Cement debonding behaviors of the various tibial components of the ATTUNE knee system and its predecessors: us a cement-in-cement revision an alternative?
Background - Aseptic loosening remains one of the most common causes of revision of the tibial component for total knee arthroplasty. A stable bond between implant and cement is essential for appropriate long-term results. The aim of our in vitro study was to investigate the maximum failure load of...
Saved in:
| Main Authors: | , , , , , |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
9 October 2021
|
| In: |
The knee
Year: 2021, Volume: 33, Pages: 185-192 |
| ISSN: | 1873-5800 |
| DOI: | 10.1016/j.knee.2021.09.010 |
| Online Access: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.knee.2021.09.010 Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0968016021002301 |
| Author Notes: | Sebastian Jaeger, Marvin Eissler, Martin Schwarze, Mareike Schonhoff, Jan Philippe Kretzer, Rudi G. Bitsch |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1778251285 | ||
| 003 | DE-627 | ||
| 005 | 20240415193203.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 211122s2021 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.knee.2021.09.010 |2 doi | |
| 035 | |a (DE-627)1778251285 | ||
| 035 | |a (DE-599)KXP1778251285 | ||
| 035 | |a (OCoLC)1341430899 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Jäger, Sebastian |d 1975- |e VerfasserIn |0 (DE-588)1059313731 |0 (DE-627)79828238X |0 (DE-576)415306647 |4 aut | |
| 245 | 1 | 0 | |a Cement debonding behaviors of the various tibial components of the ATTUNE knee system and its predecessors |b us a cement-in-cement revision an alternative? |c Sebastian Jaeger, Marvin Eissler, Martin Schwarze, Mareike Schonhoff, Jan Philippe Kretzer, Rudi G. Bitsch |
| 264 | 1 | |c 9 October 2021 | |
| 300 | |a 8 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 22.11.2021 | ||
| 520 | |a Background - Aseptic loosening remains one of the most common causes of revision of the tibial component for total knee arthroplasty. A stable bond between implant and cement is essential for appropriate long-term results. The aim of our in vitro study was to investigate the maximum failure load of tibial ATTUNE prosthesis design alternatives compared with a previous design. In addition, cement-in-cement revision was considered as a potential strategy after tibial component debonding. - Methods - The experimental investigations of the maximum failure load of the implant-cement interface were performed under optimal conditions, without potential contamination. We compared the designs of the tibial components of the ATTUNE, ATTUNE S+ and P.F.C. Sigma. In addition, we investigated the cement-in-cement revision for the ATTUNE knee system replacing it with an ATTUNE S+. - Results - The maximum failure load showed no significant difference between P.F.C. Sigma and ATTUNE groups (P = 0.087), but there was a significant difference between the P.F.C. Sigma and the ATTUNE S+ groups (P < 0.001). The analysis also showed a significant difference (P < 0.001) between the ATTUNE and the ATTUNE S+ groups for the maximum failure load. The ATTUNE S+ cement-in-cement revision group showed a significant higher failure load (P < 0.001) compared with the P.F.C. Sigma and ATTUNE groups. No significant differences (P = 1.000) were found between the ATTUNE S+ cement-in-cement and ATTUNE S+ group. - Conclusion - Based on these results, we found no design-specific evidence of increased debonding risk with the ATTUNE and ATTUNE S+ components compared with the P.F.C Sigma. Furthermore, the cement-in-cement revision seems to be an alternative for the revision surgery. | ||
| 650 | 4 | |a ATTUNE | |
| 650 | 4 | |a Cement debonding | |
| 650 | 4 | |a Cement-in-cement revision | |
| 650 | 4 | |a Implant stability | |
| 650 | 4 | |a P.F.C. Sigma | |
| 700 | 1 | |a Eissler, Marvin |d 1994- |e VerfasserIn |0 (DE-588)1246230380 |0 (DE-627)1778250270 |4 aut | |
| 700 | 1 | |a Schwarze, Martin |d 1986- |e VerfasserIn |0 (DE-588)1081740426 |0 (DE-627)846708663 |0 (DE-576)45474482X |4 aut | |
| 700 | 1 | |a Schonhoff, Mareike |e VerfasserIn |0 (DE-588)120821747X |0 (DE-627)1694427137 |4 aut | |
| 700 | 1 | |a Kretzer, Jan Philippe |d 1978- |e VerfasserIn |0 (DE-588)136998348 |0 (DE-627)589003690 |0 (DE-576)301383103 |4 aut | |
| 700 | 1 | |a Bitsch, Rudi G. |d 1970- |e VerfasserIn |0 (DE-588)131490060 |0 (DE-627)50981378X |0 (DE-576)298541726 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t The knee |d Amsterdam [u.a.] : Elsevier Science, 1994 |g 33(2021), Seite 185-192 |h Online-Ressource |w (DE-627)320466965 |w (DE-600)2008020-7 |w (DE-576)264423755 |x 1873-5800 |7 nnas |a Cement debonding behaviors of the various tibial components of the ATTUNE knee system and its predecessors us a cement-in-cement revision an alternative? |
| 773 | 1 | 8 | |g volume:33 |g year:2021 |g pages:185-192 |g extent:8 |a Cement debonding behaviors of the various tibial components of the ATTUNE knee system and its predecessors us a cement-in-cement revision an alternative? |
| 856 | 4 | 0 | |u https://doi.org/10.1016/j.knee.2021.09.010 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://www.sciencedirect.com/science/article/pii/S0968016021002301 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20211122 | ||
| 993 | |a Article | ||
| 994 | |a 2021 | ||
| 998 | |g 131490060 |a Bitsch, Rudi G. |m 131490060:Bitsch, Rudi G. |d 50000 |e 50000PB131490060 |k 0/50000/ |p 6 |y j | ||
| 998 | |g 136998348 |a Kretzer, Jan Philippe |m 136998348:Kretzer, Jan Philippe |d 910000 |d 911460 |d 50000 |e 910000PK136998348 |e 911460PK136998348 |e 50000PK136998348 |k 0/910000/ |k 1/910000/911460/ |k 0/50000/ |p 5 | ||
| 998 | |g 120821747X |a Schonhoff, Mareike |m 120821747X:Schonhoff, Mareike |d 910000 |d 911460 |e 910000PS120821747X |e 911460PS120821747X |k 0/910000/ |k 1/910000/911460/ |p 4 | ||
| 998 | |g 1081740426 |a Schwarze, Martin |m 1081740426:Schwarze, Martin |d 910000 |d 911460 |e 910000PS1081740426 |e 911460PS1081740426 |k 0/910000/ |k 1/910000/911460/ |p 3 | ||
| 998 | |g 1246230380 |a Eissler, Marvin |m 1246230380:Eissler, Marvin |d 910000 |d 911400 |e 910000PE1246230380 |e 911400PE1246230380 |k 0/910000/ |k 1/910000/911400/ |p 2 | ||
| 998 | |g 1059313731 |a Jäger, Sebastian |m 1059313731:Jäger, Sebastian |d 910000 |d 911460 |e 910000PJ1059313731 |e 911460PJ1059313731 |k 0/910000/ |k 1/910000/911460/ |p 1 |x j | ||
| 999 | |a KXP-PPN1778251285 |e 4004714532 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"origin":[{"dateIssuedKey":"2021","dateIssuedDisp":"9 October 2021"}],"language":["eng"],"note":["Gesehen am 22.11.2021"],"relHost":[{"id":{"eki":["320466965"],"zdb":["2008020-7"],"issn":["1873-5800"]},"recId":"320466965","pubHistory":["1.1994 -"],"origin":[{"publisher":"Elsevier Science","dateIssuedDisp":"1994-","publisherPlace":"Amsterdam [u.a.]","dateIssuedKey":"1994"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"part":{"volume":"33","text":"33(2021), Seite 185-192","extent":"8","year":"2021","pages":"185-192"},"physDesc":[{"extent":"Online-Ressource"}],"note":["Gesehen am 22.09.2021"],"language":["eng"],"disp":"Cement debonding behaviors of the various tibial components of the ATTUNE knee system and its predecessors us a cement-in-cement revision an alternative?The knee","title":[{"title":"The knee","title_sort":"knee"}]}],"physDesc":[{"extent":"8 S."}],"name":{"displayForm":["Sebastian Jaeger, Marvin Eissler, Martin Schwarze, Mareike Schonhoff, Jan Philippe Kretzer, Rudi G. Bitsch"]},"id":{"doi":["10.1016/j.knee.2021.09.010"],"eki":["1778251285"]},"recId":"1778251285","title":[{"subtitle":"us a cement-in-cement revision an alternative?","title":"Cement debonding behaviors of the various tibial components of the ATTUNE knee system and its predecessors","title_sort":"Cement debonding behaviors of the various tibial components of the ATTUNE knee system and its predecessors"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"person":[{"role":"aut","given":"Sebastian","roleDisplay":"VerfasserIn","display":"Jäger, Sebastian","family":"Jäger"},{"role":"aut","family":"Eissler","roleDisplay":"VerfasserIn","given":"Marvin","display":"Eissler, Marvin"},{"role":"aut","given":"Martin","roleDisplay":"VerfasserIn","display":"Schwarze, Martin","family":"Schwarze"},{"role":"aut","given":"Mareike","roleDisplay":"VerfasserIn","display":"Schonhoff, Mareike","family":"Schonhoff"},{"role":"aut","family":"Kretzer","display":"Kretzer, Jan Philippe","roleDisplay":"VerfasserIn","given":"Jan Philippe"},{"family":"Bitsch","roleDisplay":"VerfasserIn","display":"Bitsch, Rudi G.","given":"Rudi G.","role":"aut"}]} | ||
| SRT | |a JAEGERSEBACEMENTDEBO9202 | ||