Does dual plating clavicle fractures increase the risk of refracture after hardware removal?: a biomechanical investigation

Background - Dual orthogonal plating of midshaft clavicle fractures is increasingly used for osteosynthesis. The risk of refracture after hardware removal remains unknown. The purpose of this study was to compare the torsional and 3-point bending loads to failure of the clavicle following removal of...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Ruzbarsky, Joseph J. (VerfasserIn) , Nolte, Philip-Christian (VerfasserIn) , Miles, Jon W. (VerfasserIn) , Tanghe, Kira K. (VerfasserIn) , Nolte, Anna-Katharina (VerfasserIn) , Hackett, Thomas R. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 8 February 2021
In: Journal of shoulder and elbow surgery
Year: 2021, Jahrgang: 30, Heft: 9, Pages: e594-e601
ISSN:1532-6500
DOI:10.1016/j.jse.2020.12.026
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.jse.2020.12.026
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S1058274621000926
Volltext
Verfasserangaben:Joseph J. Ruzbarsky, MD, Philip-C. Nolte, MD, MA, Jon W. Miles, MSc, Kira K. Tanghe, BS, Anna-K. Tross, MD, Thomas R. Hackett, MD

MARC

LEADER 00000caa a2200000 c 4500
001 1776045637
003 DE-627
005 20240414193536.0
007 cr uuu---uuuuu
008 211103s2021 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.jse.2020.12.026  |2 doi 
035 |a (DE-627)1776045637 
035 |a (DE-599)KXP1776045637 
035 |a (OCoLC)1341422466 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Ruzbarsky, Joseph J.  |e VerfasserIn  |0 (DE-588)124496378X  |0 (DE-627)177604603X  |4 aut 
245 1 0 |a Does dual plating clavicle fractures increase the risk of refracture after hardware removal?  |b a biomechanical investigation  |c Joseph J. Ruzbarsky, MD, Philip-C. Nolte, MD, MA, Jon W. Miles, MSc, Kira K. Tanghe, BS, Anna-K. Tross, MD, Thomas R. Hackett, MD 
264 1 |c 8 February 2021 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 03.11.2021 
520 |a Background - Dual orthogonal plating of midshaft clavicle fractures is increasingly used for osteosynthesis. The risk of refracture after hardware removal remains unknown. The purpose of this study was to compare the torsional and 3-point bending loads to failure of the clavicle following removal of single-plane, superior 3.5-mm plate fixation vs. dual orthogonal plating 2.7-mm constructs. - Methods - This study used 12 pairs of clavicles (N = 24) harvested from cadaveric specimens with a mean age at death of 56.5 years (range, 46-65 years). One clavicle from each pair was randomly assigned to either superior plating (SP, n = 12) or double plating (DP, n = 12). For SP, a superior 3.5-mm plate was used as a template to drill 3 bicortical 2.8-mm holes medial and lateral to the center of the clavicle. For DP, two 2.7-mm plates were used as a template to drill 4 bicortical 2.0-mm holes medial and lateral to the center of the clavicle. Clavicle pairs were randomly and evenly distributed to undergo either 3-point bending (n = 12) or posterior torsional loading (n = 12). Cyclic loading was performed, followed by load-to-failure testing. Stiffness, displacement at failure, load to failure, and failure mode were assessed and compared between SP and DP constructs. - Results - No significant differences between the SP and DP groups were observed for stiffness (768.2 ± 281.3 N/mm vs. 785.5 ± 315.0 N/mm, P = .872), displacement at failure (8.1 ± 2.8 mm vs. 5.4 ± 1.2 mm, P = .150), and ultimate load at failure (1831.0 ± 229.6 N vs. 1842.0 ± 662.4 N, P = .964) under the condition of 3-point bending. Similarly, no significant differences between the SP and DP groups were observed for torsional stiffness (1.3 ± 0.8 N · m/° vs. 1.1 ± 0.4 N · m/°, P = .844), rotation at failure (17.3° ± 4.4° vs. 14.4° ± 1.2°, P = .205), and ultimate torque at failure (14.8 ± 6.5 N · m vs. 14.7 ± 6.9 N · m, P = .103) under the condition of posterior torsional loading. The most common mode of failure for 3-point bending testing was an oblique fracture (7 of 12 clavicles, 58.3%), with no significant difference between groups (3 of 6 in SP group [50%] vs. 4 of 6 in DP group [66.7%], P > .999). The most common mode of failure with posterior torsional loading was a spiral fracture (10 of 12 clavicles, 83.3%), with no significant difference between groups (4 of 6 in SP group [66.7%] vs. 6 of 6 in DP group [100%], P = .455). - Conclusion - Following clavicle plate removal of either DP or SP, there is no statistically significant difference in the amount of force, under the condition of 3-point bending or torsional loading, required to fracture the diaphyseal clavicle in vitro. 
650 4 |a biomechanical 
650 4 |a Clavicle fracture 
650 4 |a dual plating 
650 4 |a hardware removal 
650 4 |a refracture 
650 4 |a superior plating 
700 1 |a Nolte, Philip-Christian  |d 1987-  |e VerfasserIn  |0 (DE-588)105698712X  |0 (DE-627)794361757  |0 (DE-576)41297102X  |4 aut 
700 1 |a Miles, Jon W.  |e VerfasserIn  |4 aut 
700 1 |a Tanghe, Kira K.  |e VerfasserIn  |4 aut 
700 1 |a Nolte, Anna-Katharina  |d 1989-  |e VerfasserIn  |0 (DE-588)1123233217  |0 (DE-627)87657942X  |0 (DE-576)481684441  |4 aut 
700 1 |a Hackett, Thomas R.  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Journal of shoulder and elbow surgery  |d St. Louis, Mo. : Mosby, 1992  |g 30(2021), 9 vom: Sept., Seite e594-e601  |h Online-Ressource  |w (DE-627)32927029X  |w (DE-600)2046901-9  |w (DE-576)09442716X  |x 1532-6500  |7 nnas  |a Does dual plating clavicle fractures increase the risk of refracture after hardware removal? a biomechanical investigation 
773 1 8 |g volume:30  |g year:2021  |g number:9  |g month:09  |g pages:e594-e601  |g extent:8  |a Does dual plating clavicle fractures increase the risk of refracture after hardware removal? a biomechanical investigation 
856 4 0 |u https://doi.org/10.1016/j.jse.2020.12.026  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S1058274621000926  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20211103 
993 |a Article 
994 |a 2021 
998 |g 1123233217  |a Nolte, Anna-Katharina  |m 1123233217:Nolte, Anna-Katharina  |d 910000  |d 911460  |e 910000PN1123233217  |e 911460PN1123233217  |k 0/910000/  |k 1/910000/911460/  |p 5 
998 |g 105698712X  |a Nolte, Philip-Christian  |m 105698712X:Nolte, Philip-Christian  |d 50000  |e 50000PN105698712X  |k 0/50000/  |p 2 
999 |a KXP-PPN1776045637  |e 3998898174 
BIB |a Y 
SER |a journal 
JSO |a {"physDesc":[{"extent":"8 S."}],"relHost":[{"recId":"32927029X","language":["eng"],"note":["Gesehen am 19.02.20"],"type":{"media":"Online-Ressource","bibl":"periodical"},"disp":"Does dual plating clavicle fractures increase the risk of refracture after hardware removal? a biomechanical investigationJournal of shoulder and elbow surgery","part":{"issue":"9","pages":"e594-e601","year":"2021","extent":"8","text":"30(2021), 9 vom: Sept., Seite e594-e601","volume":"30"},"pubHistory":["1.1992 -"],"title":[{"title_sort":"Journal of shoulder and elbow surgery","title":"Journal of shoulder and elbow surgery"}],"physDesc":[{"extent":"Online-Ressource"}],"id":{"eki":["32927029X"],"zdb":["2046901-9"],"issn":["1532-6500"]},"origin":[{"dateIssuedDisp":"1992-","publisher":"Mosby","dateIssuedKey":"1992","publisherPlace":"St. Louis, Mo."}]}],"name":{"displayForm":["Joseph J. Ruzbarsky, MD, Philip-C. Nolte, MD, MA, Jon W. Miles, MSc, Kira K. Tanghe, BS, Anna-K. Tross, MD, Thomas R. Hackett, MD"]},"origin":[{"dateIssuedKey":"2021","dateIssuedDisp":"8 February 2021"}],"id":{"doi":["10.1016/j.jse.2020.12.026"],"eki":["1776045637"]},"note":["Gesehen am 03.11.2021"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"recId":"1776045637","language":["eng"],"person":[{"family":"Ruzbarsky","given":"Joseph J.","roleDisplay":"VerfasserIn","display":"Ruzbarsky, Joseph J.","role":"aut"},{"given":"Philip-Christian","family":"Nolte","role":"aut","roleDisplay":"VerfasserIn","display":"Nolte, Philip-Christian"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Miles, Jon W.","given":"Jon W.","family":"Miles"},{"display":"Tanghe, Kira K.","roleDisplay":"VerfasserIn","role":"aut","family":"Tanghe","given":"Kira K."},{"given":"Anna-Katharina","family":"Nolte","role":"aut","display":"Nolte, Anna-Katharina","roleDisplay":"VerfasserIn"},{"given":"Thomas R.","family":"Hackett","role":"aut","roleDisplay":"VerfasserIn","display":"Hackett, Thomas R."}],"title":[{"title":"Does dual plating clavicle fractures increase the risk of refracture after hardware removal?","subtitle":"a biomechanical investigation","title_sort":"Does dual plating clavicle fractures increase the risk of refracture after hardware removal?"}]} 
SRT |a RUZBARSKYJDOESDUALPL8202