Quadriceps tendon vs. patellar tendon autograft for ACL reconstruction using a hardware-free press-fit fixation technique: comparable stability, function and return-to-sport level but less donor site morbidity in athletes after 10 years
The use of quadriceps tendon-patellar bone (QTB) autograft for anterior cruciate ligament (ACL) reconstruction is gaining momentum. Yet, long-term results that compare this procedure with established methods are lacking. The aim of this study was to report and compare long-term results of ACL recons...
Gespeichert in:
| Hauptverfasser: | , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
5 June 2020
|
| In: |
Archives of orthopaedic and trauma surgery
Year: 2020, Jahrgang: 140, Heft: 10, Pages: 1465-1474 |
| ISSN: | 1434-3916 |
| DOI: | 10.1007/s00402-020-03508-1 |
| Online-Zugang: | Verlag, kostenfrei, Volltext: https://doi.org/10.1007/s00402-020-03508-1 |
| Verfasserangaben: | Alexander Barié, Thomas Sprinckstub, Jürgen Huber, Ayham Jaber |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1775565432 | ||
| 003 | DE-627 | ||
| 005 | 20220208230134.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 211027s2020 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1007/s00402-020-03508-1 |2 doi | |
| 035 | |a (DE-627)1775565432 | ||
| 035 | |a (DE-599)KXP1775565432 | ||
| 035 | |a (OCoLC)1295680345 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Barié, Alexander |d 1972- |e VerfasserIn |0 (DE-588)131983652 |0 (DE-627)516334611 |0 (DE-576)29887637X |4 aut | |
| 245 | 1 | 0 | |a Quadriceps tendon vs. patellar tendon autograft for ACL reconstruction using a hardware-free press-fit fixation technique |b comparable stability, function and return-to-sport level but less donor site morbidity in athletes after 10 years |c Alexander Barié, Thomas Sprinckstub, Jürgen Huber, Ayham Jaber |
| 246 | 3 | 0 | |a ten |
| 264 | 1 | |c 5 June 2020 | |
| 300 | |a 10 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 27.10.2021 | ||
| 520 | |a The use of quadriceps tendon-patellar bone (QTB) autograft for anterior cruciate ligament (ACL) reconstruction is gaining momentum. Yet, long-term results that compare this procedure with established methods are lacking. The aim of this study was to report and compare long-term results of ACL reconstruction using QTB autografts versus bone-patellar tendon-bone (BPTB) autografts, both anchored using a hardware-free press-fit fixation technique. | ||
| 700 | 1 | |a Sprinckstub, Thomas |e VerfasserIn |4 aut | |
| 700 | 1 | |a Huber, Jürgen |e VerfasserIn |4 aut | |
| 700 | 1 | |a Jaber, Ayham |d 1992- |e VerfasserIn |0 (DE-588)1170710190 |0 (DE-627)1039879845 |0 (DE-576)512609756 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Archives of orthopaedic and trauma surgery |d Berlin : Springer, 1989 |g 140(2020), 10, Seite 1465-1474 |h Online-Ressource |w (DE-627)253390087 |w (DE-600)1458452-9 |w (DE-576)072283297 |x 1434-3916 |7 nnas |a Quadriceps tendon vs. patellar tendon autograft for ACL reconstruction using a hardware-free press-fit fixation technique comparable stability, function and return-to-sport level but less donor site morbidity in athletes after 10 years |
| 773 | 1 | 8 | |g volume:140 |g year:2020 |g number:10 |g pages:1465-1474 |g extent:10 |a Quadriceps tendon vs. patellar tendon autograft for ACL reconstruction using a hardware-free press-fit fixation technique comparable stability, function and return-to-sport level but less donor site morbidity in athletes after 10 years |
| 856 | 4 | 0 | |u https://doi.org/10.1007/s00402-020-03508-1 |x Verlag |x Resolving-System |z kostenfrei |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20211027 | ||
| 993 | |a Article | ||
| 994 | |a 2020 | ||
| 998 | |g 1170710190 |a Jaber, Ayham |m 1170710190:Jaber, Ayham |d 910000 |d 911400 |e 910000PJ1170710190 |e 911400PJ1170710190 |k 0/910000/ |k 1/910000/911400/ |p 4 |y j | ||
| 998 | |g 131983652 |a Barié, Alexander |m 131983652:Barié, Alexander |p 1 |x j | ||
| 999 | |a KXP-PPN1775565432 |e 3996770189 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"language":["eng"],"origin":[{"dateIssuedKey":"2020","dateIssuedDisp":"5 June 2020"}],"note":["Gesehen am 27.10.2021"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"title":[{"title":"Quadriceps tendon vs. patellar tendon autograft for ACL reconstruction using a hardware-free press-fit fixation technique","title_sort":"Quadriceps tendon vs. patellar tendon autograft for ACL reconstruction using a hardware-free press-fit fixation technique","subtitle":"comparable stability, function and return-to-sport level but less donor site morbidity in athletes after 10 years"}],"person":[{"display":"Barié, Alexander","family":"Barié","role":"aut","given":"Alexander"},{"given":"Thomas","role":"aut","family":"Sprinckstub","display":"Sprinckstub, Thomas"},{"given":"Jürgen","role":"aut","family":"Huber","display":"Huber, Jürgen"},{"display":"Jaber, Ayham","family":"Jaber","role":"aut","given":"Ayham"}],"relHost":[{"id":{"eki":["253390087"],"issn":["1434-3916"],"zdb":["1458452-9"]},"physDesc":[{"extent":"Online-Ressource"}],"recId":"253390087","pubHistory":["Volume 108, issue 1 (January 1989)-"],"part":{"issue":"10","extent":"10","volume":"140","year":"2020","text":"140(2020), 10, Seite 1465-1474","pages":"1465-1474"},"note":["Gesehen am 28.03.25","Fortsetzung der Druck-Ausgabe"],"titleAlt":[{"title":"Orthopaedic and trauma surgery"}],"origin":[{"publisherPlace":"Berlin ; Heidelberg","dateIssuedDisp":"1989-","publisher":"Springer","dateIssuedKey":"1989"}],"title":[{"title_sort":"Archives of orthopaedic and trauma surgery","title":"Archives of orthopaedic and trauma surgery"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"language":["eng"],"disp":"Quadriceps tendon vs. patellar tendon autograft for ACL reconstruction using a hardware-free press-fit fixation technique comparable stability, function and return-to-sport level but less donor site morbidity in athletes after 10 yearsArchives of orthopaedic and trauma surgery"}],"id":{"eki":["1775565432"],"doi":["10.1007/s00402-020-03508-1"]},"recId":"1775565432","name":{"displayForm":["Alexander Barié, Thomas Sprinckstub, Jürgen Huber, Ayham Jaber"]},"physDesc":[{"extent":"10 S."}]} | ||
| SRT | |a BARIEALEXAQUADRICEPS5202 | ||