The effect of bone lavage on femoral cement penetration and interface temperature during Oxford unicompartmental knee arthroplasty with cement

Background: Aseptic loosening is the most common cause for revision unicompartmental knee arthroplasty and is associated with failure of the bone-cement or cement-implant interface. The purpose of the present study was to analyze different bone lavage techniques for the bone-cement and cement-implan...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Seeger, Jörn Bengt (VerfasserIn) , Jäger, Sebastian (VerfasserIn) , Bitsch, Rudi G. (VerfasserIn) , Mohr, G. (VerfasserIn) , Röhner, E. (VerfasserIn) , Clarius, Michael (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: January 2, 2013
In: The journal of bone & joint surgery. A, American volume
Year: 2013, Jahrgang: 95, Heft: 1, Pages: 48-53
ISSN:1535-1386
DOI:10.2106/JBJS.K.01116
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.2106/JBJS.K.01116
Verlag, lizenzpflichtig, Volltext: https://journals.lww.com/jbjsjournal/Fulltext/2013/01020/The_Effect_of_Bone_Lavage_on_Femoral_Cement.6.aspx
Volltext
Verfasserangaben:J.B. Seeger, S. Jaeger, R.G. Bitsch, G. Mohr, E. Röhner, and M. Clarius

MARC

LEADER 00000caa a2200000 c 4500
001 1766551890
003 DE-627
005 20240414193257.0
007 cr uuu---uuuuu
008 210812s2013 xx |||||o 00| ||eng c
024 7 |a 10.2106/JBJS.K.01116  |2 doi 
035 |a (DE-627)1766551890 
035 |a (DE-599)KXP1766551890 
035 |a (OCoLC)1341420602 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Seeger, Jörn Bengt  |d 1980-  |e VerfasserIn  |0 (DE-588)139009272  |0 (DE-627)703179659  |0 (DE-576)309896347  |4 aut 
245 1 4 |a The effect of bone lavage on femoral cement penetration and interface temperature during Oxford unicompartmental knee arthroplasty with cement  |c J.B. Seeger, S. Jaeger, R.G. Bitsch, G. Mohr, E. Röhner, and M. Clarius 
264 1 |c January 2, 2013 
300 |a 6 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 12.08.2021 
520 |a Background: Aseptic loosening is the most common cause for revision unicompartmental knee arthroplasty and is associated with failure of the bone-cement or cement-implant interface. The purpose of the present study was to analyze different bone lavage techniques for the bone-cement and cement-implant interfaces of the femoral component and to study the effect of these techniques on cement penetration and on interface temperature. - Methods: In an experimental cadaver study, Oxford unicompartmental knee arthroplasty was performed in twenty-four matched-paired knees to study the effect of pulsed lavage compared with syringe lavage on femoral cement penetration and interface temperature. Interface temperature, cement penetration pressure, and ligament tension forces were measured continuously during the procedure, and cement penetration was determined by performing sagittal bone cuts. - Results: Cleansing the femoral bone stock with use of pulsed lavage (Group B) led to increased femoral cement penetration (mean, 1428 mm2; 95% confidence interval, 1348 to 1508 mm2) compared with syringe lavage (Group A) (mean, 1128 mm2; 95% confidence interval, 1038 to 1219 mm2) (p < 0.001). Interface temperature was higher in Group B (mean 22.6°C; 95% confidence interval, 20.5°C to 24.1°C) than in Group A (mean, 21.0°C; 95% confidence interval, 19.4°C to 23.0°C) (p = 0.028), but temperatures never reached critical values for thermal damage to the bone. - Conclusions: Pulsed lavage leads to an increased femoral cement penetration without the risk of heat necrosis at the bone-cement interface. - Clinical Relevance: Pulsed lavage techniques should be strongly considered for use as a routine procedure for unicompartmental knee arthroplasty with cement to increase bone cement penetration of the implant. 
700 1 |a Jäger, Sebastian  |d 1975-  |e VerfasserIn  |0 (DE-588)1059313731  |0 (DE-627)79828238X  |0 (DE-576)415306647  |4 aut 
700 1 |a Bitsch, Rudi G.  |d 1970-  |e VerfasserIn  |0 (DE-588)131490060  |0 (DE-627)50981378X  |0 (DE-576)298541726  |4 aut 
700 1 |a Mohr, G.  |e VerfasserIn  |4 aut 
700 1 |a Röhner, E.  |e VerfasserIn  |4 aut 
700 1 |a Clarius, Michael  |e VerfasserIn  |0 (DE-588)1075391903  |0 (DE-627)833263951  |0 (DE-576)176466533  |4 aut 
773 0 8 |i Enthalten in  |t The journal of bone & joint surgery. A, American volume  |d Boston, Mass. : Journal, 1889  |g 95(2013), 1, Seite 48-53  |h Online-Ressource  |w (DE-627)268761485  |w (DE-600)1473137-X  |w (DE-576)077610555  |x 1535-1386  |7 nnas  |a The effect of bone lavage on femoral cement penetration and interface temperature during Oxford unicompartmental knee arthroplasty with cement 
773 1 8 |g volume:95  |g year:2013  |g number:1  |g pages:48-53  |g extent:6  |a The effect of bone lavage on femoral cement penetration and interface temperature during Oxford unicompartmental knee arthroplasty with cement 
856 4 0 |u https://doi.org/10.2106/JBJS.K.01116  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://journals.lww.com/jbjsjournal/Fulltext/2013/01020/The_Effect_of_Bone_Lavage_on_Femoral_Cement.6.aspx  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20210812 
993 |a Article 
994 |a 2013 
998 |g 1075391903  |a Clarius, Michael  |m 1075391903:Clarius, Michael  |d 50000  |e 50000PC1075391903  |k 0/50000/  |p 6  |y j 
998 |g 131490060  |a Bitsch, Rudi G.  |m 131490060:Bitsch, Rudi G.  |d 910000  |d 911460  |d 50000  |e 910000PB131490060  |e 911460PB131490060  |e 50000PB131490060  |k 0/910000/  |k 1/910000/911460/  |k 0/50000/  |p 3 
998 |g 1059313731  |a Jäger, Sebastian  |m 1059313731:Jäger, Sebastian  |d 910000  |d 911460  |e 910000PJ1059313731  |e 911460PJ1059313731  |k 0/910000/  |k 1/910000/911460/  |p 2 
999 |a KXP-PPN1766551890  |e 3966306972 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"title":[{"title_sort":"effect of bone lavage on femoral cement penetration and interface temperature during Oxford unicompartmental knee arthroplasty with cement","title":"The effect of bone lavage on femoral cement penetration and interface temperature during Oxford unicompartmental knee arthroplasty with cement"}],"name":{"displayForm":["J.B. Seeger, S. Jaeger, R.G. Bitsch, G. Mohr, E. Röhner, and M. Clarius"]},"person":[{"family":"Seeger","display":"Seeger, Jörn Bengt","given":"Jörn Bengt","role":"aut"},{"display":"Jäger, Sebastian","given":"Sebastian","role":"aut","family":"Jäger"},{"family":"Bitsch","role":"aut","given":"Rudi G.","display":"Bitsch, Rudi G."},{"family":"Mohr","given":"G.","role":"aut","display":"Mohr, G."},{"display":"Röhner, E.","role":"aut","given":"E.","family":"Röhner"},{"display":"Clarius, Michael","role":"aut","given":"Michael","family":"Clarius"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"origin":[{"dateIssuedKey":"2013","dateIssuedDisp":"January 2, 2013"}],"recId":"1766551890","relHost":[{"titleAlt":[{"title":"The journal of bone & joint surgery / A"},{"title":"JB&JS"},{"title":"The journal of bone and joint surgery"},{"title":"JBJS"},{"title":"The journal of bone and joint surgery"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"recId":"268761485","origin":[{"publisherPlace":"Boston, Mass.","dateIssuedDisp":"1889-","publisher":"Journal","dateIssuedKey":"1889"}],"corporate":[{"role":"isb","display":"American Orthopaedic Association"},{"role":"isb","display":"British Orthopaedic Association"}],"note":["Gesehen am 22.08.2023"],"disp":"The effect of bone lavage on femoral cement penetration and interface temperature during Oxford unicompartmental knee arthroplasty with cementThe journal of bone & joint surgery. A, American volume","id":{"issn":["1535-1386"],"zdb":["1473137-X"],"eki":["268761485"]},"physDesc":[{"extent":"Online-Ressource"}],"name":{"displayForm":["American Orthopaedic Association ; British Orthopaedic Association ; American Academy of Orthopaedic Surgeons"]},"pubHistory":["1.1889 -"],"language":["eng"],"part":{"volume":"95","year":"2013","text":"95(2013), 1, Seite 48-53","pages":"48-53","extent":"6","issue":"1"},"title":[{"subtitle":"JBJS","partname":"American volume","title":"The journal of bone & joint surgery","title_sort":"journal of bone & joint surgery"}]}],"note":["Gesehen am 12.08.2021"],"id":{"eki":["1766551890"],"doi":["10.2106/JBJS.K.01116"]},"physDesc":[{"extent":"6 S."}]} 
SRT |a SEEGERJOEREFFECTOFBO2201