Preloaded injectors used in a clinical study: videographic assessment and laboratory analysis of injector nozzle damage

Purpose: To evaluate quality and duration of implantation of 2 preloaded intraocular lens (IOL) injectors and assess postimplantation damage.Setting: The David J. Apple Center for Vision Research, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany. Design: Prospective, random...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Khoramnia, Ramin (VerfasserIn) , Yildirim, Timur Mert (VerfasserIn) , Weindler, Jan N. (VerfasserIn) , Naujokaitis, Tadas (VerfasserIn) , Dzhambazova, Mariyana (VerfasserIn) , Auffarth, Gerd U. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2021
In: Journal of cataract and refractive surgery
Year: 2021, Jahrgang: 47, Heft: 10, Pages: 1338-1344
ISSN:1873-4502
DOI:10.1097/j.jcrs.0000000000000587
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1097/j.jcrs.0000000000000587
Verlag, lizenzpflichtig, Volltext: https://journals.lww.com/jcrs/Fulltext/2021/10000/Preloaded_injectors_used_in_a_clinical_study_.17.aspx
Volltext
Verfasserangaben:Ramin Khoramnia, Timur M. Yildirim, Jan Weindler, Tadas Naujokaitis, Mariyana Dzhambazova, Gerd U. Auffarth

MARC

LEADER 00000caa a2200000 c 4500
001 1777171288
003 DE-627
005 20240414193547.0
007 cr uuu---uuuuu
008 211110s2021 xx |||||o 00| ||eng c
024 7 |a 10.1097/j.jcrs.0000000000000587  |2 doi 
035 |a (DE-627)1777171288 
035 |a (DE-599)KXP1777171288 
035 |a (OCoLC)1341423926 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Khoramnia, Ramin  |d 1980-  |e VerfasserIn  |0 (DE-588)132573954  |0 (DE-627)523957173  |0 (DE-576)299234355  |4 aut 
245 1 0 |a Preloaded injectors used in a clinical study  |b videographic assessment and laboratory analysis of injector nozzle damage  |c Ramin Khoramnia, Timur M. Yildirim, Jan Weindler, Tadas Naujokaitis, Mariyana Dzhambazova, Gerd U. Auffarth 
264 1 |c 2021 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 10.11.2021 
520 |a Purpose: To evaluate quality and duration of implantation of 2 preloaded intraocular lens (IOL) injectors and assess postimplantation damage.Setting: The David J. Apple Center for Vision Research, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany. Design: Prospective, randomized, comparative study with laboratory investigation. Methods: Implantation videos and postuse injectors from 60 paired eyes of 30 bilateral cataract patients were included. Patient eyes were randomly assigned for implantation with 2 different preloaded injectors: the AutonoMe with a Clareon IOL (Alcon Laboratories, Inc.) and the iSert with a Vivinex IOL (Hoya Corp.). Videos were reviewed for events during the implantation procedure, and the duration of each step of implantation. Injector nozzles were examined under light and scanning electron microscopy. Damage was graded and correlated with the IOL power. Three months postoperatively IOLs were assessed for material changes. Results: IOL delivery was without any critical events in 60 of the 60 eyes. The implantation took 56 seconds with the AutonoMe and 44 seconds with the iSert (P < .05). Most AutonoMe injectors (29; 97%) showed no damage or slight deformation. In most of the iSert injectors (25; 80%), short or extended cracks were present, and damage lengths correlated with the IOL power. All IOLs were free of material changes, including glistenings, 3 months postoperatively. Conclusions: Both preloaded IOL injectors allowed a safe and convenient IOL delivery. Implantation of the Clareon IOL took, on average, slightly longer than that of the Vivinex IOL, mostly due to a slower IOL unfolding. The AutonoMe showed less nozzle tip damage than that of the iSert. 
700 1 |a Yildirim, Timur Mert  |d 1990-  |e VerfasserIn  |0 (DE-588)112972557X  |0 (DE-627)88437422X  |0 (DE-576)486529894  |4 aut 
700 1 |a Weindler, Jan N.  |d 1992-  |e VerfasserIn  |0 (DE-588)120866543X  |0 (DE-627)1695019644  |4 aut 
700 1 |a Naujokaitis, Tadas  |e VerfasserIn  |0 (DE-588)1240859635  |0 (DE-627)1769941541  |4 aut 
700 1 |a Dzhambazova, Mariyana  |e VerfasserIn  |4 aut 
700 1 |a Auffarth, Gerd U.  |d 1964-  |e VerfasserIn  |0 (DE-588)123385261  |0 (DE-627)577130420  |0 (DE-576)293687277  |4 aut 
773 0 8 |i Enthalten in  |t Journal of cataract and refractive surgery  |d Hagerstown, MD : Wolters Kluwer Health, 1986  |g 47(2021), 10, Seite 1338-1344  |h Online-Ressource  |w (DE-627)320594203  |w (DE-600)2019330-0  |w (DE-576)260773891  |x 1873-4502  |7 nnas  |a Preloaded injectors used in a clinical study videographic assessment and laboratory analysis of injector nozzle damage 
773 1 8 |g volume:47  |g year:2021  |g number:10  |g pages:1338-1344  |g extent:7  |a Preloaded injectors used in a clinical study videographic assessment and laboratory analysis of injector nozzle damage 
856 4 0 |u https://doi.org/10.1097/j.jcrs.0000000000000587  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://journals.lww.com/jcrs/Fulltext/2021/10000/Preloaded_injectors_used_in_a_clinical_study_.17.aspx  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20211110 
993 |a Article 
994 |a 2021 
998 |g 123385261  |a Auffarth, Gerd U.  |m 123385261:Auffarth, Gerd U.  |d 910000  |d 910900  |e 910000PA123385261  |e 910900PA123385261  |k 0/910000/  |k 1/910000/910900/  |p 6  |y j 
998 |g 1240859635  |a Naujokaitis, Tadas  |m 1240859635:Naujokaitis, Tadas  |d 910000  |d 910900  |e 910000PN1240859635  |e 910900PN1240859635  |k 0/910000/  |k 1/910000/910900/  |p 4 
998 |g 120866543X  |a Weindler, Jan N.  |m 120866543X:Weindler, Jan N.  |d 910000  |d 910900  |e 910000PW120866543X  |e 910900PW120866543X  |k 0/910000/  |k 1/910000/910900/  |p 3 
998 |g 112972557X  |a Yildirim, Timur Mert  |m 112972557X:Yildirim, Timur Mert  |d 910000  |d 910900  |e 910000PY112972557X  |e 910900PY112972557X  |k 0/910000/  |k 1/910000/910900/  |p 2 
998 |g 132573954  |a Khoramnia, Ramin  |m 132573954:Khoramnia, Ramin  |d 910000  |d 910900  |d 50000  |e 910000PK132573954  |e 910900PK132573954  |e 50000PK132573954  |k 0/910000/  |k 1/910000/910900/  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN1777171288  |e 400135571X 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"recId":"320594203","physDesc":[{"extent":"Online-Ressource"}],"note":["Gesehen am 02.08.24"],"titleAlt":[{"title":"Journal of cataract & refractive surgery"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng"],"pubHistory":["12.1986 -"],"part":{"issue":"10","extent":"7","volume":"47","year":"2021","text":"47(2021), 10, Seite 1338-1344","pages":"1338-1344"},"id":{"zdb":["2019330-0"],"issn":["1873-4502"],"eki":["320594203"]},"origin":[{"dateIssuedDisp":"2020-","dateIssuedKey":"2020","publisherPlace":"Hagerstown, MD ; Fairfax, Va ; Amsterdam [u.a.]","publisher":"Wolters Kluwer Health ; American Society of Cataract and Refractive Surgery ; Elsevier"}],"name":{"displayForm":["American Society of Cataract and Refractive Surgery"]},"title":[{"title":"Journal of cataract and refractive surgery","title_sort":"Journal of cataract and refractive surgery"}],"disp":"Preloaded injectors used in a clinical study videographic assessment and laboratory analysis of injector nozzle damageJournal of cataract and refractive surgery"}],"recId":"1777171288","physDesc":[{"extent":"7 S."}],"language":["eng"],"note":["Gesehen am 10.11.2021"],"person":[{"given":"Ramin","role":"aut","display":"Khoramnia, Ramin","family":"Khoramnia"},{"given":"Timur Mert","role":"aut","display":"Yildirim, Timur Mert","family":"Yildirim"},{"display":"Weindler, Jan N.","role":"aut","family":"Weindler","given":"Jan N."},{"family":"Naujokaitis","display":"Naujokaitis, Tadas","role":"aut","given":"Tadas"},{"display":"Dzhambazova, Mariyana","role":"aut","family":"Dzhambazova","given":"Mariyana"},{"family":"Auffarth","role":"aut","display":"Auffarth, Gerd U.","given":"Gerd U."}],"id":{"eki":["1777171288"],"doi":["10.1097/j.jcrs.0000000000000587"]},"origin":[{"dateIssuedKey":"2021","dateIssuedDisp":"2021"}],"name":{"displayForm":["Ramin Khoramnia, Timur M. Yildirim, Jan Weindler, Tadas Naujokaitis, Mariyana Dzhambazova, Gerd U. Auffarth"]},"title":[{"title":"Preloaded injectors used in a clinical study","title_sort":"Preloaded injectors used in a clinical study","subtitle":"videographic assessment and laboratory analysis of injector nozzle damage"}],"type":{"bibl":"article-journal","media":"Online-Ressource"}} 
SRT |a KHORAMNIARPRELOADEDI2021