Primary stability in hip revision arthroplasty: comparison of the stability of cementless fixed augments on a modular acetabular cage system with and without cranial straps

The goal of this study is to evaluate the primary stability of a cementless augment-and-modular-cage system with and without the addition of cranial straps in a standardized in vitro setting. As the surrogate parameter for the evaluation of primary stability, the measurement of relative motion betwe...

Full description

Saved in:
Bibliographic Details
Main Authors: Jaenisch, Max (Author) , Kohlhof, Hendrik (Author) , Wirtz, Dieter Christian (Author) , Schildberg, Frank Alexander (Author) , Beckmann, Nicholas A. (Author) , Kretzer, Jan Philippe (Author) , Schonhoff, Mareike (Author) , Jäger, Sebastian (Author)
Format: Article (Journal)
Language:English
Published: 4 September 2021
In: Journal of Clinical Medicine
Year: 2021, Volume: 10, Issue: 17, Pages: 1-13
ISSN:2077-0383
DOI:10.3390/jcm10174002
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.3390/jcm10174002
Verlag, lizenzpflichtig, Volltext: https://www.mdpi.com/2077-0383/10/17/4002
Get full text
Author Notes:Max Jaenisch, Hendrik Kohlhof, Dieter Christian Wirtz, Frank Alexander Schildberg, Nicholas A. Beckmann, Jan Philippe Kretzer, Mareike Schonhoff and Sebastian Jäger

MARC

LEADER 00000caa a2200000 c 4500
001 1774355337
003 DE-627
005 20230427033938.0
007 cr uuu---uuuuu
008 211018s2021 xx |||||o 00| ||eng c
024 7 |a 10.3390/jcm10174002  |2 doi 
035 |a (DE-627)1774355337 
035 |a (DE-599)KXP1774355337 
035 |a (OCoLC)1341421782 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Jaenisch, Max  |e VerfasserIn  |0 (DE-588)1205386130  |0 (DE-627)1691022624  |4 aut 
245 1 0 |a Primary stability in hip revision arthroplasty  |b comparison of the stability of cementless fixed augments on a modular acetabular cage system with and without cranial straps  |c Max Jaenisch, Hendrik Kohlhof, Dieter Christian Wirtz, Frank Alexander Schildberg, Nicholas A. Beckmann, Jan Philippe Kretzer, Mareike Schonhoff and Sebastian Jäger 
264 1 |c 4 September 2021 
300 |a 13 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 18.10.2021 
520 |a The goal of this study is to evaluate the primary stability of a cementless augment-and-modular-cage system with and without the addition of cranial straps in a standardized in vitro setting. As the surrogate parameter for the evaluation of primary stability, the measurement of relative motion between the implant components themselves and the bone will be used. Acetabular revision components with a trabecular titanium augment in combination with a large fourth-generation composite left hemipelvis were assembled. These constructs were divided into two groups with (S) and without cranial straps (nS). A total of 1000 cycles was applied at each of three load levels. Relative movements (RM) between the components were measured. Load levels display a significant effect on the amount of RM at all interfaces except between shell/augment. The group assignment appears to have an effect on RM due to significantly differing means at all interfaces. Between bone/shell RM increased as load increased. NS displayed significantly more RM than S. Between shell/augment RM remained constant as load increased. Between shell/cup S showed more RM than nS while both groups’ RM increased with load. We conclude a significant increase of primary stability between the shell and the bone through the addition of cranial straps. Relative motion between components (shell/cup) increases through the addition of cranial straps. A clinical impact of this finding is uncertain and requires further investigation. Finally, the cementless fixation of the augment against the rim-portion of the shell appears stable and compares favorably to prior investigation of different fixation techniques. 
650 4 |a arthroplasty 
650 4 |a augment 
650 4 |a cementless 
650 4 |a cranial strap 
650 4 |a hip 
650 4 |a modular 
650 4 |a revision 
700 1 |a Kohlhof, Hendrik  |e VerfasserIn  |4 aut 
700 1 |a Wirtz, Dieter Christian  |e VerfasserIn  |4 aut 
700 1 |a Schildberg, Frank Alexander  |e VerfasserIn  |4 aut 
700 1 |a Beckmann, Nicholas A.  |e VerfasserIn  |0 (DE-588)1011716305  |0 (DE-627)65931164X  |0 (DE-576)343558114  |4 aut 
700 1 |a Kretzer, Jan Philippe  |d 1978-  |e VerfasserIn  |0 (DE-588)136998348  |0 (DE-627)589003690  |0 (DE-576)301383103  |4 aut 
700 1 |a Schonhoff, Mareike  |e VerfasserIn  |0 (DE-588)120821747X  |0 (DE-627)1694427137  |4 aut 
700 1 |a Jäger, Sebastian  |d 1975-  |e VerfasserIn  |0 (DE-588)1059313731  |0 (DE-627)79828238X  |0 (DE-576)415306647  |4 aut 
773 0 8 |i Enthalten in  |t Journal of Clinical Medicine  |d Basel : MDPI, 2012  |g 10(2021), 17, Artikel-ID 4002, Seite 1-13  |h Online-Ressource  |w (DE-627)718632478  |w (DE-600)2662592-1  |w (DE-576)365782718  |x 2077-0383  |7 nnas  |a Primary stability in hip revision arthroplasty comparison of the stability of cementless fixed augments on a modular acetabular cage system with and without cranial straps 
773 1 8 |g volume:10  |g year:2021  |g number:17  |g elocationid:4002  |g pages:1-13  |g extent:13  |a Primary stability in hip revision arthroplasty comparison of the stability of cementless fixed augments on a modular acetabular cage system with and without cranial straps 
856 4 0 |u https://doi.org/10.3390/jcm10174002  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.mdpi.com/2077-0383/10/17/4002  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20211018 
993 |a Article 
994 |a 2021 
998 |g 1059313731  |a Jäger, Sebastian  |m 1059313731:Jäger, Sebastian  |d 910000  |d 911460  |e 910000PJ1059313731  |e 911460PJ1059313731  |k 0/910000/  |k 1/910000/911460/  |p 8  |y j 
998 |g 120821747X  |a Schonhoff, Mareike  |m 120821747X:Schonhoff, Mareike  |d 910000  |d 911460  |e 910000PS120821747X  |e 911460PS120821747X  |k 0/910000/  |k 1/910000/911460/  |p 7 
998 |g 136998348  |a Kretzer, Jan Philippe  |m 136998348:Kretzer, Jan Philippe  |d 910000  |d 911460  |d 50000  |e 910000PK136998348  |e 911460PK136998348  |e 50000PK136998348  |k 0/910000/  |k 1/910000/911460/  |k 0/50000/  |p 6 
998 |g 1011716305  |a Beckmann, Nicholas A.  |m 1011716305:Beckmann, Nicholas A.  |d 910000  |d 911460  |d 50000  |e 910000PB1011716305  |e 911460PB1011716305  |e 50000PB1011716305  |k 0/910000/  |k 1/910000/911460/  |k 0/50000/  |p 5 
999 |a KXP-PPN1774355337  |e 3990973177 
BIB |a Y 
SER |a journal 
JSO |a {"type":{"media":"Online-Ressource","bibl":"article-journal"},"origin":[{"dateIssuedDisp":"4 September 2021","dateIssuedKey":"2021"}],"recId":"1774355337","relHost":[{"id":{"issn":["2077-0383"],"zdb":["2662592-1"],"eki":["718632478"]},"physDesc":[{"extent":"Online-Ressource"}],"disp":"Primary stability in hip revision arthroplasty comparison of the stability of cementless fixed augments on a modular acetabular cage system with and without cranial strapsJournal of Clinical Medicine","note":["Gesehen am 12.06.20"],"origin":[{"dateIssuedDisp":"2012-","publisher":"MDPI","dateIssuedKey":"2012","publisherPlace":"Basel"}],"recId":"718632478","type":{"bibl":"periodical","media":"Online-Ressource"},"title":[{"title_sort":"Journal of Clinical Medicine","title":"Journal of Clinical Medicine","subtitle":"open access journal"}],"part":{"issue":"17","pages":"1-13","extent":"13","volume":"10","text":"10(2021), 17, Artikel-ID 4002, Seite 1-13","year":"2021"},"language":["eng"],"pubHistory":["1.2012 -"]}],"note":["Gesehen am 18.10.2021"],"id":{"eki":["1774355337"],"doi":["10.3390/jcm10174002"]},"physDesc":[{"extent":"13 S."}],"name":{"displayForm":["Max Jaenisch, Hendrik Kohlhof, Dieter Christian Wirtz, Frank Alexander Schildberg, Nicholas A. Beckmann, Jan Philippe Kretzer, Mareike Schonhoff and Sebastian Jäger"]},"person":[{"family":"Jaenisch","role":"aut","given":"Max","display":"Jaenisch, Max"},{"family":"Kohlhof","display":"Kohlhof, Hendrik","role":"aut","given":"Hendrik"},{"family":"Wirtz","display":"Wirtz, Dieter Christian","given":"Dieter Christian","role":"aut"},{"display":"Schildberg, Frank Alexander","role":"aut","given":"Frank Alexander","family":"Schildberg"},{"role":"aut","given":"Nicholas A.","display":"Beckmann, Nicholas A.","family":"Beckmann"},{"family":"Kretzer","display":"Kretzer, Jan Philippe","role":"aut","given":"Jan Philippe"},{"display":"Schonhoff, Mareike","given":"Mareike","role":"aut","family":"Schonhoff"},{"display":"Jäger, Sebastian","given":"Sebastian","role":"aut","family":"Jäger"}],"language":["eng"],"title":[{"title_sort":"Primary stability in hip revision arthroplasty","title":"Primary stability in hip revision arthroplasty","subtitle":"comparison of the stability of cementless fixed augments on a modular acetabular cage system with and without cranial straps"}]} 
SRT |a JAENISCHMAPRIMARYSTA4202