Body mass index-adapted prospective coronary computed tomography angiography: determining the lowest limit for diagnostic purposes
Purpose - To investigate the value of 4 different protocols for prospectively triggered 256-slice coronary computed tomography angiography (coronary CTA). - Methods - Two hundred and ten patients underwent prospectively triggered coronary CTA for suspected or known coronary artery disease (CAD). Pat...
Gespeichert in:
| Hauptverfasser: | , , , , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
14 January 2013
|
| In: |
European journal of radiology
Year: 2013, Jahrgang: 82, Heft: 5, Pages: e232-e239 |
| ISSN: | 1872-7727 |
| DOI: | 10.1016/j.ejrad.2012.12.013 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.ejrad.2012.12.013 Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0720048X12006419 |
| Verfasserangaben: | Waldemar Hosch, Nina P. Hofmann, Dirk Mueller, Johannes Iwan, Gitsios Gitsioudis, Stefan Siebert, Evangelos Giannitsis, Hans U. Kauczor, Hugo A. Katus, Grigorios Korosoglou |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1775489582 | ||
| 003 | DE-627 | ||
| 005 | 20230426125408.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 211026s2013 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.ejrad.2012.12.013 |2 doi | |
| 035 | |a (DE-627)1775489582 | ||
| 035 | |a (DE-599)KXP1775489582 | ||
| 035 | |a (OCoLC)1341422310 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Hosch, Waldemar P. |d 1969- |e VerfasserIn |0 (DE-588)11585696X |0 (DE-627)691639205 |0 (DE-576)290116562 |4 aut | |
| 245 | 1 | 0 | |a Body mass index-adapted prospective coronary computed tomography angiography |b determining the lowest limit for diagnostic purposes |c Waldemar Hosch, Nina P. Hofmann, Dirk Mueller, Johannes Iwan, Gitsios Gitsioudis, Stefan Siebert, Evangelos Giannitsis, Hans U. Kauczor, Hugo A. Katus, Grigorios Korosoglou |
| 264 | 1 | |c 14 January 2013 | |
| 300 | |a 8 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 26.10.2021 | ||
| 520 | |a Purpose - To investigate the value of 4 different protocols for prospectively triggered 256-slice coronary computed tomography angiography (coronary CTA). - Methods - Two hundred and ten patients underwent prospectively triggered coronary CTA for suspected or known coronary artery disease (CAD). Patients with heart rate >75bps before the scan despite ß-blocker administration and with arrhythmia were excluded. From January to September 2010, 60 patients underwent coronary CTA using a non-tailored protocol (120kV; 200mAs) and served as our ‘control’ group. From September 2010 to April 2012, based on the body mass index (BMI) of the examined patients (BMI subgroups of <25; 25-28; 28-30, and ≥30kg/m2) current tube voltage and tube current were: (1) slightly, (2) moderately or (3) strongly reduced, resulting into the 3 following BMI-adapted acquisition groups: (1) a ‘standard’ (100/120kV; 100-200mAs; n=50), 2) a ‘low dose’ (100/120kV; 75-150mAs; n=50), and 3) an ‘ultra-low dose’ (100/120kV; 50-100mAs; n=50) protocol. - Results - Patients examined using the non-tailored protocol exhibited the highest radiation exposure (3.2±0.4mSv), followed by the standard (1.6±0.7mSv), low-dose (1.2±0.6mSv) and ultra-low dose protocol (0.7±0.3mSv) (radiation savings of 50%, 63% and 78% respectively). Overall image quality was similar with standard dose (1.9±0.6) and low-dose (2.0±0.5) compared to the non-tailored group (1.9±0.5) (p=NS for all). In the ultra-low dose group however, image quality was significant reduced (2.7±0.6), p<0.05 versus all other groups). - Conclusion - Using BMI-adapted low dose acquisitions image quality can be maintained with simultaneous radiation savings of ∼65% (dose of ∼1mSv). This appears to be the lower limit for diagnostic coronary CTA, whereas ultra-low dose acquisitions result in significant image degradation. | ||
| 650 | 4 | |a 256-Slice computed tomography angiography | |
| 650 | 4 | |a Image quality | |
| 650 | 4 | |a Prospective ECG-triggering | |
| 650 | 4 | |a Radiation exposure | |
| 650 | 4 | |a Ultra-low dose coronary CTA | |
| 700 | 1 | |a Hofmann, Nina |d 1984- |e VerfasserIn |0 (DE-588)1019370645 |0 (DE-627)685028623 |0 (DE-576)357885821 |4 aut | |
| 700 | 1 | |a Mueller, Dirk |e VerfasserIn |4 aut | |
| 700 | 1 | |a Iwan, Johannes |e VerfasserIn |4 aut | |
| 700 | 1 | |a Gitsioudis, Gitsios |d 1981- |e VerfasserIn |0 (DE-588)138256209 |0 (DE-627)600669149 |0 (DE-576)30648174X |4 aut | |
| 700 | 1 | |a Siebert, Stefan |d 1973- |e VerfasserIn |0 (DE-588)139196080 |0 (DE-627)60903362X |0 (DE-576)310135303 |4 aut | |
| 700 | 1 | |a Giannitsis, Evangelos |e VerfasserIn |0 (DE-588)113336241 |0 (DE-627)577184091 |0 (DE-576)289759579 |4 aut | |
| 700 | 1 | |a Kauczor, Hans-Ulrich |d 1962- |e VerfasserIn |0 (DE-588)139267123 |0 (DE-627)70327113X |0 (DE-576)310955327 |4 aut | |
| 700 | 1 | |a Katus, Hugo |d 1951- |e VerfasserIn |0 (DE-588)108916618 |0 (DE-627)577155040 |0 (DE-576)289625076 |4 aut | |
| 700 | 1 | |a Korosoglou, Grigorios |d 1976- |e VerfasserIn |0 (DE-588)12854225X |0 (DE-627)374709025 |0 (DE-576)297204912 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t European journal of radiology |d Amsterdam [u.a.] : Elsevier Science, 1990 |g 82(2013), 5, Seite e232-e239 |h Online-Ressource |w (DE-627)32044483X |w (DE-600)2005350-2 |w (DE-576)099718138 |x 1872-7727 |7 nnas |a Body mass index-adapted prospective coronary computed tomography angiography determining the lowest limit for diagnostic purposes |
| 773 | 1 | 8 | |g volume:82 |g year:2013 |g number:5 |g pages:e232-e239 |g extent:8 |a Body mass index-adapted prospective coronary computed tomography angiography determining the lowest limit for diagnostic purposes |
| 856 | 4 | 0 | |u https://doi.org/10.1016/j.ejrad.2012.12.013 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://www.sciencedirect.com/science/article/pii/S0720048X12006419 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20211026 | ||
| 993 | |a Article | ||
| 994 | |a 2013 | ||
| 998 | |g 12854225X |a Korosoglou, Grigorios |m 12854225X:Korosoglou, Grigorios |d 910000 |d 910100 |e 910000PK12854225X |e 910100PK12854225X |k 0/910000/ |k 1/910000/910100/ |p 10 | ||
| 998 | |g 108916618 |a Katus, Hugo |m 108916618:Katus, Hugo |d 910000 |d 910100 |e 910000PK108916618 |e 910100PK108916618 |k 0/910000/ |k 1/910000/910100/ |p 9 | ||
| 998 | |g 139267123 |a Kauczor, Hans-Ulrich |m 139267123:Kauczor, Hans-Ulrich |d 910000 |d 911400 |e 910000PK139267123 |e 911400PK139267123 |k 0/910000/ |k 1/910000/911400/ |p 8 |y j | ||
| 998 | |g 113336241 |a Giannitsis, Evangelos |m 113336241:Giannitsis, Evangelos |d 910000 |d 910100 |e 910000PG113336241 |e 910100PG113336241 |k 0/910000/ |k 1/910000/910100/ |p 7 | ||
| 998 | |g 139196080 |a Siebert, Stefan |m 139196080:Siebert, Stefan |d 910000 |d 911400 |e 910000PS139196080 |e 911400PS139196080 |k 0/910000/ |k 1/910000/911400/ |p 6 | ||
| 998 | |g 138256209 |a Gitsioudis, Gitsios |m 138256209:Gitsioudis, Gitsios |d 910000 |d 910100 |e 910000PG138256209 |e 910100PG138256209 |k 0/910000/ |k 1/910000/910100/ |p 5 | ||
| 998 | |g 1019370645 |a Hofmann, Nina |m 1019370645:Hofmann, Nina |p 2 | ||
| 998 | |g 11585696X |a Hosch, Waldemar P. |m 11585696X:Hosch, Waldemar P. |d 50000 |e 50000PH11585696X |k 0/50000/ |p 1 |x j | ||
| 999 | |a KXP-PPN1775489582 |e 3996506902 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"recId":"1775489582","relHost":[{"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"Body mass index-adapted prospective coronary computed tomography angiography determining the lowest limit for diagnostic purposesEuropean journal of radiology","title":[{"subtitle":"EJR","title_sort":"European journal of radiology","title":"European journal of radiology"}],"origin":[{"publisher":"Elsevier Science","dateIssuedKey":"1990","dateIssuedDisp":"1990-","publisherPlace":"Amsterdam [u.a.]"}],"pubHistory":["Nachgewiesen 10.1990 -"],"note":["Gesehen am 05.02.20"],"id":{"issn":["1872-7727"],"zdb":["2005350-2"],"eki":["32044483X"]},"physDesc":[{"extent":"Online-Ressource"}],"recId":"32044483X","titleAlt":[{"title":"EJR"}],"part":{"extent":"8","volume":"82","pages":"e232-e239","year":"2013","issue":"5","text":"82(2013), 5, Seite e232-e239"},"language":["eng"]}],"name":{"displayForm":["Waldemar Hosch, Nina P. Hofmann, Dirk Mueller, Johannes Iwan, Gitsios Gitsioudis, Stefan Siebert, Evangelos Giannitsis, Hans U. Kauczor, Hugo A. Katus, Grigorios Korosoglou"]},"physDesc":[{"extent":"8 S."}],"id":{"doi":["10.1016/j.ejrad.2012.12.013"],"eki":["1775489582"]},"note":["Gesehen am 26.10.2021"],"origin":[{"dateIssuedDisp":"14 January 2013","dateIssuedKey":"2013"}],"title":[{"title":"Body mass index-adapted prospective coronary computed tomography angiography","subtitle":"determining the lowest limit for diagnostic purposes","title_sort":"Body mass index-adapted prospective coronary computed tomography angiography"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"person":[{"given":"Waldemar P.","role":"aut","family":"Hosch","display":"Hosch, Waldemar P."},{"given":"Nina","role":"aut","family":"Hofmann","display":"Hofmann, Nina"},{"family":"Mueller","display":"Mueller, Dirk","given":"Dirk","role":"aut"},{"family":"Iwan","display":"Iwan, Johannes","role":"aut","given":"Johannes"},{"given":"Gitsios","role":"aut","family":"Gitsioudis","display":"Gitsioudis, Gitsios"},{"role":"aut","given":"Stefan","display":"Siebert, Stefan","family":"Siebert"},{"given":"Evangelos","role":"aut","display":"Giannitsis, Evangelos","family":"Giannitsis"},{"display":"Kauczor, Hans-Ulrich","family":"Kauczor","role":"aut","given":"Hans-Ulrich"},{"display":"Katus, Hugo","family":"Katus","given":"Hugo","role":"aut"},{"display":"Korosoglou, Grigorios","family":"Korosoglou","role":"aut","given":"Grigorios"}]} | ||
| SRT | |a HOSCHWALDEBODYMASSIN1420 | ||