Iodine concentration and tissue attenuation in dual-energy contrast-enhanced CT as a potential quantitative parameter in early detection of local pancreatic carcinoma recurrence after surgical resection

Purpose - Due to the difficult differentiation from non-specific postoperative soft tissue formation (PSF), early diagnosis of pancreatic carcinoma recurrence remains challenging. Thus, we investigated the diagnostic potential of dual-energy (DE) contrast-enhanced CT. - Method - After potentially cu...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Mathy, René Michael (VerfasserIn) , Fritz, Franziska (VerfasserIn) , Mayer, Philipp (VerfasserIn) , Klauß, Miriam (VerfasserIn) , Grenacher, Lars (VerfasserIn) , Stiller, Wolfram (VerfasserIn) , Kauczor, Hans-Ulrich (VerfasserIn) , Skornitzke, Stephan (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: October 2021
In: European journal of radiology
Year: 2021, Jahrgang: 143, Pages: 1-7
ISSN:1872-7727
DOI:10.1016/j.ejrad.2021.109944
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.ejrad.2021.109944
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0720048X21004253
Volltext
Verfasserangaben:René Michael Mathy, Franziska Fritz, Philipp Mayer, Miriam Klauss, Lars Grenacher, Wolfram Stiller, Hans-Ulrich Kauczor, Stephan Skornitzke

MARC

LEADER 00000caa a2200000 c 4500
001 1774607034
003 DE-627
005 20240414193508.0
007 cr uuu---uuuuu
008 211020s2021 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.ejrad.2021.109944  |2 doi 
035 |a (DE-627)1774607034 
035 |a (DE-599)KXP1774607034 
035 |a (OCoLC)1341422054 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Mathy, René Michael  |e VerfasserIn  |0 (DE-588)1225699282  |0 (DE-627)1745562877  |4 aut 
245 1 0 |a Iodine concentration and tissue attenuation in dual-energy contrast-enhanced CT as a potential quantitative parameter in early detection of local pancreatic carcinoma recurrence after surgical resection  |c René Michael Mathy, Franziska Fritz, Philipp Mayer, Miriam Klauss, Lars Grenacher, Wolfram Stiller, Hans-Ulrich Kauczor, Stephan Skornitzke 
264 1 |c October 2021 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 20.10.2021 
520 |a Purpose - Due to the difficult differentiation from non-specific postoperative soft tissue formation (PSF), early diagnosis of pancreatic carcinoma recurrence remains challenging. Thus, we investigated the diagnostic potential of dual-energy (DE) contrast-enhanced CT. - Method - After potentially curative pancreatic carcinoma resection, 31 consecutive patients with PSF were examined via DE perfusion CT, acquiring 34 images (80 kVp/140 kVp) every 1.5 s, as the initial purpose of this study was evaluating CT-Perfusion. Corresponding time points of arterial, pancreatic, and early venous phase were calculated from bolus trigger times in prior conventional CT. Iodine and 120 kVp-equivalent images were calculated. Regions of interest were placed in each soft tissue formation. Diagnosis of local recurrence was confirmed by regular follow-up or histopathology. - Results - Final diagnosis was local recurrence in 17 patients and non-specific PSF in 14 patients. Iodine concentrations in early venous phase were significantly higher in recurrent carcinoma than in non-specific PSF (1.47 mg/ml vs. 0.96 mg/ml, p = 0.007). In earlier contrast phases iodine concentrations tended to be higher, but not significantly. CT numbers in recurrent carcinoma in 120 kVp-equivalent images in venous phase were significantly higher, too (74HU vs 47HU, p = 0.002). ROC-curve analysis for iodine concentrations in early venous phase suggests a cut-off value of ≥ 1.55 mg/ml for local recurrence (AUC = 0.78, specificity = 1.0, sensitivity = 0.53) and for CT numbers in 120kVp-equivalent images a cut-off value of ≥ 57HU (AUC = 0.82, specificity = 0.82, sensitivity = 0.71). - Conclusion - In difficult cases, measuring iodine concentrations or CT numbers in PSF in (early) venous phase DECT could be a valuable additional parameter for differentiating local recurrence from non-specific PSF. 
650 4 |a Computed tomography 
650 4 |a Dual-energy CT 
650 4 |a Iodine concentration 
650 4 |a Pancreatic carcinoma recurrence 
650 4 |a Postoperative soft tissue formation 
700 1 |a Fritz, Franziska  |d 1986-  |e VerfasserIn  |0 (DE-588)1041966393  |0 (DE-627)768050987  |0 (DE-576)393612600  |4 aut 
700 1 |a Mayer, Philipp  |d 1985-  |e VerfasserIn  |0 (DE-588)1066605440  |0 (DE-627)817714758  |0 (DE-576)426052250  |4 aut 
700 1 |a Klauß, Miriam  |d 1978-  |e VerfasserIn  |0 (DE-588)130870552  |0 (DE-627)506783839  |0 (DE-576)29838728X  |4 aut 
700 1 |a Grenacher, Lars  |d 1967-  |e VerfasserIn  |0 (DE-588)115424598  |0 (DE-627)691308977  |0 (DE-576)289876761  |4 aut 
700 1 |a Stiller, Wolfram  |d 1976-  |e VerfasserIn  |0 (DE-588)105822672X  |0 (DE-627)796627495  |0 (DE-576)414249496  |4 aut 
700 1 |a Kauczor, Hans-Ulrich  |d 1962-  |e VerfasserIn  |0 (DE-588)139267123  |0 (DE-627)70327113X  |0 (DE-576)310955327  |4 aut 
700 1 |a Skornitzke, Stephan  |d 1987-  |e VerfasserIn  |0 (DE-588)1110072589  |0 (DE-627)864783523  |0 (DE-576)475718267  |4 aut 
773 0 8 |i Enthalten in  |t European journal of radiology  |d Amsterdam [u.a.] : Elsevier Science, 1990  |g 143(2021) vom: Okt., Artikel-ID 109944, Seite 1-7  |h Online-Ressource  |w (DE-627)32044483X  |w (DE-600)2005350-2  |w (DE-576)099718138  |x 1872-7727  |7 nnas  |a Iodine concentration and tissue attenuation in dual-energy contrast-enhanced CT as a potential quantitative parameter in early detection of local pancreatic carcinoma recurrence after surgical resection 
773 1 8 |g volume:143  |g year:2021  |g month:10  |g elocationid:109944  |g pages:1-7  |g extent:7  |a Iodine concentration and tissue attenuation in dual-energy contrast-enhanced CT as a potential quantitative parameter in early detection of local pancreatic carcinoma recurrence after surgical resection 
856 4 0 |u https://doi.org/10.1016/j.ejrad.2021.109944  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0720048X21004253  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20211020 
993 |a Article 
994 |a 2021 
998 |g 1110072589  |a Skornitzke, Stephan  |m 1110072589:Skornitzke, Stephan  |d 910000  |d 911400  |e 910000PS1110072589  |e 911400PS1110072589  |k 0/910000/  |k 1/910000/911400/  |p 8  |y j 
998 |g 139267123  |a Kauczor, Hans-Ulrich  |m 139267123:Kauczor, Hans-Ulrich  |d 910000  |d 911400  |e 910000PK139267123  |e 911400PK139267123  |k 0/910000/  |k 1/910000/911400/  |p 7 
998 |g 105822672X  |a Stiller, Wolfram  |m 105822672X:Stiller, Wolfram  |d 910000  |d 911400  |d 50000  |e 910000PS105822672X  |e 911400PS105822672X  |e 50000PS105822672X  |k 0/910000/  |k 1/910000/911400/  |k 0/50000/  |p 6 
998 |g 115424598  |a Grenacher, Lars  |m 115424598:Grenacher, Lars  |d 50000  |e 50000PG115424598  |k 0/50000/  |p 5 
998 |g 130870552  |a Klauß, Miriam  |m 130870552:Klauß, Miriam  |d 910000  |d 911400  |d 50000  |e 910000PK130870552  |e 911400PK130870552  |e 50000PK130870552  |k 0/910000/  |k 1/910000/911400/  |k 0/50000/  |p 4 
998 |g 1066605440  |a Mayer, Philipp  |m 1066605440:Mayer, Philipp  |d 910000  |d 911400  |e 910000PM1066605440  |e 911400PM1066605440  |k 0/910000/  |k 1/910000/911400/  |p 3 
998 |g 1041966393  |a Fritz, Franziska  |m 1041966393:Fritz, Franziska  |d 50000  |e 50000PF1041966393  |k 0/50000/  |p 2 
998 |g 1225699282  |a Mathy, René Michael  |m 1225699282:Mathy, René Michael  |d 910000  |d 911400  |e 910000PM1225699282  |e 911400PM1225699282  |k 0/910000/  |k 1/910000/911400/  |p 1  |x j 
999 |a KXP-PPN1774607034  |e 3991737868 
BIB |a Y 
SER |a journal 
JSO |a {"id":{"eki":["1774607034"],"doi":["10.1016/j.ejrad.2021.109944"]},"name":{"displayForm":["René Michael Mathy, Franziska Fritz, Philipp Mayer, Miriam Klauss, Lars Grenacher, Wolfram Stiller, Hans-Ulrich Kauczor, Stephan Skornitzke"]},"physDesc":[{"extent":"7 S."}],"recId":"1774607034","note":["Gesehen am 20.10.2021"],"language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"title":[{"title":"Iodine concentration and tissue attenuation in dual-energy contrast-enhanced CT as a potential quantitative parameter in early detection of local pancreatic carcinoma recurrence after surgical resection","title_sort":"Iodine concentration and tissue attenuation in dual-energy contrast-enhanced CT as a potential quantitative parameter in early detection of local pancreatic carcinoma recurrence after surgical resection"}],"person":[{"display":"Mathy, René Michael","role":"aut","given":"René Michael","family":"Mathy"},{"display":"Fritz, Franziska","family":"Fritz","role":"aut","given":"Franziska"},{"display":"Mayer, Philipp","family":"Mayer","given":"Philipp","role":"aut"},{"family":"Klauß","role":"aut","given":"Miriam","display":"Klauß, Miriam"},{"role":"aut","given":"Lars","family":"Grenacher","display":"Grenacher, Lars"},{"given":"Wolfram","role":"aut","family":"Stiller","display":"Stiller, Wolfram"},{"family":"Kauczor","given":"Hans-Ulrich","role":"aut","display":"Kauczor, Hans-Ulrich"},{"family":"Skornitzke","given":"Stephan","role":"aut","display":"Skornitzke, Stephan"}],"relHost":[{"pubHistory":["Nachgewiesen 10.1990 -"],"titleAlt":[{"title":"EJR"}],"part":{"pages":"1-7","year":"2021","text":"143(2021) vom: Okt., Artikel-ID 109944, Seite 1-7","volume":"143","extent":"7"},"id":{"zdb":["2005350-2"],"eki":["32044483X"],"issn":["1872-7727"]},"recId":"32044483X","physDesc":[{"extent":"Online-Ressource"}],"disp":"Iodine concentration and tissue attenuation in dual-energy contrast-enhanced CT as a potential quantitative parameter in early detection of local pancreatic carcinoma recurrence after surgical resectionEuropean journal of radiology","origin":[{"publisher":"Elsevier Science","dateIssuedDisp":"1990-","dateIssuedKey":"1990","publisherPlace":"Amsterdam [u.a.]"}],"title":[{"title_sort":"European journal of radiology","title":"European journal of radiology","subtitle":"EJR"}],"note":["Gesehen am 05.02.20"],"language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"}}],"origin":[{"dateIssuedDisp":"October 2021","dateIssuedKey":"2021"}]} 
SRT |a MATHYRENEMIODINECONC2021