Body mass index-adapted prospective coronary computed tomography angiography: determining the lowest limit for diagnostic purposes

Purpose - To investigate the value of 4 different protocols for prospectively triggered 256-slice coronary computed tomography angiography (coronary CTA). - Methods - Two hundred and ten patients underwent prospectively triggered coronary CTA for suspected or known coronary artery disease (CAD). Pat...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Hosch, Waldemar P. (VerfasserIn) , Hofmann, Nina (VerfasserIn) , Mueller, Dirk (VerfasserIn) , Iwan, Johannes (VerfasserIn) , Gitsioudis, Gitsios (VerfasserIn) , Siebert, Stefan (VerfasserIn) , Giannitsis, Evangelos (VerfasserIn) , Kauczor, Hans-Ulrich (VerfasserIn) , Katus, Hugo (VerfasserIn) , Korosoglou, Grigorios (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 14 January 2013
In: European journal of radiology
Year: 2013, Jahrgang: 82, Heft: 5, Pages: e232-e239
ISSN:1872-7727
DOI:10.1016/j.ejrad.2012.12.013
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.ejrad.2012.12.013
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0720048X12006419
Volltext
Verfasserangaben:Waldemar Hosch, Nina P. Hofmann, Dirk Mueller, Johannes Iwan, Gitsios Gitsioudis, Stefan Siebert, Evangelos Giannitsis, Hans U. Kauczor, Hugo A. Katus, Grigorios Korosoglou

MARC

LEADER 00000caa a2200000 c 4500
001 1775489582
003 DE-627
005 20230426125408.0
007 cr uuu---uuuuu
008 211026s2013 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.ejrad.2012.12.013  |2 doi 
035 |a (DE-627)1775489582 
035 |a (DE-599)KXP1775489582 
035 |a (OCoLC)1341422310 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Hosch, Waldemar P.  |d 1969-  |e VerfasserIn  |0 (DE-588)11585696X  |0 (DE-627)691639205  |0 (DE-576)290116562  |4 aut 
245 1 0 |a Body mass index-adapted prospective coronary computed tomography angiography  |b determining the lowest limit for diagnostic purposes  |c Waldemar Hosch, Nina P. Hofmann, Dirk Mueller, Johannes Iwan, Gitsios Gitsioudis, Stefan Siebert, Evangelos Giannitsis, Hans U. Kauczor, Hugo A. Katus, Grigorios Korosoglou 
264 1 |c 14 January 2013 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 26.10.2021 
520 |a Purpose - To investigate the value of 4 different protocols for prospectively triggered 256-slice coronary computed tomography angiography (coronary CTA). - Methods - Two hundred and ten patients underwent prospectively triggered coronary CTA for suspected or known coronary artery disease (CAD). Patients with heart rate >75bps before the scan despite ß-blocker administration and with arrhythmia were excluded. From January to September 2010, 60 patients underwent coronary CTA using a non-tailored protocol (120kV; 200mAs) and served as our ‘control’ group. From September 2010 to April 2012, based on the body mass index (BMI) of the examined patients (BMI subgroups of <25; 25-28; 28-30, and ≥30kg/m2) current tube voltage and tube current were: (1) slightly, (2) moderately or (3) strongly reduced, resulting into the 3 following BMI-adapted acquisition groups: (1) a ‘standard’ (100/120kV; 100-200mAs; n=50), 2) a ‘low dose’ (100/120kV; 75-150mAs; n=50), and 3) an ‘ultra-low dose’ (100/120kV; 50-100mAs; n=50) protocol. - Results - Patients examined using the non-tailored protocol exhibited the highest radiation exposure (3.2±0.4mSv), followed by the standard (1.6±0.7mSv), low-dose (1.2±0.6mSv) and ultra-low dose protocol (0.7±0.3mSv) (radiation savings of 50%, 63% and 78% respectively). Overall image quality was similar with standard dose (1.9±0.6) and low-dose (2.0±0.5) compared to the non-tailored group (1.9±0.5) (p=NS for all). In the ultra-low dose group however, image quality was significant reduced (2.7±0.6), p<0.05 versus all other groups). - Conclusion - Using BMI-adapted low dose acquisitions image quality can be maintained with simultaneous radiation savings of ∼65% (dose of ∼1mSv). This appears to be the lower limit for diagnostic coronary CTA, whereas ultra-low dose acquisitions result in significant image degradation. 
650 4 |a 256-Slice computed tomography angiography 
650 4 |a Image quality 
650 4 |a Prospective ECG-triggering 
650 4 |a Radiation exposure 
650 4 |a Ultra-low dose coronary CTA 
700 1 |a Hofmann, Nina  |d 1984-  |e VerfasserIn  |0 (DE-588)1019370645  |0 (DE-627)685028623  |0 (DE-576)357885821  |4 aut 
700 1 |a Mueller, Dirk  |e VerfasserIn  |4 aut 
700 1 |a Iwan, Johannes  |e VerfasserIn  |4 aut 
700 1 |a Gitsioudis, Gitsios  |d 1981-  |e VerfasserIn  |0 (DE-588)138256209  |0 (DE-627)600669149  |0 (DE-576)30648174X  |4 aut 
700 1 |a Siebert, Stefan  |d 1973-  |e VerfasserIn  |0 (DE-588)139196080  |0 (DE-627)60903362X  |0 (DE-576)310135303  |4 aut 
700 1 |a Giannitsis, Evangelos  |e VerfasserIn  |0 (DE-588)113336241  |0 (DE-627)577184091  |0 (DE-576)289759579  |4 aut 
700 1 |a Kauczor, Hans-Ulrich  |d 1962-  |e VerfasserIn  |0 (DE-588)139267123  |0 (DE-627)70327113X  |0 (DE-576)310955327  |4 aut 
700 1 |a Katus, Hugo  |d 1951-  |e VerfasserIn  |0 (DE-588)108916618  |0 (DE-627)577155040  |0 (DE-576)289625076  |4 aut 
700 1 |a Korosoglou, Grigorios  |d 1976-  |e VerfasserIn  |0 (DE-588)12854225X  |0 (DE-627)374709025  |0 (DE-576)297204912  |4 aut 
773 0 8 |i Enthalten in  |t European journal of radiology  |d Amsterdam [u.a.] : Elsevier Science, 1990  |g 82(2013), 5, Seite e232-e239  |h Online-Ressource  |w (DE-627)32044483X  |w (DE-600)2005350-2  |w (DE-576)099718138  |x 1872-7727  |7 nnas  |a Body mass index-adapted prospective coronary computed tomography angiography determining the lowest limit for diagnostic purposes 
773 1 8 |g volume:82  |g year:2013  |g number:5  |g pages:e232-e239  |g extent:8  |a Body mass index-adapted prospective coronary computed tomography angiography determining the lowest limit for diagnostic purposes 
856 4 0 |u https://doi.org/10.1016/j.ejrad.2012.12.013  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0720048X12006419  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20211026 
993 |a Article 
994 |a 2013 
998 |g 12854225X  |a Korosoglou, Grigorios  |m 12854225X:Korosoglou, Grigorios  |d 910000  |d 910100  |e 910000PK12854225X  |e 910100PK12854225X  |k 0/910000/  |k 1/910000/910100/  |p 10 
998 |g 108916618  |a Katus, Hugo  |m 108916618:Katus, Hugo  |d 910000  |d 910100  |e 910000PK108916618  |e 910100PK108916618  |k 0/910000/  |k 1/910000/910100/  |p 9 
998 |g 139267123  |a Kauczor, Hans-Ulrich  |m 139267123:Kauczor, Hans-Ulrich  |d 910000  |d 911400  |e 910000PK139267123  |e 911400PK139267123  |k 0/910000/  |k 1/910000/911400/  |p 8  |y j 
998 |g 113336241  |a Giannitsis, Evangelos  |m 113336241:Giannitsis, Evangelos  |d 910000  |d 910100  |e 910000PG113336241  |e 910100PG113336241  |k 0/910000/  |k 1/910000/910100/  |p 7 
998 |g 139196080  |a Siebert, Stefan  |m 139196080:Siebert, Stefan  |d 910000  |d 911400  |e 910000PS139196080  |e 911400PS139196080  |k 0/910000/  |k 1/910000/911400/  |p 6 
998 |g 138256209  |a Gitsioudis, Gitsios  |m 138256209:Gitsioudis, Gitsios  |d 910000  |d 910100  |e 910000PG138256209  |e 910100PG138256209  |k 0/910000/  |k 1/910000/910100/  |p 5 
998 |g 1019370645  |a Hofmann, Nina  |m 1019370645:Hofmann, Nina  |p 2 
998 |g 11585696X  |a Hosch, Waldemar P.  |m 11585696X:Hosch, Waldemar P.  |d 50000  |e 50000PH11585696X  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN1775489582  |e 3996506902 
BIB |a Y 
SER |a journal 
JSO |a {"recId":"1775489582","relHost":[{"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"Body mass index-adapted prospective coronary computed tomography angiography determining the lowest limit for diagnostic purposesEuropean journal of radiology","title":[{"subtitle":"EJR","title_sort":"European journal of radiology","title":"European journal of radiology"}],"origin":[{"publisher":"Elsevier Science","dateIssuedKey":"1990","dateIssuedDisp":"1990-","publisherPlace":"Amsterdam [u.a.]"}],"pubHistory":["Nachgewiesen 10.1990 -"],"note":["Gesehen am 05.02.20"],"id":{"issn":["1872-7727"],"zdb":["2005350-2"],"eki":["32044483X"]},"physDesc":[{"extent":"Online-Ressource"}],"recId":"32044483X","titleAlt":[{"title":"EJR"}],"part":{"extent":"8","volume":"82","pages":"e232-e239","year":"2013","issue":"5","text":"82(2013), 5, Seite e232-e239"},"language":["eng"]}],"name":{"displayForm":["Waldemar Hosch, Nina P. Hofmann, Dirk Mueller, Johannes Iwan, Gitsios Gitsioudis, Stefan Siebert, Evangelos Giannitsis, Hans U. Kauczor, Hugo A. Katus, Grigorios Korosoglou"]},"physDesc":[{"extent":"8 S."}],"id":{"doi":["10.1016/j.ejrad.2012.12.013"],"eki":["1775489582"]},"note":["Gesehen am 26.10.2021"],"origin":[{"dateIssuedDisp":"14 January 2013","dateIssuedKey":"2013"}],"title":[{"title":"Body mass index-adapted prospective coronary computed tomography angiography","subtitle":"determining the lowest limit for diagnostic purposes","title_sort":"Body mass index-adapted prospective coronary computed tomography angiography"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"person":[{"given":"Waldemar P.","role":"aut","family":"Hosch","display":"Hosch, Waldemar P."},{"given":"Nina","role":"aut","family":"Hofmann","display":"Hofmann, Nina"},{"family":"Mueller","display":"Mueller, Dirk","given":"Dirk","role":"aut"},{"family":"Iwan","display":"Iwan, Johannes","role":"aut","given":"Johannes"},{"given":"Gitsios","role":"aut","family":"Gitsioudis","display":"Gitsioudis, Gitsios"},{"role":"aut","given":"Stefan","display":"Siebert, Stefan","family":"Siebert"},{"given":"Evangelos","role":"aut","display":"Giannitsis, Evangelos","family":"Giannitsis"},{"display":"Kauczor, Hans-Ulrich","family":"Kauczor","role":"aut","given":"Hans-Ulrich"},{"display":"Katus, Hugo","family":"Katus","given":"Hugo","role":"aut"},{"display":"Korosoglou, Grigorios","family":"Korosoglou","role":"aut","given":"Grigorios"}]} 
SRT |a HOSCHWALDEBODYMASSIN1420