A tensionable suture-based cerclage is an alternative to stainless steel cerclage fixation for stabilization of a humeral osteotomy during shoulder arthroplasty

Introduction: - Fixation of periprosthetic humeral fractures is most commonly obtained with steel-based wires or cables; however, disadvantages with these constructs are numerous. Suture-based cerclages offer the advantage of easy handling, less radiographic interference, and risk of metall...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Denard, Patrick (VerfasserIn) , Nolte, Philip-Christian (VerfasserIn) , Millett, Peter J. (VerfasserIn) , Adams, Christopher R. (VerfasserIn) , Liebler, Stephenie A. H. (VerfasserIn) , Rego, George (VerfasserIn) , Higgins, Laurence D. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: June 15, 2021
In: Journal of the American Academy of Orthopaedic Surgeons
Year: 2021, Jahrgang: 29, Heft: 12, Pages: 609-617
ISSN:1940-5480
DOI:10.5435/JAAOS-D-20-00047
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.5435/JAAOS-D-20-00047
Verlag, lizenzpflichtig, Volltext: https://journals.lww.com/jaaos/Abstract/2021/06150/A_Tensionable_Suture_based_Cerclage_Is_an.10.aspx
Volltext
Verfasserangaben:Patrick J. Denard, Philip-C. Nolte, Peter J. Millett, Christopher R. Adams, Stephenie A.H. Liebler, George Rego, Laurence D. Higgins

MARC

LEADER 00000caa a22000002c 4500
001 177218344X
003 DE-627
005 20240414193407.0
007 cr uuu---uuuuu
008 211001s2021 xx |||||o 00| ||eng c
024 7 |a 10.5435/JAAOS-D-20-00047  |2 doi 
035 |a (DE-627)177218344X 
035 |a (DE-599)KXP177218344X 
035 |a (OCoLC)1341421606 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Denard, Patrick  |e VerfasserIn  |0 (DE-588)1223220486  |0 (DE-627)174266413X  |4 aut 
245 1 2 |a A tensionable suture-based cerclage is an alternative to stainless steel cerclage fixation for stabilization of a humeral osteotomy during shoulder arthroplasty  |c Patrick J. Denard, Philip-C. Nolte, Peter J. Millett, Christopher R. Adams, Stephenie A.H. Liebler, George Rego, Laurence D. Higgins 
264 1 |c June 15, 2021 
300 |a 9 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 01.10.2021 
520 |a Introduction: - Fixation of periprosthetic humeral fractures is most commonly obtained with steel-based wires or cables; however, disadvantages with these constructs are numerous. Suture-based cerclages offer the advantage of easy handling, less radiographic interference, and risk of metallosis, as well as decreased risk of cutting into the soft humeral bone. Therefore, the purpose of this study was to compare a suture-based cerclage to a stainless steel wire cerclage (SSWC) for stabilization of the humerus during shoulder arthroplasty. - Methods: - In part I of the study, SSWC fixation was compared with single-looped tape cerclage and a double-looped tape cerclage (DLTC) fixation. In part II, a subsidence test was performed on 12 cadaveric humeri. After an osteotomy, the humeri were secured with either a SSWC or DLTC. Subsequently, a metal wedge was introduced into the humerus to simulate the stem of a shoulder arthroplasty. - Results: - In part I, load to 2-mm displacement was significantly higher for the DLTC construct compared with the SSWC construct (2,401 ± 483 N versus 750 ± 33 N; P < 0.0001). Load to failure was 935 ± 143 N with the SSWC, 1,737 ± 113 N with the single-looped tape cerclage, and 4,360 ± 463 N with the DLTC constructs, and all differences were statistically significant (P < 0.05). In part II, load at 20-mm subsidence was higher for the DLTC (320 ± 274 N) compared with the SSWC (247 ± 137 N), but no significant difference was observed (P > 0.05). However, gap displacement at 20 mm subsidence was significantly lower with the DLTC construct (0.33 ± 0.31 mm versus 0.77 ± 0.23 mm; P = 0.009). Load to failure was higher with the DLTC construct compared with the SSWC construct (4,447 ± 2,325 N versus 1,880 ± 1,089 N; P = 0.032), but the final gap displacement did not differ significantly (DLTC 5.23 ± 6.63 mm versus SSWC 6.03 ± 8.82 mm; P > 0.05). - Discussion: - A DLTC has higher load to failure and trends toward lower gap displacement compared with a SSWC. The DLTC construct may therefore be a viable alternative for fixation of periprosthetic fractures or osteotomies of the humeral shaft during shoulder arthroplasty. 
700 1 |a Nolte, Philip-Christian  |d 1987-  |e VerfasserIn  |0 (DE-588)105698712X  |0 (DE-627)794361757  |0 (DE-576)41297102X  |4 aut 
700 1 |a Millett, Peter J.  |e VerfasserIn  |4 aut 
700 1 |a Adams, Christopher R.  |e VerfasserIn  |4 aut 
700 1 |a Liebler, Stephenie A. H.  |e VerfasserIn  |4 aut 
700 1 |a Rego, George  |e VerfasserIn  |4 aut 
700 1 |a Higgins, Laurence D.  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |a American Academy of Orthopaedic Surgeons  |t Journal of the American Academy of Orthopaedic Surgeons  |d Rosemont, Ill. : AAOS, 1993  |g 29(2021), 12, Seite 609-617  |h Online-Ressource  |w (DE-627)347041965  |w (DE-600)2078484-3  |w (DE-576)309204488  |x 1940-5480  |7 nnas 
773 1 8 |g volume:29  |g year:2021  |g number:12  |g pages:609-617  |g extent:9  |a A tensionable suture-based cerclage is an alternative to stainless steel cerclage fixation for stabilization of a humeral osteotomy during shoulder arthroplasty 
856 4 0 |u https://doi.org/10.5435/JAAOS-D-20-00047  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://journals.lww.com/jaaos/Abstract/2021/06150/A_Tensionable_Suture_based_Cerclage_Is_an.10.aspx  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20211001 
993 |a Article 
994 |a 2021 
998 |g 105698712X  |a Nolte, Philip-Christian  |m 105698712X:Nolte, Philip-Christian  |d 50000  |e 50000PN105698712X  |k 0/50000/  |p 2 
999 |a KXP-PPN177218344X  |e 3982768713 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"disp":"American Academy of Orthopaedic SurgeonsJournal of the American Academy of Orthopaedic Surgeons","type":{"media":"Online-Ressource","bibl":"periodical"},"note":["Gesehen am 28. Mai 2019"],"recId":"347041965","corporate":[{"display":"American Academy of Orthopaedic Surgeons","roleDisplay":"VerfasserIn","role":"aut"}],"language":["eng"],"pubHistory":["1.1993 -"],"titleAlt":[{"title":"JAAOS"}],"part":{"text":"29(2021), 12, Seite 609-617","volume":"29","extent":"9","year":"2021","pages":"609-617","issue":"12"},"title":[{"title":"Journal of the American Academy of Orthopaedic Surgeons","subtitle":"JAAOS","title_sort":"Journal of the American Academy of Orthopaedic Surgeons"}],"physDesc":[{"extent":"Online-Ressource"}],"origin":[{"dateIssuedKey":"1993","publisher":"AAOS","dateIssuedDisp":"1993-","publisherPlace":"Rosemont, Ill."}],"id":{"zdb":["2078484-3"],"eki":["347041965"],"issn":["1940-5480"]}}],"physDesc":[{"extent":"9 S."}],"id":{"eki":["177218344X"],"doi":["10.5435/JAAOS-D-20-00047"]},"origin":[{"dateIssuedKey":"2021","dateIssuedDisp":"June 15, 2021"}],"name":{"displayForm":["Patrick J. Denard, Philip-C. Nolte, Peter J. Millett, Christopher R. Adams, Stephenie A.H. Liebler, George Rego, Laurence D. Higgins"]},"recId":"177218344X","language":["eng"],"note":["Gesehen am 01.10.2021"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"title":[{"title":"A tensionable suture-based cerclage is an alternative to stainless steel cerclage fixation for stabilization of a humeral osteotomy during shoulder arthroplasty","title_sort":"tensionable suture-based cerclage is an alternative to stainless steel cerclage fixation for stabilization of a humeral osteotomy during shoulder arthroplasty"}],"person":[{"given":"Patrick","family":"Denard","role":"aut","roleDisplay":"VerfasserIn","display":"Denard, Patrick"},{"family":"Nolte","given":"Philip-Christian","display":"Nolte, Philip-Christian","roleDisplay":"VerfasserIn","role":"aut"},{"family":"Millett","given":"Peter J.","display":"Millett, Peter J.","roleDisplay":"VerfasserIn","role":"aut"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Adams, Christopher R.","given":"Christopher R.","family":"Adams"},{"role":"aut","display":"Liebler, Stephenie A. H.","roleDisplay":"VerfasserIn","given":"Stephenie A. H.","family":"Liebler"},{"given":"George","family":"Rego","role":"aut","roleDisplay":"VerfasserIn","display":"Rego, George"},{"roleDisplay":"VerfasserIn","display":"Higgins, Laurence D.","role":"aut","family":"Higgins","given":"Laurence D."}]} 
SRT |a DENARDPATRTENSIONABL1520