CT volumetry of artificial pulmonary nodules using an ex vivo lung phantom: influence of exposure parameters and iterative reconstruction on reproducibility

Objectives - To evaluate the influence of exposure parameters and raw-data based iterative reconstruction (IR) on the measurement variability of computer-aided nodule volumetry on chest multidetector computed tomography (MDCT). - Materials and methods - N=7 porcine lung explants were inflated in a d...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Wielpütz, Mark Oliver (VerfasserIn) , Lederlin, Mathieu (VerfasserIn) , Wroblewski, Jacek (VerfasserIn) , Dinkel, Julien (VerfasserIn) , Eichinger, Monika (VerfasserIn) , Biederer, Jürgen (VerfasserIn) , Kauczor, Hans-Ulrich (VerfasserIn) , Puderbach, Michael (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 31 May 2013
In: European journal of radiology
Year: 2013, Jahrgang: 82, Heft: 9, Pages: 1577-1583
ISSN:1872-7727
DOI:10.1016/j.ejrad.2013.04.035
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.ejrad.2013.04.035
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0720048X13002325
Volltext
Verfasserangaben:Mark O. Wielpütz, Mathieu Lederlin, Jacek Wroblewski, Julien Dinkel, Monika Eichinger, Jürgen Biederer, Hans-Ulrich Kauczor, Michael Puderbach

MARC

LEADER 00000caa a2200000 c 4500
001 1776305434
003 DE-627
005 20220820071626.0
007 cr uuu---uuuuu
008 211108s2013 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.ejrad.2013.04.035  |2 doi 
035 |a (DE-627)1776305434 
035 |a (DE-599)KXP1776305434 
035 |a (OCoLC)1341423450 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Wielpütz, Mark Oliver  |d 1982-  |e VerfasserIn  |0 (DE-588)139999752  |0 (DE-627)614754682  |0 (DE-576)314127046  |4 aut 
245 1 0 |a CT volumetry of artificial pulmonary nodules using an ex vivo lung phantom  |b influence of exposure parameters and iterative reconstruction on reproducibility  |c Mark O. Wielpütz, Mathieu Lederlin, Jacek Wroblewski, Julien Dinkel, Monika Eichinger, Jürgen Biederer, Hans-Ulrich Kauczor, Michael Puderbach 
264 1 |c 31 May 2013 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 08.11.2021 
520 |a Objectives - To evaluate the influence of exposure parameters and raw-data based iterative reconstruction (IR) on the measurement variability of computer-aided nodule volumetry on chest multidetector computed tomography (MDCT). - Materials and methods - N=7 porcine lung explants were inflated in a dedicated ex vivo phantom and prepared with n=162 artificial nodules. MDCT was performed eight consecutive times (combinations of 120 and 80kV with 120, 60, 30 and 12mAs), and reconstructed with filtered back projection (FBP) and IR. Nodule volume and diameter were measured semi-automatically with dedicated software. The absolute percentage measurement error (APE) was computed in relation to the 120kV 120mAs acquisition. Noise was recorded for each nodule in every dataset. - Results - Mean nodule volume and diameter were 0.32±0.15ml and 12.0±2.6mm, respectively. Although IR reduced noise by 24.9% on average compared to FBP (p<0.007), APE with IR was equal to or slightly higher than with FBP. Mean APE for volume increased significantly below a volume computed tomography dose index (CTDI) of 1.0mGy: for 120kV 12mAs APE was 3.8±6.2% (FBP) vs. 4.0±5.2% (IR) (p<0.007); for 80kV 12mAs APE was 8.0±13.0% vs. 9.3±15.8% (n.s.), respectively. Correlating APE with image noise revealed that at identical noise APE was higher with IR than with FBP (p<0.05). - Conclusions - Computer-aided volumetry is robust in a wide range of exposure settings, and reproducibility is reduced at a CTDI below 1.0mGy only, but the error rate remains clinically irrelevant. Noise reduction by IR is not detrimental for measurement error in the setting of semi-automatic nodule volumetry on chest MDCT. 
650 4 |a Computer-aided diagnosis 
650 4 |a Lung cancer 
650 4 |a Screening 
700 1 |a Lederlin, Mathieu  |e VerfasserIn  |0 (DE-588)1156758319  |0 (DE-627)1019695811  |0 (DE-576)502424540  |4 aut 
700 1 |a Wroblewski, Jacek  |d 1982-  |e VerfasserIn  |0 (DE-588)1136449035  |0 (DE-627)892933798  |0 (DE-576)490553729  |4 aut 
700 1 |a Dinkel, Julien  |d 1978-  |e VerfasserIn  |0 (DE-588)140755632  |0 (DE-627)621592773  |0 (DE-576)320647374  |4 aut 
700 1 |a Eichinger, Monika  |d 1964-  |e VerfasserIn  |0 (DE-588)1049617525  |0 (DE-627)78269117X  |0 (DE-576)172609712  |4 aut 
700 1 |a Biederer, Jürgen  |d 1969-  |e VerfasserIn  |0 (DE-588)141247282  |0 (DE-627)625830857  |0 (DE-576)322978122  |4 aut 
700 1 |a Kauczor, Hans-Ulrich  |d 1962-  |e VerfasserIn  |0 (DE-588)139267123  |0 (DE-627)70327113X  |0 (DE-576)310955327  |4 aut 
700 1 |a Puderbach, Michael  |d 1974-  |e VerfasserIn  |0 (DE-588)123953669  |0 (DE-627)085545880  |0 (DE-576)293957452  |4 aut 
773 0 8 |i Enthalten in  |t European journal of radiology  |d Amsterdam [u.a.] : Elsevier Science, 1990  |g 82(2013), 9, Seite 1577-1583  |h Online-Ressource  |w (DE-627)32044483X  |w (DE-600)2005350-2  |w (DE-576)099718138  |x 1872-7727  |7 nnas  |a CT volumetry of artificial pulmonary nodules using an ex vivo lung phantom influence of exposure parameters and iterative reconstruction on reproducibility 
773 1 8 |g volume:82  |g year:2013  |g number:9  |g pages:1577-1583  |g extent:7  |a CT volumetry of artificial pulmonary nodules using an ex vivo lung phantom influence of exposure parameters and iterative reconstruction on reproducibility 
856 4 0 |u https://doi.org/10.1016/j.ejrad.2013.04.035  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0720048X13002325  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20211108 
993 |a Article 
994 |a 2013 
998 |g 123953669  |a Puderbach, Michael  |m 123953669:Puderbach, Michael  |d 910000  |d 950000  |d 950900  |e 910000PP123953669  |e 950000PP123953669  |e 950900PP123953669  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950900/  |p 8  |y j 
998 |g 139267123  |a Kauczor, Hans-Ulrich  |m 139267123:Kauczor, Hans-Ulrich  |d 910000  |d 911400  |e 910000PK139267123  |e 911400PK139267123  |k 0/910000/  |k 1/910000/911400/  |p 7 
998 |g 141247282  |a Biederer, Jürgen  |m 141247282:Biederer, Jürgen  |d 910000  |d 911400  |e 910000PB141247282  |e 911400PB141247282  |k 0/910000/  |k 1/910000/911400/  |p 6 
998 |g 1049617525  |a Eichinger, Monika  |m 1049617525:Eichinger, Monika  |d 910000  |d 950000  |d 950900  |e 910000PE1049617525  |e 950000PE1049617525  |e 950900PE1049617525  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950900/  |p 5 
998 |g 140755632  |a Dinkel, Julien  |m 140755632:Dinkel, Julien  |d 50000  |e 50000PD140755632  |k 0/50000/  |p 4 
998 |g 1136449035  |a Wroblewski, Jacek  |m 1136449035:Wroblewski, Jacek  |d 50000  |e 50000PW1136449035  |k 0/50000/  |p 3 
998 |g 139999752  |a Wielpütz, Mark Oliver  |m 139999752:Wielpütz, Mark Oliver  |d 910000  |d 911400  |e 910000PW139999752  |e 911400PW139999752  |k 0/910000/  |k 1/910000/911400/  |p 1  |x j 
999 |a KXP-PPN1776305434  |e 3999551356 
BIB |a Y 
SER |a journal 
JSO |a {"name":{"displayForm":["Mark O. Wielpütz, Mathieu Lederlin, Jacek Wroblewski, Julien Dinkel, Monika Eichinger, Jürgen Biederer, Hans-Ulrich Kauczor, Michael Puderbach"]},"id":{"doi":["10.1016/j.ejrad.2013.04.035"],"eki":["1776305434"]},"origin":[{"dateIssuedKey":"2013","dateIssuedDisp":"31 May 2013"}],"person":[{"display":"Wielpütz, Mark Oliver","given":"Mark Oliver","role":"aut","family":"Wielpütz"},{"display":"Lederlin, Mathieu","role":"aut","given":"Mathieu","family":"Lederlin"},{"family":"Wroblewski","role":"aut","given":"Jacek","display":"Wroblewski, Jacek"},{"display":"Dinkel, Julien","family":"Dinkel","role":"aut","given":"Julien"},{"family":"Eichinger","role":"aut","given":"Monika","display":"Eichinger, Monika"},{"display":"Biederer, Jürgen","family":"Biederer","given":"Jürgen","role":"aut"},{"family":"Kauczor","given":"Hans-Ulrich","role":"aut","display":"Kauczor, Hans-Ulrich"},{"display":"Puderbach, Michael","family":"Puderbach","given":"Michael","role":"aut"}],"relHost":[{"title":[{"title_sort":"European journal of radiology","title":"European journal of radiology","subtitle":"EJR"}],"language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"note":["Gesehen am 05.02.20"],"origin":[{"publisher":"Elsevier Science","dateIssuedKey":"1990","dateIssuedDisp":"1990-","publisherPlace":"Amsterdam [u.a.]"}],"disp":"CT volumetry of artificial pulmonary nodules using an ex vivo lung phantom influence of exposure parameters and iterative reconstruction on reproducibilityEuropean journal of radiology","recId":"32044483X","physDesc":[{"extent":"Online-Ressource"}],"id":{"eki":["32044483X"],"issn":["1872-7727"],"zdb":["2005350-2"]},"part":{"pages":"1577-1583","issue":"9","extent":"7","text":"82(2013), 9, Seite 1577-1583","year":"2013","volume":"82"},"titleAlt":[{"title":"EJR"}],"pubHistory":["Nachgewiesen 10.1990 -"]}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"note":["Gesehen am 08.11.2021"],"title":[{"title_sort":"CT volumetry of artificial pulmonary nodules using an ex vivo lung phantom","title":"CT volumetry of artificial pulmonary nodules using an ex vivo lung phantom","subtitle":"influence of exposure parameters and iterative reconstruction on reproducibility"}],"physDesc":[{"extent":"7 S."}],"recId":"1776305434"} 
SRT |a WIELPUETZMCTVOLUMETR3120