Pupil dynamics after in-the-bag versus anterior and retropupillary iris-fixated intraocular lens implantation

An Intraocular Lens (IOL) fixated on the iris either anteriorly, as a phakic IOL, or posteriorly, as an aphakic IOL, can influence pupil motility. In this interventional case series study, we evaluated pupil size under different levels of illumination (scotopic = 0.04 lx, low-mesopic = 0.4 lx and hi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Sun, Yanxiu (VerfasserIn) , Hammer, Maximilian (VerfasserIn) , Yildirim, Timur Mert (VerfasserIn) , Khoramnia, Ramin (VerfasserIn) , Auffarth, Gerd U. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 02 November 2021
In: Scientific reports
Year: 2021, Jahrgang: 11, Pages: 1-8
ISSN:2045-2322
DOI:10.1038/s41598-021-01051-6
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.1038/s41598-021-01051-6
Verlag, kostenfrei, Volltext: https://www.nature.com/articles/s41598-021-01051-6
Volltext
Verfasserangaben:Yanxiu Sun, Maximilian Hammer, Timur M. Yildirim, Ramin Khoramnia & Gerd U. Auffarth

MARC

LEADER 00000caa a2200000 c 4500
001 1779959362
003 DE-627
005 20240415193238.0
007 cr uuu---uuuuu
008 211201s2021 xx |||||o 00| ||eng c
024 7 |a 10.1038/s41598-021-01051-6  |2 doi 
035 |a (DE-627)1779959362 
035 |a (DE-599)KXP1779959362 
035 |a (OCoLC)1341434526 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Sun, Yanxiu  |d 1973-  |e VerfasserIn  |0 (DE-588)1077075340  |0 (DE-627)835964795  |0 (DE-576)44593574X  |4 aut 
245 1 0 |a Pupil dynamics after in-the-bag versus anterior and retropupillary iris-fixated intraocular lens implantation  |c Yanxiu Sun, Maximilian Hammer, Timur M. Yildirim, Ramin Khoramnia & Gerd U. Auffarth 
264 1 |c 02 November 2021 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 01.12.2021 
520 |a An Intraocular Lens (IOL) fixated on the iris either anteriorly, as a phakic IOL, or posteriorly, as an aphakic IOL, can influence pupil motility. In this interventional case series study, we evaluated pupil size under different levels of illumination (scotopic = 0.04 lx, low-mesopic = 0.4 lx and high-mesopic = 4 lx) for anterior iris-claw IOL fixation for correcting myopia or hyperopia (IFPH), retropupillary iris-claw IOL fixation to correct aphakia or as treatment for late in-the-bag IOL dislocation/subluxation (IFRP), and capsular-fixation IOL in-the-bag implantation (IB). Pupil size was measured preoperatively for the IFPH- and IB-group as well as 6 months after surgery for all groups. We analyzed a total of 70 eyes: 22 eyes of 11 patients with phakic IOLs, 22 eyes of 20 patients in the IFRP group and 26 eyes of 13 patients in the IB group. Both IFPH and IB showed a smaller postoperative scotopic pupil size, compared with the preoperative values. When compared to postoperative values of IB and IFPH, IFRP showed a significantly smaller postoperative scotopic pupil size (IFPH: 5.89 ± 0.83 mm, IFRP: 4.37 ± 0.83 mm, IB: 5.34 ± 0.98 mm, p < 0.001) while no differences were seen at high-mesopic lighting. Neither of the surgical techniques seems to impair the constriction of the pupil. 
650 4 |a Eye diseases 
650 4 |a Lens diseases 
650 4 |a Pupil disorders 
700 1 |a Hammer, Maximilian  |d 1997-  |e VerfasserIn  |0 (DE-588)1237104750  |0 (DE-627)1763009041  |4 aut 
700 1 |a Yildirim, Timur Mert  |d 1990-  |e VerfasserIn  |0 (DE-588)112972557X  |0 (DE-627)88437422X  |0 (DE-576)486529894  |4 aut 
700 1 |a Khoramnia, Ramin  |d 1980-  |e VerfasserIn  |0 (DE-588)132573954  |0 (DE-627)523957173  |0 (DE-576)299234355  |4 aut 
700 1 |a Auffarth, Gerd U.  |d 1964-  |e VerfasserIn  |0 (DE-588)123385261  |0 (DE-627)577130420  |0 (DE-576)293687277  |4 aut 
773 0 8 |i Enthalten in  |t Scientific reports  |d [London] : Springer Nature, 2011  |g 11(2021), Artikel-ID 21436, Seite 1-8  |h Online-Ressource  |w (DE-627)663366712  |w (DE-600)2615211-3  |w (DE-576)346641179  |x 2045-2322  |7 nnas  |a Pupil dynamics after in-the-bag versus anterior and retropupillary iris-fixated intraocular lens implantation 
773 1 8 |g volume:11  |g year:2021  |g elocationid:21436  |g pages:1-8  |g extent:8  |a Pupil dynamics after in-the-bag versus anterior and retropupillary iris-fixated intraocular lens implantation 
856 4 0 |u https://doi.org/10.1038/s41598-021-01051-6  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://www.nature.com/articles/s41598-021-01051-6  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20211201 
993 |a Article 
994 |a 2021 
998 |g 123385261  |a Auffarth, Gerd U.  |m 123385261:Auffarth, Gerd U.  |d 910000  |d 910900  |e 910000PA123385261  |e 910900PA123385261  |k 0/910000/  |k 1/910000/910900/  |p 5  |y j 
998 |g 132573954  |a Khoramnia, Ramin  |m 132573954:Khoramnia, Ramin  |d 910000  |d 910900  |d 50000  |e 910000PK132573954  |e 910900PK132573954  |e 50000PK132573954  |k 0/910000/  |k 1/910000/910900/  |k 0/50000/  |p 4 
998 |g 112972557X  |a Yildirim, Timur Mert  |m 112972557X:Yildirim, Timur Mert  |d 910000  |d 910900  |e 910000PY112972557X  |e 910900PY112972557X  |k 0/910000/  |k 1/910000/910900/  |p 3 
998 |g 1237104750  |a Hammer, Maximilian  |m 1237104750:Hammer, Maximilian  |d 50000  |e 50000PH1237104750  |k 0/50000/  |p 2 
999 |a KXP-PPN1779959362  |e 4010625503 
BIB |a Y 
SER |a journal 
JSO |a {"person":[{"role":"aut","family":"Sun","given":"Yanxiu","display":"Sun, Yanxiu"},{"display":"Hammer, Maximilian","given":"Maximilian","family":"Hammer","role":"aut"},{"display":"Yildirim, Timur Mert","given":"Timur Mert","family":"Yildirim","role":"aut"},{"role":"aut","family":"Khoramnia","given":"Ramin","display":"Khoramnia, Ramin"},{"display":"Auffarth, Gerd U.","given":"Gerd U.","family":"Auffarth","role":"aut"}],"title":[{"title_sort":"Pupil dynamics after in-the-bag versus anterior and retropupillary iris-fixated intraocular lens implantation","title":"Pupil dynamics after in-the-bag versus anterior and retropupillary iris-fixated intraocular lens implantation"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"origin":[{"dateIssuedDisp":"02 November 2021","dateIssuedKey":"2021"}],"note":["Gesehen am 01.12.2021"],"recId":"1779959362","id":{"doi":["10.1038/s41598-021-01051-6"],"eki":["1779959362"]},"relHost":[{"note":["Gesehen am 12.07.24"],"origin":[{"dateIssuedKey":"2011","dateIssuedDisp":"2011-","publisher":"Springer Nature ; Nature Publishing Group","publisherPlace":"[London] ; London"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"pubHistory":["1, article number 1 (2011)-"],"title":[{"title_sort":"Scientific reports","title":"Scientific reports"}],"language":["eng"],"part":{"volume":"11","pages":"1-8","extent":"8","year":"2021","text":"11(2021), Artikel-ID 21436, Seite 1-8"},"physDesc":[{"extent":"Online-Ressource"}],"disp":"Pupil dynamics after in-the-bag versus anterior and retropupillary iris-fixated intraocular lens implantationScientific reports","recId":"663366712","id":{"issn":["2045-2322"],"zdb":["2615211-3"],"eki":["663366712"]}}],"name":{"displayForm":["Yanxiu Sun, Maximilian Hammer, Timur M. Yildirim, Ramin Khoramnia & Gerd U. Auffarth"]},"physDesc":[{"extent":"8 S."}],"language":["eng"]} 
SRT |a SUNYANXIUHPUPILDYNAM0220