Predictability and image quality of low-dose cone-beam computed tomography in computer-guided implantology: an experimental study

Objectives - To investigate the predictability and image quality of low-dose cone-beam computed tomography (LD-CBCT) in computer-guided implantology. - Methods - Pig cadaver mandibles were imaged using high-definition CBCT (HD-CBCT) and LD-CBCT (HD-CBCT: 85 kV, 6 mA, 14.2 s, 767 frames, 1184 mGycm2,...

Full description

Saved in:
Bibliographic Details
Main Authors: Horsch, Laura (Author) , Labis, Christos (Author) , Trebing, Charlotte Theresa (Author) , Kronsteiner, Dorothea (Author) , Hilgenfeld, Tim (Author) , Rammelsberg, Peter (Author) , Schwindling, Franz Sebastian (Author)
Format: Article (Journal)
Language:English
Published: 9 July 2021
In: Journal of dentistry
Year: 2021, Volume: 112, Pages: 1-7
ISSN:1879-176X
DOI:10.1016/j.jdent.2021.103744
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.jdent.2021.103744
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0300571221001652
Get full text
Author Notes:Laura Horsch, Christos Labis, Charlotte Theresa Trebing, Dorothea Kronsteiner, Tim Hilgenfeld, Peter Rammelsberg, Franz Sebastian Schwindling

MARC

LEADER 00000caa a2200000 c 4500
001 177418933X
003 DE-627
005 20240414193458.0
007 cr uuu---uuuuu
008 211015s2021 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.jdent.2021.103744  |2 doi 
035 |a (DE-627)177418933X 
035 |a (DE-599)KXP177418933X 
035 |a (OCoLC)1341421974 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Horsch, Laura  |d 1991-  |e VerfasserIn  |0 (DE-588)1183802404  |0 (DE-627)1663340625  |4 aut 
245 1 0 |a Predictability and image quality of low-dose cone-beam computed tomography in computer-guided implantology  |b an experimental study  |c Laura Horsch, Christos Labis, Charlotte Theresa Trebing, Dorothea Kronsteiner, Tim Hilgenfeld, Peter Rammelsberg, Franz Sebastian Schwindling 
264 1 |c 9 July 2021 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 15.10.2021 
520 |a Objectives - To investigate the predictability and image quality of low-dose cone-beam computed tomography (LD-CBCT) in computer-guided implantology. - Methods - Pig cadaver mandibles were imaged using high-definition CBCT (HD-CBCT) and LD-CBCT (HD-CBCT: 85 kV, 6 mA, 14.2 s, 767 frames, 1184 mGycm2, voxel size 80 µm, effective dose 231 µSv; LD-CBCT: 85 kV, 10 mA, 2.1 s, 384 frames, 84 mGycm2, voxel size 160 µm, effective dose 16 µSv; Orthophos SL, Dentsply Sirona, Bensheim, Germany). Digital impressions were taken using intraoral scanning (IOS; Omnicam, Dentsply Sirona). Data of CBCT modalities and IOS were aligned. Forty-eight implants were planned virtually (24 implants per modality; Bone Level 4.1 × 10 mm; Straumann AG, Basel, Switzerland). Implants were inserted using templates by initial pilot drilling (“partially-guided implantation”). Implant positions were recorded using IOS. Geometric deviations between planned and definitive positions were assessed regarding implant apex, entry-point and angle. CBCT image quality was evaluated by raters twice on a four point scale. The results were exploratively compared (linear models, Mann-Whitney-U tests). - Results - Regarding implant apex, deviations were greater for LD-CBCT (mean 3.0±1.2 mm), as compared to HD-CBCT (mean 2.3±1.1 mm). For entry-point, no distinct difference was detected with a mean deviation of 1.4±0.9 mm in LD-CBCT, and 1.7±0.6 mm in HD-CBCT. Regarding angle, deviations were greater for LD-CBCT (mean 13.2±6.3°), as compared to HD-CBCT (mean 9.2±5.3°). The image quality of HD-CBCT provided to be better (mean 2.7±0.6) than that of LD-CBCT (mean 2.5±0.6). - Conclusions - Within the partially-guided approach, the results underline the potential of LD-CBCT alternatively to HD-CBCT for computer-guided implantology. Advantages of HD-CBCT need to be balanced against the higher radiation dose. 
650 4 |a CBCT 
650 4 |a Computer-guided surgery 
650 4 |a Dental implant 
650 4 |a Diagnostic accuracy 
650 4 |a Intraoral scanning 
650 4 |a Low-dose protocol 
700 1 |a Labis, Christos  |d 1991-  |e VerfasserIn  |0 (DE-588)1243274654  |0 (DE-627)1774189828  |4 aut 
700 1 |a Trebing, Charlotte Theresa  |e VerfasserIn  |0 (DE-588)1225686970  |0 (DE-627)1745534075  |4 aut 
700 1 |a Kronsteiner, Dorothea  |d 1991-  |e VerfasserIn  |0 (DE-588)1155734920  |0 (DE-627)1017938512  |0 (DE-576)501817794  |4 aut 
700 1 |a Hilgenfeld, Tim  |d 1986-  |e VerfasserIn  |0 (DE-588)1106261917  |0 (DE-627)862954398  |0 (DE-576)473950316  |4 aut 
700 1 |a Rammelsberg, Peter  |d 1959-  |e VerfasserIn  |0 (DE-588)122469836  |0 (DE-627)705920836  |0 (DE-576)293285640  |4 aut 
700 1 |a Schwindling, Franz Sebastian  |d 1986-  |e VerfasserIn  |0 (DE-588)1036843572  |0 (DE-627)751703613  |0 (DE-576)38697926X  |4 aut 
773 0 8 |i Enthalten in  |t Journal of dentistry  |d Amsterdam [u.a.] : Elsevier Science, 1972  |g 112(2021) vom: Sept., Artikel-ID 103744, Seite 1-7  |h Online-Ressource  |w (DE-627)320456757  |w (DE-600)2006760-4  |w (DE-576)09101770X  |x 1879-176X  |7 nnas  |a Predictability and image quality of low-dose cone-beam computed tomography in computer-guided implantology an experimental study 
773 1 8 |g volume:112  |g year:2021  |g month:09  |g elocationid:103744  |g pages:1-7  |g extent:7  |a Predictability and image quality of low-dose cone-beam computed tomography in computer-guided implantology an experimental study 
856 4 0 |u https://doi.org/10.1016/j.jdent.2021.103744  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0300571221001652  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20211015 
993 |a Article 
994 |a 2021 
998 |g 1036843572  |a Schwindling, Franz Sebastian  |m 1036843572:Schwindling, Franz Sebastian  |d 910000  |d 910800  |d 50000  |e 910000PS1036843572  |e 910800PS1036843572  |e 50000PS1036843572  |k 0/910000/  |k 1/910000/910800/  |k 0/50000/  |p 7  |y j 
998 |g 122469836  |a Rammelsberg, Peter  |m 122469836:Rammelsberg, Peter  |d 910000  |d 910800  |e 910000PR122469836  |e 910800PR122469836  |k 0/910000/  |k 1/910000/910800/  |p 6 
998 |g 1106261917  |a Hilgenfeld, Tim  |m 1106261917:Hilgenfeld, Tim  |d 910000  |d 911100  |d 50000  |e 910000PH1106261917  |e 911100PH1106261917  |e 50000PH1106261917  |k 0/910000/  |k 1/910000/911100/  |k 0/50000/  |p 5 
998 |g 1155734920  |a Kronsteiner, Dorothea  |m 1155734920:Kronsteiner, Dorothea  |d 50000  |e 50000PK1155734920  |k 0/50000/  |p 4 
998 |g 1225686970  |a Trebing, Charlotte Theresa  |m 1225686970:Trebing, Charlotte Theresa  |d 910000  |d 910800  |e 910000PT1225686970  |e 910800PT1225686970  |k 0/910000/  |k 1/910000/910800/  |p 3 
998 |g 1243274654  |a Labis, Christos  |m 1243274654:Labis, Christos  |d 910000  |d 910800  |e 910000PL1243274654  |e 910800PL1243274654  |k 0/910000/  |k 1/910000/910800/  |p 2 
998 |g 1183802404  |a Horsch, Laura  |m 1183802404:Horsch, Laura  |d 910000  |d 910800  |e 910000PH1183802404  |e 910800PH1183802404  |k 0/910000/  |k 1/910000/910800/  |p 1  |x j 
999 |a KXP-PPN177418933X  |e 3990322028 
BIB |a Y 
SER |a journal 
JSO |a {"recId":"177418933X","id":{"eki":["177418933X"],"doi":["10.1016/j.jdent.2021.103744"]},"name":{"displayForm":["Laura Horsch, Christos Labis, Charlotte Theresa Trebing, Dorothea Kronsteiner, Tim Hilgenfeld, Peter Rammelsberg, Franz Sebastian Schwindling"]},"person":[{"family":"Horsch","display":"Horsch, Laura","roleDisplay":"VerfasserIn","given":"Laura","role":"aut"},{"role":"aut","given":"Christos","roleDisplay":"VerfasserIn","display":"Labis, Christos","family":"Labis"},{"family":"Trebing","roleDisplay":"VerfasserIn","given":"Charlotte Theresa","display":"Trebing, Charlotte Theresa","role":"aut"},{"family":"Kronsteiner","display":"Kronsteiner, Dorothea","roleDisplay":"VerfasserIn","given":"Dorothea","role":"aut"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Hilgenfeld, Tim","given":"Tim","family":"Hilgenfeld"},{"given":"Peter","roleDisplay":"VerfasserIn","display":"Rammelsberg, Peter","family":"Rammelsberg","role":"aut"},{"family":"Schwindling","roleDisplay":"VerfasserIn","display":"Schwindling, Franz Sebastian","given":"Franz Sebastian","role":"aut"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"title":[{"title_sort":"Predictability and image quality of low-dose cone-beam computed tomography in computer-guided implantology","title":"Predictability and image quality of low-dose cone-beam computed tomography in computer-guided implantology","subtitle":"an experimental study"}],"origin":[{"dateIssuedDisp":"9 July 2021","dateIssuedKey":"2021"}],"note":["Gesehen am 15.10.2021"],"relHost":[{"origin":[{"publisherPlace":"Amsterdam [u.a.]","dateIssuedDisp":"1972-","publisher":"Elsevier Science","dateIssuedKey":"1972"}],"pubHistory":["1.1972 -"],"id":{"zdb":["2006760-4"],"eki":["320456757"],"issn":["1879-176X"]},"recId":"320456757","disp":"Predictability and image quality of low-dose cone-beam computed tomography in computer-guided implantology an experimental studyJournal of dentistry","language":["eng"],"title":[{"title":"Journal of dentistry","title_sort":"Journal of dentistry"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"note":["Gesehen am 04.05.07"],"part":{"volume":"112","extent":"7","text":"112(2021) vom: Sept., Artikel-ID 103744, Seite 1-7","year":"2021","pages":"1-7"},"physDesc":[{"extent":"Online-Ressource"}]}],"physDesc":[{"extent":"7 S."}],"language":["eng"]} 
SRT |a HORSCHLAURPREDICTABI9202