Detection of acute pulmonary embolism: feasibility of diagnostic accuracy of MRI using a stepwise protocol

Multidetector computed tomography (MDCT) has become the imaging method of choice in patients suspected of having pulmonary embolism (PE) but has the inherent limitation of radiation dose and the side effects of contrast agents. The purpose of the study was to assess the feasibility of a stepwise MRI...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Hosch, Waldemar P. (VerfasserIn) , Schlieter, Martin (VerfasserIn) , Ley, Sebastian (VerfasserIn) , Heye, Tobias (VerfasserIn) , Kauczor, Hans-Ulrich (VerfasserIn) , Libicher, Martin (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2014
In: Emergency radiology
Year: 2014, Jahrgang: 21, Heft: 2, Pages: 151-158
ISSN:1438-1435
DOI:10.1007/s10140-013-1176-y
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1007/s10140-013-1176-y
Volltext
Verfasserangaben:Waldemar Hosch, Martin Schlieter, Sebastian Ley, Tobias Heye, Hans-Ulrich Kauczor, Martin Libicher

MARC

LEADER 00000caa a2200000 c 4500
001 1775693422
003 DE-627
005 20240414193528.0
007 cr uuu---uuuuu
008 211029s2014 xx |||||o 00| ||eng c
024 7 |a 10.1007/s10140-013-1176-y  |2 doi 
035 |a (DE-627)1775693422 
035 |a (DE-599)KXP1775693422 
035 |a (OCoLC)1341422443 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Hosch, Waldemar P.  |d 1969-  |e VerfasserIn  |0 (DE-588)11585696X  |0 (DE-627)691639205  |0 (DE-576)290116562  |4 aut 
245 1 0 |a Detection of acute pulmonary embolism  |b feasibility of diagnostic accuracy of MRI using a stepwise protocol  |c Waldemar Hosch, Martin Schlieter, Sebastian Ley, Tobias Heye, Hans-Ulrich Kauczor, Martin Libicher 
264 1 |c 2014 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 29.10.2021 
500 |a Published online: 27 November 2013 
520 |a Multidetector computed tomography (MDCT) has become the imaging method of choice in patients suspected of having pulmonary embolism (PE) but has the inherent limitation of radiation dose and the side effects of contrast agents. The purpose of the study was to assess the feasibility of a stepwise MRI protocol in the clinical setting of acute PE. The stepwise approach should make it possible to diagnose acute PE in critically ill patients using fast MR sequences and included the option to add comprehensive sequences when patients were stable. Forty-five patients with acute PE (26 men, 19 women; 41 ± 16 years) were included in this prospective study. The diagnosis was initially confirmed by MDCT as gold standard. MRI at 1.5 T was subsequently performed without any delay in medical treatment. The MRI protocol proceeded stepwise from robust to detailed imaging techniques (i.e., from TrueFISP and single shot HASTE sequence to MR perfusion and 3D-MR angiography) if the patient was able to tolerate additional imaging time. Diagnostic accuracy was evaluated on the central (lobar) and peripheral (segmental) levels. The complete MR protocol was applied in 40 of the 45 patients (88 %). In the remaining five patients with severe dyspnea the diagnosis of acute PE was established by using fast TrueFISP sequences that were insensitive to respiratory movement. All five patients suffered from a major central PE. Highest sensitivity was achieved by MR perfusion (lobar, 98 %; segmental, 95 %). Real-time TrueFISP and MR angiography showed the highest specificity (lobar, 90-100 %; segmental, 95-97 %). The combination of all MR sequences matched closely the results of MDCT (lobar: sensitivity 98 %, specificity 100 %; segmental: sensitivity 95 %, specificity 97 %). MRI using a stepwise protocol is a promising approach for diagnosing acute PE. The protocol can be tailored for dyspneic patients with central PE using real-time MRI sequences. The diagnostic accuracy for peripheral PE can be improved by using combined MR techniques, achieving comparable results to MDCT. 
700 1 |a Schlieter, Martin  |d 1973-  |e VerfasserIn  |0 (DE-588)1023648806  |0 (DE-627)718423402  |0 (DE-576)367213516  |4 aut 
700 1 |a Ley, Sebastian  |d 1974-  |e VerfasserIn  |0 (DE-588)123561256  |0 (DE-627)706346858  |0 (DE-576)293766835  |4 aut 
700 1 |a Heye, Tobias  |d 1976-  |e VerfasserIn  |0 (DE-588)133300943  |0 (DE-627)691326002  |0 (DE-576)271430303  |4 aut 
700 1 |a Kauczor, Hans-Ulrich  |d 1962-  |e VerfasserIn  |0 (DE-588)139267123  |0 (DE-627)70327113X  |0 (DE-576)310955327  |4 aut 
700 1 |a Libicher, Martin  |e VerfasserIn  |0 (DE-588)107649448X  |0 (DE-627)834952416  |0 (DE-576)168976617  |4 aut 
773 0 8 |i Enthalten in  |t Emergency radiology  |d Heidelberg : Springer, 1994  |g 21(2014), 2, Seite 151-158  |h Online-Ressource  |w (DE-627)271599332  |w (DE-600)1480928-X  |w (DE-576)113948239  |x 1438-1435  |7 nnas  |a Detection of acute pulmonary embolism feasibility of diagnostic accuracy of MRI using a stepwise protocol 
773 1 8 |g volume:21  |g year:2014  |g number:2  |g pages:151-158  |g extent:8  |a Detection of acute pulmonary embolism feasibility of diagnostic accuracy of MRI using a stepwise protocol 
856 4 0 |u https://doi.org/10.1007/s10140-013-1176-y  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20211029 
993 |a Article 
994 |a 2013 
998 |g 107649448X  |a Libicher, Martin  |m 107649448X:Libicher, Martin  |d 50000  |e 50000PL107649448X  |k 0/50000/  |p 6  |y j 
998 |g 139267123  |a Kauczor, Hans-Ulrich  |m 139267123:Kauczor, Hans-Ulrich  |d 910000  |d 911400  |e 910000PK139267123  |e 911400PK139267123  |k 0/910000/  |k 1/910000/911400/  |p 5 
998 |g 133300943  |a Heye, Tobias  |m 133300943:Heye, Tobias  |d 910000  |d 911400  |e 910000PH133300943  |e 911400PH133300943  |k 0/910000/  |k 1/910000/911400/  |p 4 
998 |g 123561256  |a Ley, Sebastian  |m 123561256:Ley, Sebastian  |p 3 
998 |g 11585696X  |a Hosch, Waldemar P.  |m 11585696X:Hosch, Waldemar P.  |d 50000  |e 50000PH11585696X  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN1775693422  |e 3997196281 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"note":["Gesehen am 29.10.2021","Published online: 27 November 2013"],"title":[{"subtitle":"feasibility of diagnostic accuracy of MRI using a stepwise protocol","title":"Detection of acute pulmonary embolism","title_sort":"Detection of acute pulmonary embolism"}],"origin":[{"dateIssuedDisp":"2014","dateIssuedKey":"2014"}],"relHost":[{"title":[{"title":"Emergency radiology","title_sort":"Emergency radiology","subtitle":"a journal of practical imaging"}],"note":["Gesehen am 28.11.08"],"type":{"media":"Online-Ressource","bibl":"periodical"},"language":["eng"],"origin":[{"dateIssuedDisp":"1994-","dateIssuedKey":"1994","publisherPlace":"Heidelberg ; New York ; Baltimore, Md.","publisher":"Springer ; Williams & Wilkins"}],"disp":"Detection of acute pulmonary embolism feasibility of diagnostic accuracy of MRI using a stepwise protocolEmergency radiology","recId":"271599332","physDesc":[{"extent":"Online-Ressource"}],"part":{"volume":"21","year":"2014","extent":"8","text":"21(2014), 2, Seite 151-158","issue":"2","pages":"151-158"},"id":{"eki":["271599332"],"issn":["1438-1435"],"zdb":["1480928-X"]},"pubHistory":["1.1994 -"],"name":{"displayForm":["official journal of the American Society of Emergency Radiology"]}}],"person":[{"display":"Hosch, Waldemar P.","family":"Hosch","role":"aut","given":"Waldemar P."},{"family":"Schlieter","given":"Martin","role":"aut","display":"Schlieter, Martin"},{"family":"Ley","role":"aut","given":"Sebastian","display":"Ley, Sebastian"},{"given":"Tobias","role":"aut","family":"Heye","display":"Heye, Tobias"},{"family":"Kauczor","role":"aut","given":"Hans-Ulrich","display":"Kauczor, Hans-Ulrich"},{"family":"Libicher","role":"aut","given":"Martin","display":"Libicher, Martin"}],"physDesc":[{"extent":"8 S."}],"recId":"1775693422","id":{"doi":["10.1007/s10140-013-1176-y"],"eki":["1775693422"]},"name":{"displayForm":["Waldemar Hosch, Martin Schlieter, Sebastian Ley, Tobias Heye, Hans-Ulrich Kauczor, Martin Libicher"]}} 
SRT |a HOSCHWALDEDETECTIONO2014