mean absolute numbers, 3D printing was less true than milling by 17-89μm and less precise by 8-66μm. - Conclusions - Although milling remains the benchmark technique for accuracy, differences between milled and 3D-printed dentures were non-significant for one printing center. Furthermore, the overall performance of 3D printing at all centers was within a clinically acceptable range for try-in prostheses. - Clinical significance - The accuracy of 3D printing varies widely between and within laboratories but nonetheless lies within the range of accuracy of conventional manufacturing methods. 
650 4 |a 3D printing 
650 4 |a Accuracy 
650 4 |a CAD/CAM 
650 4 |a Digital dentistry 
650 4 |a Rapid prototyping 
650 4 |a Try-in 
700 1 |a Finke, Dominic  |d 1990-  |e VerfasserIn  |0 (DE-588)1156855993  |0 (DE-627)1019826592  |0 (DE-576)502471409  |4 aut 
700 1 |a Kühle, Reinald  |d 1984-  |e VerfasserIn  |0 (DE-588)1106415639  |0 (DE-627)863142214  |0 (DE-576)474109267  |4 aut 
700 1 |a Rues, Stefan  |e VerfasserIn  |0 (DE-588)1054444927  |0 (DE-627)792098331  |0 (DE-576)410292168  |4 aut 
700 1 |a Lux, Christopher J.  |d 1969-  |e VerfasserIn  |0 (DE-588)121600114  |0 (DE-627)081413815  |0 (DE-576)292792549  |4 aut 
700 1 |a Rammelsberg, Peter  |d 1959-  |e VerfasserIn  |0 (DE-588)122469836  |0 (DE-627)705920836  |0 (DE-576)293285640  |4 aut 
700 1 |a Schwindling, Franz Sebastian  |d 1986-  |e VerfasserIn  |0 (DE-588)1036843572  |0 (DE-627)751703613  |0 (DE-576)38697926X  |4 aut 
773 0 8 |i Enthalten in  |t Journal of dentistry  |d Amsterdam [u.a.] : Elsevier Science, 1972  |g 110(2021) vom: Juli, Artikel-ID 103681  |h Online-Ressource  |w (DE-627)320456757  |w (DE-600)2006760-4  |w (DE-576)09101770X  |x 1879-176X  |7 nnas  |a Accuracy of 3D printing compared with milling a multi-center analysis of try-in dentures 
773 1 8 |g volume:110  |g year:2021  |g month:07  |g elocationid:103681  |g extent:6  |a Accuracy of 3D printing compared with milling a multi-center analysis of try-in dentures 
856 4 0 |u https://doi.org/10.1016/j.jdent.2021.103681  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0300571221001020  |x Verlag 
951 |a AR 
992 |a 20210719 
993 |a Article 
994 |a 2021 
998 |g 1036843572  |a Schwindling, Franz Sebastian  |m 1036843572:Schwindling, Franz Sebastian  |d 910000  |d 910800  |d 50000  |e 910000PS1036843572  |e 910800PS1036843572  |e 50000PS1036843572  |k 0/910000/  |k 1/910000/910800/  |k 0/50000/  |p 11  |y j 
998 |g 122469836  |a Rammelsberg, Peter  |m 122469836:Rammelsberg, Peter  |d 910000  |d 910800  |e 910000PR122469836  |e 910800PR122469836  |k 0/910000/  |k 1/910000/910800/  |p 10 
998 |g 121600114  |a Lux, Christopher J.  |m 121600114:Lux, Christopher J.  |d 910000  |d 910800  |e 910000PL121600114  |e 910800PL121600114  |k 0/910000/  |k 1/910000/910800/  |p 8 
998 |g 1054444927  |a Rues, Stefan  |m 1054444927:Rues, Stefan  |d 910000  |d 910800  |e 910000PR1054444927  |e 910800PR1054444927  |k 0/910000/  |k 1/910000/910800/  |p 7 
998 |g 1106415639  |a Kühle, Reinald  |m 1106415639:Kühle, Reinald  |d 910000  |d 910800  |e 910000PK1106415639  |e 910800PK1106415639  |k 0/910000/  |k 1/910000/910800/  |p 5 
998 |g 1156855993  |a Finke, Dominic  |m 1156855993:Finke, Dominic  |p 4 
998 |g 1233302191  |a Herpel, Christopher  |m 1233302191:Herpel, Christopher  |d 910000  |d 910800  |e 910000PH1233302191  |e 910800PH1233302191  |k 0/910000/  |k 1/910000/910800/  |p 1  |x j 
999 |a KXP-PPN1763270580  |e 3955478270 
BIB |a Y 
SER |a journal 
JSO |a {"person":[{"given":"Christopher","role":"aut","display":"Herpel, Christopher","family":"Herpel","roleDisplay":"VerfasserIn"},{"family":"Finke","roleDisplay":"VerfasserIn","display":"Finke, Dominic","role":"aut","given":"Dominic"},{"roleDisplay":"VerfasserIn","family":"Kühle","role":"aut","display":"Kühle, Reinald","given":"Reinald"},{"given":"Stefan","display":"Rues, Stefan","role":"aut","roleDisplay":"VerfasserIn","family":"Rues"},{"family":"Lux","roleDisplay":"VerfasserIn","given":"Christopher J.","display":"Lux, Christopher J.","role":"aut"},{"family":"Rammelsberg","roleDisplay":"VerfasserIn","role":"aut","display":"Rammelsberg, Peter","given":"Peter"},{"given":"Franz Sebastian","display":"Schwindling, Franz Sebastian","role":"aut","roleDisplay":"VerfasserIn","family":"Schwindling"}],"relHost":[{"recId":"320456757","pubHistory":["1.1972 -"],"type":{"media":"Online-Ressource","bibl":"periodical"},"origin":[{"publisher":"Elsevier Science","dateIssuedKey":"1972","publisherPlace":"Amsterdam [u.a.]","dateIssuedDisp":"1972-"}],"language":["eng"],"physDesc":[{"extent":"Online-Ressource"}],"part":{"volume":"110","text":"110(2021) vom: Juli, Artikel-ID 103681","extent":"6","year":"2021"},"title":[{"title":"Journal of dentistry","title_sort":"Journal of dentistry"}],"id":{"zdb":["2006760-4"],"eki":["320456757"],"issn":["1879-176X"]},"disp":"Accuracy of 3D printing compared with milling a multi-center analysis of try-in denturesJournal of dentistry","note":["Gesehen am 04.05.07"]}],"recId":"1763270580","titleAlt":[{"title":"Accuracy of 3 D printing compared with milling"}],"origin":[{"dateIssuedKey":"2021","dateIssuedDisp":"24 April 2021"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"physDesc":[{"extent":"6 S."}],"name":{"displayForm":["Christopher Herpel, Akinori Tasaka, Shizuo Higuchi, Dominic Finke, Reinald Kühle, Kento Odaka, Stefan Rues, Christopher J. Lux, Shuichiro Yamashita, Peter Rammelsberg, Franz Sebastian Schwindling"]},"title":[{"title_sort":"Accuracy of 3D printing compared with milling","title":"Accuracy of 3D printing compared with milling","subtitle":"a multi-center analysis of try-in dentures"}],"id":{"eki":["1763270580"],"doi":["10.1016/j.jdent.2021.103681"]},"note":["Available online 24 April 2021","Gesehen am 19.07.2021"]} 
SRT |a HERPELCHRIACCURACYOF2420