Predictability and image quality of low-dose cone-beam computed tomography in computer-guided implantology: an experimental study
Objectives - To investigate the predictability and image quality of low-dose cone-beam computed tomography (LD-CBCT) in computer-guided implantology. - Methods - Pig cadaver mandibles were imaged using high-definition CBCT (HD-CBCT) and LD-CBCT (HD-CBCT: 85 kV, 6 mA, 14.2 s, 767 frames, 1184 mGycm2,...
Saved in:
| Main Authors: | , , , , , , |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
9 July 2021
|
| In: |
Journal of dentistry
Year: 2021, Volume: 112, Pages: 1-7 |
| ISSN: | 1879-176X |
| DOI: | 10.1016/j.jdent.2021.103744 |
| Online Access: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.jdent.2021.103744 Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0300571221001652 |
| Author Notes: | Laura Horsch, Christos Labis, Charlotte Theresa Trebing, Dorothea Kronsteiner, Tim Hilgenfeld, Peter Rammelsberg, Franz Sebastian Schwindling |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 177418933X | ||
| 003 | DE-627 | ||
| 005 | 20240414193458.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 211015s2021 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.jdent.2021.103744 |2 doi | |
| 035 | |a (DE-627)177418933X | ||
| 035 | |a (DE-599)KXP177418933X | ||
| 035 | |a (OCoLC)1341421974 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Horsch, Laura |d 1991- |e VerfasserIn |0 (DE-588)1183802404 |0 (DE-627)1663340625 |4 aut | |
| 245 | 1 | 0 | |a Predictability and image quality of low-dose cone-beam computed tomography in computer-guided implantology |b an experimental study |c Laura Horsch, Christos Labis, Charlotte Theresa Trebing, Dorothea Kronsteiner, Tim Hilgenfeld, Peter Rammelsberg, Franz Sebastian Schwindling |
| 264 | 1 | |c 9 July 2021 | |
| 300 | |a 7 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 15.10.2021 | ||
| 520 | |a Objectives - To investigate the predictability and image quality of low-dose cone-beam computed tomography (LD-CBCT) in computer-guided implantology. - Methods - Pig cadaver mandibles were imaged using high-definition CBCT (HD-CBCT) and LD-CBCT (HD-CBCT: 85 kV, 6 mA, 14.2 s, 767 frames, 1184 mGycm2, voxel size 80 µm, effective dose 231 µSv; LD-CBCT: 85 kV, 10 mA, 2.1 s, 384 frames, 84 mGycm2, voxel size 160 µm, effective dose 16 µSv; Orthophos SL, Dentsply Sirona, Bensheim, Germany). Digital impressions were taken using intraoral scanning (IOS; Omnicam, Dentsply Sirona). Data of CBCT modalities and IOS were aligned. Forty-eight implants were planned virtually (24 implants per modality; Bone Level 4.1 × 10 mm; Straumann AG, Basel, Switzerland). Implants were inserted using templates by initial pilot drilling (“partially-guided implantation”). Implant positions were recorded using IOS. Geometric deviations between planned and definitive positions were assessed regarding implant apex, entry-point and angle. CBCT image quality was evaluated by raters twice on a four point scale. The results were exploratively compared (linear models, Mann-Whitney-U tests). - Results - Regarding implant apex, deviations were greater for LD-CBCT (mean 3.0±1.2 mm), as compared to HD-CBCT (mean 2.3±1.1 mm). For entry-point, no distinct difference was detected with a mean deviation of 1.4±0.9 mm in LD-CBCT, and 1.7±0.6 mm in HD-CBCT. Regarding angle, deviations were greater for LD-CBCT (mean 13.2±6.3°), as compared to HD-CBCT (mean 9.2±5.3°). The image quality of HD-CBCT provided to be better (mean 2.7±0.6) than that of LD-CBCT (mean 2.5±0.6). - Conclusions - Within the partially-guided approach, the results underline the potential of LD-CBCT alternatively to HD-CBCT for computer-guided implantology. Advantages of HD-CBCT need to be balanced against the higher radiation dose. | ||
| 650 | 4 | |a CBCT | |
| 650 | 4 | |a Computer-guided surgery | |
| 650 | 4 | |a Dental implant | |
| 650 | 4 | |a Diagnostic accuracy | |
| 650 | 4 | |a Intraoral scanning | |
| 650 | 4 | |a Low-dose protocol | |
| 700 | 1 | |a Labis, Christos |d 1991- |e VerfasserIn |0 (DE-588)1243274654 |0 (DE-627)1774189828 |4 aut | |
| 700 | 1 | |a Trebing, Charlotte Theresa |e VerfasserIn |0 (DE-588)1225686970 |0 (DE-627)1745534075 |4 aut | |
| 700 | 1 | |a Kronsteiner, Dorothea |d 1991- |e VerfasserIn |0 (DE-588)1155734920 |0 (DE-627)1017938512 |0 (DE-576)501817794 |4 aut | |
| 700 | 1 | |a Hilgenfeld, Tim |d 1986- |e VerfasserIn |0 (DE-588)1106261917 |0 (DE-627)862954398 |0 (DE-576)473950316 |4 aut | |
| 700 | 1 | |a Rammelsberg, Peter |d 1959- |e VerfasserIn |0 (DE-588)122469836 |0 (DE-627)705920836 |0 (DE-576)293285640 |4 aut | |
| 700 | 1 | |a Schwindling, Franz Sebastian |d 1986- |e VerfasserIn |0 (DE-588)1036843572 |0 (DE-627)751703613 |0 (DE-576)38697926X |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Journal of dentistry |d Amsterdam [u.a.] : Elsevier Science, 1972 |g 112(2021) vom: Sept., Artikel-ID 103744, Seite 1-7 |h Online-Ressource |w (DE-627)320456757 |w (DE-600)2006760-4 |w (DE-576)09101770X |x 1879-176X |7 nnas |a Predictability and image quality of low-dose cone-beam computed tomography in computer-guided implantology an experimental study |
| 773 | 1 | 8 | |g volume:112 |g year:2021 |g month:09 |g elocationid:103744 |g pages:1-7 |g extent:7 |a Predictability and image quality of low-dose cone-beam computed tomography in computer-guided implantology an experimental study |
| 856 | 4 | 0 | |u https://doi.org/10.1016/j.jdent.2021.103744 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://www.sciencedirect.com/science/article/pii/S0300571221001652 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20211015 | ||
| 993 | |a Article | ||
| 994 | |a 2021 | ||
| 998 | |g 1036843572 |a Schwindling, Franz Sebastian |m 1036843572:Schwindling, Franz Sebastian |d 910000 |d 910800 |d 50000 |e 910000PS1036843572 |e 910800PS1036843572 |e 50000PS1036843572 |k 0/910000/ |k 1/910000/910800/ |k 0/50000/ |p 7 |y j | ||
| 998 | |g 122469836 |a Rammelsberg, Peter |m 122469836:Rammelsberg, Peter |d 910000 |d 910800 |e 910000PR122469836 |e 910800PR122469836 |k 0/910000/ |k 1/910000/910800/ |p 6 | ||
| 998 | |g 1106261917 |a Hilgenfeld, Tim |m 1106261917:Hilgenfeld, Tim |d 910000 |d 911100 |d 50000 |e 910000PH1106261917 |e 911100PH1106261917 |e 50000PH1106261917 |k 0/910000/ |k 1/910000/911100/ |k 0/50000/ |p 5 | ||
| 998 | |g 1155734920 |a Kronsteiner, Dorothea |m 1155734920:Kronsteiner, Dorothea |d 50000 |e 50000PK1155734920 |k 0/50000/ |p 4 | ||
| 998 | |g 1225686970 |a Trebing, Charlotte Theresa |m 1225686970:Trebing, Charlotte Theresa |d 910000 |d 910800 |e 910000PT1225686970 |e 910800PT1225686970 |k 0/910000/ |k 1/910000/910800/ |p 3 | ||
| 998 | |g 1243274654 |a Labis, Christos |m 1243274654:Labis, Christos |d 910000 |d 910800 |e 910000PL1243274654 |e 910800PL1243274654 |k 0/910000/ |k 1/910000/910800/ |p 2 | ||
| 998 | |g 1183802404 |a Horsch, Laura |m 1183802404:Horsch, Laura |d 910000 |d 910800 |e 910000PH1183802404 |e 910800PH1183802404 |k 0/910000/ |k 1/910000/910800/ |p 1 |x j | ||
| 999 | |a KXP-PPN177418933X |e 3990322028 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"recId":"177418933X","id":{"eki":["177418933X"],"doi":["10.1016/j.jdent.2021.103744"]},"name":{"displayForm":["Laura Horsch, Christos Labis, Charlotte Theresa Trebing, Dorothea Kronsteiner, Tim Hilgenfeld, Peter Rammelsberg, Franz Sebastian Schwindling"]},"person":[{"family":"Horsch","display":"Horsch, Laura","roleDisplay":"VerfasserIn","given":"Laura","role":"aut"},{"role":"aut","given":"Christos","roleDisplay":"VerfasserIn","display":"Labis, Christos","family":"Labis"},{"family":"Trebing","roleDisplay":"VerfasserIn","given":"Charlotte Theresa","display":"Trebing, Charlotte Theresa","role":"aut"},{"family":"Kronsteiner","display":"Kronsteiner, Dorothea","roleDisplay":"VerfasserIn","given":"Dorothea","role":"aut"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Hilgenfeld, Tim","given":"Tim","family":"Hilgenfeld"},{"given":"Peter","roleDisplay":"VerfasserIn","display":"Rammelsberg, Peter","family":"Rammelsberg","role":"aut"},{"family":"Schwindling","roleDisplay":"VerfasserIn","display":"Schwindling, Franz Sebastian","given":"Franz Sebastian","role":"aut"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"title":[{"title_sort":"Predictability and image quality of low-dose cone-beam computed tomography in computer-guided implantology","title":"Predictability and image quality of low-dose cone-beam computed tomography in computer-guided implantology","subtitle":"an experimental study"}],"origin":[{"dateIssuedDisp":"9 July 2021","dateIssuedKey":"2021"}],"note":["Gesehen am 15.10.2021"],"relHost":[{"origin":[{"publisherPlace":"Amsterdam [u.a.]","dateIssuedDisp":"1972-","publisher":"Elsevier Science","dateIssuedKey":"1972"}],"pubHistory":["1.1972 -"],"id":{"zdb":["2006760-4"],"eki":["320456757"],"issn":["1879-176X"]},"recId":"320456757","disp":"Predictability and image quality of low-dose cone-beam computed tomography in computer-guided implantology an experimental studyJournal of dentistry","language":["eng"],"title":[{"title":"Journal of dentistry","title_sort":"Journal of dentistry"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"note":["Gesehen am 04.05.07"],"part":{"volume":"112","extent":"7","text":"112(2021) vom: Sept., Artikel-ID 103744, Seite 1-7","year":"2021","pages":"1-7"},"physDesc":[{"extent":"Online-Ressource"}]}],"physDesc":[{"extent":"7 S."}],"language":["eng"]} | ||
| SRT | |a HORSCHLAURPREDICTABI9202 | ||