Treatment of periprosthetic tibial plateau fractures in unicompartmental knee arthroplasty: plates versus cannulated screws

Periprosthetic tibial plateau fractures (TPF) are rare but represent a serious complication in unicompartmental knee arthroplasty. The most common treatment for these fractures is osteosynthesis with cannulated screws or plates. The aim of this study was to evaluate two different treatment options f...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Seeger, Jörn Bengt (VerfasserIn) , Jäger, Sebastian (VerfasserIn) , Röhner, E. (VerfasserIn) , Dierkes, H. (VerfasserIn) , Wassilew, G. (VerfasserIn) , Clarius, Michael (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2013
In: Archives of orthopaedic and trauma surgery
Year: 2013, Jahrgang: 133, Heft: 2, Pages: 253-257
ISSN:1434-3916
DOI:10.1007/s00402-012-1649-6
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1007/s00402-012-1649-6
Volltext
Verfasserangaben:Joern Bengt Seeger, S. Jaeger, E. Röhner, H. Dierkes, G. Wassilew, M. Clarius

MARC

LEADER 00000caa a2200000 c 4500
001 176655427X
003 DE-627
005 20220820033900.0
007 cr uuu---uuuuu
008 210812s2013 xx |||||o 00| ||eng c
024 7 |a 10.1007/s00402-012-1649-6  |2 doi 
035 |a (DE-627)176655427X 
035 |a (DE-599)KXP176655427X 
035 |a (OCoLC)1341420438 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Seeger, Jörn Bengt  |d 1980-  |e VerfasserIn  |0 (DE-588)139009272  |0 (DE-627)703179659  |0 (DE-576)309896347  |4 aut 
245 1 0 |a Treatment of periprosthetic tibial plateau fractures in unicompartmental knee arthroplasty  |b plates versus cannulated screws  |c Joern Bengt Seeger, S. Jaeger, E. Röhner, H. Dierkes, G. Wassilew, M. Clarius 
264 1 |c 2013 
300 |a 5 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Published online: 3 November 2012 
500 |a Gesehen am 12.08.2021 
520 |a Periprosthetic tibial plateau fractures (TPF) are rare but represent a serious complication in unicompartmental knee arthroplasty. The most common treatment for these fractures is osteosynthesis with cannulated screws or plates. The aim of this study was to evaluate two different treatment options for periprosthetic fractures. The hypothesis was that angle-stable plates show significantly higher fracture loads than fixation with cannulated screws. 
700 1 |a Jäger, Sebastian  |d 1975-  |e VerfasserIn  |0 (DE-588)1059313731  |0 (DE-627)79828238X  |0 (DE-576)415306647  |4 aut 
700 1 |a Röhner, E.  |e VerfasserIn  |4 aut 
700 1 |a Dierkes, H.  |e VerfasserIn  |4 aut 
700 1 |a Wassilew, G.  |e VerfasserIn  |4 aut 
700 1 |a Clarius, Michael  |e VerfasserIn  |0 (DE-588)1075391903  |0 (DE-627)833263951  |0 (DE-576)176466533  |4 aut 
773 0 8 |i Enthalten in  |t Archives of orthopaedic and trauma surgery  |d Berlin : Springer, 1989  |g 133(2013), 2, Seite 253-257  |h Online-Ressource  |w (DE-627)253390087  |w (DE-600)1458452-9  |w (DE-576)072283297  |x 1434-3916  |7 nnas  |a Treatment of periprosthetic tibial plateau fractures in unicompartmental knee arthroplasty plates versus cannulated screws 
773 1 8 |g volume:133  |g year:2013  |g number:2  |g pages:253-257  |g extent:5  |a Treatment of periprosthetic tibial plateau fractures in unicompartmental knee arthroplasty plates versus cannulated screws 
856 4 0 |u https://doi.org/10.1007/s00402-012-1649-6  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20210812 
993 |a Article 
994 |a 2013 
998 |g 1075391903  |a Clarius, Michael  |m 1075391903:Clarius, Michael  |d 50000  |e 50000PC1075391903  |k 0/50000/  |p 6  |y j 
998 |g 1059313731  |a Jäger, Sebastian  |m 1059313731:Jäger, Sebastian  |d 910000  |d 911460  |e 910000PJ1059313731  |e 911460PJ1059313731  |k 0/910000/  |k 1/910000/911460/  |p 2 
999 |a KXP-PPN176655427X  |e 3966314029 
BIB |a Y 
SER |a journal 
JSO |a {"note":["Published online: 3 November 2012","Gesehen am 12.08.2021"],"relHost":[{"note":["Gesehen am 28.03.25","Fortsetzung der Druck-Ausgabe"],"part":{"volume":"133","text":"133(2013), 2, Seite 253-257","pages":"253-257","year":"2013","issue":"2","extent":"5"},"id":{"eki":["253390087"],"zdb":["1458452-9"],"issn":["1434-3916"]},"physDesc":[{"extent":"Online-Ressource"}],"title":[{"title":"Archives of orthopaedic and trauma surgery","title_sort":"Archives of orthopaedic and trauma surgery"}],"origin":[{"publisherPlace":"Berlin ; Heidelberg","dateIssuedKey":"1989","dateIssuedDisp":"1989-","publisher":"Springer"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"pubHistory":["Volume 108, issue 1 (January 1989)-"],"titleAlt":[{"title":"Orthopaedic and trauma surgery"}],"language":["eng"],"disp":"Treatment of periprosthetic tibial plateau fractures in unicompartmental knee arthroplasty plates versus cannulated screwsArchives of orthopaedic and trauma surgery","recId":"253390087"}],"physDesc":[{"extent":"5 S."}],"id":{"eki":["176655427X"],"doi":["10.1007/s00402-012-1649-6"]},"type":{"bibl":"article-journal","media":"Online-Ressource"},"title":[{"title":"Treatment of periprosthetic tibial plateau fractures in unicompartmental knee arthroplasty","subtitle":"plates versus cannulated screws","title_sort":"Treatment of periprosthetic tibial plateau fractures in unicompartmental knee arthroplasty"}],"language":["eng"],"person":[{"family":"Seeger","display":"Seeger, Jörn Bengt","given":"Jörn Bengt","role":"aut"},{"display":"Jäger, Sebastian","given":"Sebastian","family":"Jäger","role":"aut"},{"given":"E.","display":"Röhner, E.","family":"Röhner","role":"aut"},{"role":"aut","display":"Dierkes, H.","given":"H.","family":"Dierkes"},{"family":"Wassilew","given":"G.","display":"Wassilew, G.","role":"aut"},{"role":"aut","display":"Clarius, Michael","given":"Michael","family":"Clarius"}],"origin":[{"dateIssuedKey":"2013","dateIssuedDisp":"2013"}],"name":{"displayForm":["Joern Bengt Seeger, S. Jaeger, E. Röhner, H. Dierkes, G. Wassilew, M. Clarius"]},"recId":"176655427X"} 
SRT |a SEEGERJOERTREATMENTO2013