Treatment of periprosthetic tibial plateau fractures in unicompartmental knee arthroplasty: plates versus cannulated screws
Periprosthetic tibial plateau fractures (TPF) are rare but represent a serious complication in unicompartmental knee arthroplasty. The most common treatment for these fractures is osteosynthesis with cannulated screws or plates. The aim of this study was to evaluate two different treatment options f...
Gespeichert in:
| Hauptverfasser: | , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
2013
|
| In: |
Archives of orthopaedic and trauma surgery
Year: 2013, Jahrgang: 133, Heft: 2, Pages: 253-257 |
| ISSN: | 1434-3916 |
| DOI: | 10.1007/s00402-012-1649-6 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1007/s00402-012-1649-6 |
| Verfasserangaben: | Joern Bengt Seeger, S. Jaeger, E. Röhner, H. Dierkes, G. Wassilew, M. Clarius |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 176655427X | ||
| 003 | DE-627 | ||
| 005 | 20220820033900.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 210812s2013 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1007/s00402-012-1649-6 |2 doi | |
| 035 | |a (DE-627)176655427X | ||
| 035 | |a (DE-599)KXP176655427X | ||
| 035 | |a (OCoLC)1341420438 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Seeger, Jörn Bengt |d 1980- |e VerfasserIn |0 (DE-588)139009272 |0 (DE-627)703179659 |0 (DE-576)309896347 |4 aut | |
| 245 | 1 | 0 | |a Treatment of periprosthetic tibial plateau fractures in unicompartmental knee arthroplasty |b plates versus cannulated screws |c Joern Bengt Seeger, S. Jaeger, E. Röhner, H. Dierkes, G. Wassilew, M. Clarius |
| 264 | 1 | |c 2013 | |
| 300 | |a 5 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Published online: 3 November 2012 | ||
| 500 | |a Gesehen am 12.08.2021 | ||
| 520 | |a Periprosthetic tibial plateau fractures (TPF) are rare but represent a serious complication in unicompartmental knee arthroplasty. The most common treatment for these fractures is osteosynthesis with cannulated screws or plates. The aim of this study was to evaluate two different treatment options for periprosthetic fractures. The hypothesis was that angle-stable plates show significantly higher fracture loads than fixation with cannulated screws. | ||
| 700 | 1 | |a Jäger, Sebastian |d 1975- |e VerfasserIn |0 (DE-588)1059313731 |0 (DE-627)79828238X |0 (DE-576)415306647 |4 aut | |
| 700 | 1 | |a Röhner, E. |e VerfasserIn |4 aut | |
| 700 | 1 | |a Dierkes, H. |e VerfasserIn |4 aut | |
| 700 | 1 | |a Wassilew, G. |e VerfasserIn |4 aut | |
| 700 | 1 | |a Clarius, Michael |e VerfasserIn |0 (DE-588)1075391903 |0 (DE-627)833263951 |0 (DE-576)176466533 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Archives of orthopaedic and trauma surgery |d Berlin : Springer, 1989 |g 133(2013), 2, Seite 253-257 |h Online-Ressource |w (DE-627)253390087 |w (DE-600)1458452-9 |w (DE-576)072283297 |x 1434-3916 |7 nnas |a Treatment of periprosthetic tibial plateau fractures in unicompartmental knee arthroplasty plates versus cannulated screws |
| 773 | 1 | 8 | |g volume:133 |g year:2013 |g number:2 |g pages:253-257 |g extent:5 |a Treatment of periprosthetic tibial plateau fractures in unicompartmental knee arthroplasty plates versus cannulated screws |
| 856 | 4 | 0 | |u https://doi.org/10.1007/s00402-012-1649-6 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20210812 | ||
| 993 | |a Article | ||
| 994 | |a 2013 | ||
| 998 | |g 1075391903 |a Clarius, Michael |m 1075391903:Clarius, Michael |d 50000 |e 50000PC1075391903 |k 0/50000/ |p 6 |y j | ||
| 998 | |g 1059313731 |a Jäger, Sebastian |m 1059313731:Jäger, Sebastian |d 910000 |d 911460 |e 910000PJ1059313731 |e 911460PJ1059313731 |k 0/910000/ |k 1/910000/911460/ |p 2 | ||
| 999 | |a KXP-PPN176655427X |e 3966314029 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"note":["Published online: 3 November 2012","Gesehen am 12.08.2021"],"relHost":[{"note":["Gesehen am 28.03.25","Fortsetzung der Druck-Ausgabe"],"part":{"volume":"133","text":"133(2013), 2, Seite 253-257","pages":"253-257","year":"2013","issue":"2","extent":"5"},"id":{"eki":["253390087"],"zdb":["1458452-9"],"issn":["1434-3916"]},"physDesc":[{"extent":"Online-Ressource"}],"title":[{"title":"Archives of orthopaedic and trauma surgery","title_sort":"Archives of orthopaedic and trauma surgery"}],"origin":[{"publisherPlace":"Berlin ; Heidelberg","dateIssuedKey":"1989","dateIssuedDisp":"1989-","publisher":"Springer"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"pubHistory":["Volume 108, issue 1 (January 1989)-"],"titleAlt":[{"title":"Orthopaedic and trauma surgery"}],"language":["eng"],"disp":"Treatment of periprosthetic tibial plateau fractures in unicompartmental knee arthroplasty plates versus cannulated screwsArchives of orthopaedic and trauma surgery","recId":"253390087"}],"physDesc":[{"extent":"5 S."}],"id":{"eki":["176655427X"],"doi":["10.1007/s00402-012-1649-6"]},"type":{"bibl":"article-journal","media":"Online-Ressource"},"title":[{"title":"Treatment of periprosthetic tibial plateau fractures in unicompartmental knee arthroplasty","subtitle":"plates versus cannulated screws","title_sort":"Treatment of periprosthetic tibial plateau fractures in unicompartmental knee arthroplasty"}],"language":["eng"],"person":[{"family":"Seeger","display":"Seeger, Jörn Bengt","given":"Jörn Bengt","role":"aut"},{"display":"Jäger, Sebastian","given":"Sebastian","family":"Jäger","role":"aut"},{"given":"E.","display":"Röhner, E.","family":"Röhner","role":"aut"},{"role":"aut","display":"Dierkes, H.","given":"H.","family":"Dierkes"},{"family":"Wassilew","given":"G.","display":"Wassilew, G.","role":"aut"},{"role":"aut","display":"Clarius, Michael","given":"Michael","family":"Clarius"}],"origin":[{"dateIssuedKey":"2013","dateIssuedDisp":"2013"}],"name":{"displayForm":["Joern Bengt Seeger, S. Jaeger, E. Röhner, H. Dierkes, G. Wassilew, M. Clarius"]},"recId":"176655427X"} | ||
| SRT | |a SEEGERJOERTREATMENTO2013 | ||