Primary stability in hip revision arthroplasty: comparison of the stability of cementless fixed augments on a modular acetabular cage system with and without cranial straps
The goal of this study is to evaluate the primary stability of a cementless augment-and-modular-cage system with and without the addition of cranial straps in a standardized in vitro setting. As the surrogate parameter for the evaluation of primary stability, the measurement of relative motion betwe...
Saved in:
| Main Authors: | , , , , , , , |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
4 September 2021
|
| In: |
Journal of Clinical Medicine
Year: 2021, Volume: 10, Issue: 17, Pages: 1-13 |
| ISSN: | 2077-0383 |
| DOI: | 10.3390/jcm10174002 |
| Online Access: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.3390/jcm10174002 Verlag, lizenzpflichtig, Volltext: https://www.mdpi.com/2077-0383/10/17/4002 |
| Author Notes: | Max Jaenisch, Hendrik Kohlhof, Dieter Christian Wirtz, Frank Alexander Schildberg, Nicholas A. Beckmann, Jan Philippe Kretzer, Mareike Schonhoff and Sebastian Jäger |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1774355337 | ||
| 003 | DE-627 | ||
| 005 | 20230427033938.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 211018s2021 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.3390/jcm10174002 |2 doi | |
| 035 | |a (DE-627)1774355337 | ||
| 035 | |a (DE-599)KXP1774355337 | ||
| 035 | |a (OCoLC)1341421782 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Jaenisch, Max |e VerfasserIn |0 (DE-588)1205386130 |0 (DE-627)1691022624 |4 aut | |
| 245 | 1 | 0 | |a Primary stability in hip revision arthroplasty |b comparison of the stability of cementless fixed augments on a modular acetabular cage system with and without cranial straps |c Max Jaenisch, Hendrik Kohlhof, Dieter Christian Wirtz, Frank Alexander Schildberg, Nicholas A. Beckmann, Jan Philippe Kretzer, Mareike Schonhoff and Sebastian Jäger |
| 264 | 1 | |c 4 September 2021 | |
| 300 | |a 13 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 18.10.2021 | ||
| 520 | |a The goal of this study is to evaluate the primary stability of a cementless augment-and-modular-cage system with and without the addition of cranial straps in a standardized in vitro setting. As the surrogate parameter for the evaluation of primary stability, the measurement of relative motion between the implant components themselves and the bone will be used. Acetabular revision components with a trabecular titanium augment in combination with a large fourth-generation composite left hemipelvis were assembled. These constructs were divided into two groups with (S) and without cranial straps (nS). A total of 1000 cycles was applied at each of three load levels. Relative movements (RM) between the components were measured. Load levels display a significant effect on the amount of RM at all interfaces except between shell/augment. The group assignment appears to have an effect on RM due to significantly differing means at all interfaces. Between bone/shell RM increased as load increased. NS displayed significantly more RM than S. Between shell/augment RM remained constant as load increased. Between shell/cup S showed more RM than nS while both groups’ RM increased with load. We conclude a significant increase of primary stability between the shell and the bone through the addition of cranial straps. Relative motion between components (shell/cup) increases through the addition of cranial straps. A clinical impact of this finding is uncertain and requires further investigation. Finally, the cementless fixation of the augment against the rim-portion of the shell appears stable and compares favorably to prior investigation of different fixation techniques. | ||
| 650 | 4 | |a arthroplasty | |
| 650 | 4 | |a augment | |
| 650 | 4 | |a cementless | |
| 650 | 4 | |a cranial strap | |
| 650 | 4 | |a hip | |
| 650 | 4 | |a modular | |
| 650 | 4 | |a revision | |
| 700 | 1 | |a Kohlhof, Hendrik |e VerfasserIn |4 aut | |
| 700 | 1 | |a Wirtz, Dieter Christian |e VerfasserIn |4 aut | |
| 700 | 1 | |a Schildberg, Frank Alexander |e VerfasserIn |4 aut | |
| 700 | 1 | |a Beckmann, Nicholas A. |e VerfasserIn |0 (DE-588)1011716305 |0 (DE-627)65931164X |0 (DE-576)343558114 |4 aut | |
| 700 | 1 | |a Kretzer, Jan Philippe |d 1978- |e VerfasserIn |0 (DE-588)136998348 |0 (DE-627)589003690 |0 (DE-576)301383103 |4 aut | |
| 700 | 1 | |a Schonhoff, Mareike |e VerfasserIn |0 (DE-588)120821747X |0 (DE-627)1694427137 |4 aut | |
| 700 | 1 | |a Jäger, Sebastian |d 1975- |e VerfasserIn |0 (DE-588)1059313731 |0 (DE-627)79828238X |0 (DE-576)415306647 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Journal of Clinical Medicine |d Basel : MDPI, 2012 |g 10(2021), 17, Artikel-ID 4002, Seite 1-13 |h Online-Ressource |w (DE-627)718632478 |w (DE-600)2662592-1 |w (DE-576)365782718 |x 2077-0383 |7 nnas |a Primary stability in hip revision arthroplasty comparison of the stability of cementless fixed augments on a modular acetabular cage system with and without cranial straps |
| 773 | 1 | 8 | |g volume:10 |g year:2021 |g number:17 |g elocationid:4002 |g pages:1-13 |g extent:13 |a Primary stability in hip revision arthroplasty comparison of the stability of cementless fixed augments on a modular acetabular cage system with and without cranial straps |
| 856 | 4 | 0 | |u https://doi.org/10.3390/jcm10174002 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://www.mdpi.com/2077-0383/10/17/4002 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20211018 | ||
| 993 | |a Article | ||
| 994 | |a 2021 | ||
| 998 | |g 1059313731 |a Jäger, Sebastian |m 1059313731:Jäger, Sebastian |d 910000 |d 911460 |e 910000PJ1059313731 |e 911460PJ1059313731 |k 0/910000/ |k 1/910000/911460/ |p 8 |y j | ||
| 998 | |g 120821747X |a Schonhoff, Mareike |m 120821747X:Schonhoff, Mareike |d 910000 |d 911460 |e 910000PS120821747X |e 911460PS120821747X |k 0/910000/ |k 1/910000/911460/ |p 7 | ||
| 998 | |g 136998348 |a Kretzer, Jan Philippe |m 136998348:Kretzer, Jan Philippe |d 910000 |d 911460 |d 50000 |e 910000PK136998348 |e 911460PK136998348 |e 50000PK136998348 |k 0/910000/ |k 1/910000/911460/ |k 0/50000/ |p 6 | ||
| 998 | |g 1011716305 |a Beckmann, Nicholas A. |m 1011716305:Beckmann, Nicholas A. |d 910000 |d 911460 |d 50000 |e 910000PB1011716305 |e 911460PB1011716305 |e 50000PB1011716305 |k 0/910000/ |k 1/910000/911460/ |k 0/50000/ |p 5 | ||
| 999 | |a KXP-PPN1774355337 |e 3990973177 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"type":{"media":"Online-Ressource","bibl":"article-journal"},"origin":[{"dateIssuedDisp":"4 September 2021","dateIssuedKey":"2021"}],"recId":"1774355337","relHost":[{"id":{"issn":["2077-0383"],"zdb":["2662592-1"],"eki":["718632478"]},"physDesc":[{"extent":"Online-Ressource"}],"disp":"Primary stability in hip revision arthroplasty comparison of the stability of cementless fixed augments on a modular acetabular cage system with and without cranial strapsJournal of Clinical Medicine","note":["Gesehen am 12.06.20"],"origin":[{"dateIssuedDisp":"2012-","publisher":"MDPI","dateIssuedKey":"2012","publisherPlace":"Basel"}],"recId":"718632478","type":{"bibl":"periodical","media":"Online-Ressource"},"title":[{"title_sort":"Journal of Clinical Medicine","title":"Journal of Clinical Medicine","subtitle":"open access journal"}],"part":{"issue":"17","pages":"1-13","extent":"13","volume":"10","text":"10(2021), 17, Artikel-ID 4002, Seite 1-13","year":"2021"},"language":["eng"],"pubHistory":["1.2012 -"]}],"note":["Gesehen am 18.10.2021"],"id":{"eki":["1774355337"],"doi":["10.3390/jcm10174002"]},"physDesc":[{"extent":"13 S."}],"name":{"displayForm":["Max Jaenisch, Hendrik Kohlhof, Dieter Christian Wirtz, Frank Alexander Schildberg, Nicholas A. Beckmann, Jan Philippe Kretzer, Mareike Schonhoff and Sebastian Jäger"]},"person":[{"family":"Jaenisch","role":"aut","given":"Max","display":"Jaenisch, Max"},{"family":"Kohlhof","display":"Kohlhof, Hendrik","role":"aut","given":"Hendrik"},{"family":"Wirtz","display":"Wirtz, Dieter Christian","given":"Dieter Christian","role":"aut"},{"display":"Schildberg, Frank Alexander","role":"aut","given":"Frank Alexander","family":"Schildberg"},{"role":"aut","given":"Nicholas A.","display":"Beckmann, Nicholas A.","family":"Beckmann"},{"family":"Kretzer","display":"Kretzer, Jan Philippe","role":"aut","given":"Jan Philippe"},{"display":"Schonhoff, Mareike","given":"Mareike","role":"aut","family":"Schonhoff"},{"display":"Jäger, Sebastian","given":"Sebastian","role":"aut","family":"Jäger"}],"language":["eng"],"title":[{"title_sort":"Primary stability in hip revision arthroplasty","title":"Primary stability in hip revision arthroplasty","subtitle":"comparison of the stability of cementless fixed augments on a modular acetabular cage system with and without cranial straps"}]} | ||
| SRT | |a JAENISCHMAPRIMARYSTA4202 | ||