A multicentre, randomized clinical trial comparing the Veriset haemostatic patch with fibrin sealant for the management of bleeding during hepatic surgery

Background - Bleeding during hepatic surgery is associated with prolonged hospitalization and increased morbidity and mortality. The Veriset™ haemostatic patch is a topical haemostat comprised of an absorbable backing made of oxidized cellulose and self‐adhesive hydrogel components. It is designed t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Öllinger, Robert (VerfasserIn) , Mihaljevic, Andre L. (VerfasserIn) , Schuhmacher, Christoph (VerfasserIn) , Bektas, Hüseyin (VerfasserIn) , Vondran, Florian (VerfasserIn) , Kleine, Moritz (VerfasserIn) , Sainz‐Barriga, Mauricio (VerfasserIn) , Weiss, Sascha (VerfasserIn) , Knebel, Phillip (VerfasserIn) , Pratschke, Johann (VerfasserIn) , Troisi, Roberto I. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2013
In: HPB
Year: 2013, Jahrgang: 15, Heft: 7, Pages: 548-558
ISSN:1477-2574
DOI:10.1111/hpb.12009
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1111/hpb.12009
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S1365182X1531426X
Volltext
Verfasserangaben:Robert Öllinger, Andre L. Mihaljevic, Christoph Schuhmacher, Hüseyin Bektas, Florian Vondran, Moritz Kleine, Mauricio Sainz‐Barriga, Sascha Weiss, Phillip Knebel, Johann Pratschke & Roberto I. Troisi
Beschreibung
Zusammenfassung:Background - Bleeding during hepatic surgery is associated with prolonged hospitalization and increased morbidity and mortality. The Veriset™ haemostatic patch is a topical haemostat comprised of an absorbable backing made of oxidized cellulose and self‐adhesive hydrogel components. It is designed to achieve haemostasis quickly and adhere to tissues without fixation. - Methods - A prospective, randomized, multicentre, single‐blinded study (n = 50) was performed to compare the use of a Veriset™ haemostatic patch with a fibrin sealant patch (TachoSil®) (control) in the management of diffuse bleeding after hepatic surgery. Patients were randomized following the confirmation of diffuse bleeding requiring the use of a topical haemostat. Time to haemostasis was assessed at preset intervals until haemostasis was achieved. - Results - Both groups were similar in comorbidities and procedural techniques. The median time to haemostasis in the group using the Veriset™ haemostatic patch was 1.0 min compared with 3.0 min in the control group (P < 0.001; 3‐min minimum application time for the control patch). This result was independent of bleeding severity and surface area. Both products had similar safety profiles and no statistical differences were observed in the occurrence of adverse or device‐related events. - Conclusions - Regardless of bleeding severity or surface area, the Veriset™ haemostatic patch achieved haemostasis in this setting significantly faster than the control device in patients undergoing hepatic resection. It was safe and easy to handle in open hepatic surgery.
Beschreibung:Elektronische Reproduktion der Druck-Ausgabe
Available online 16 December 2015
Gesehen am 06.12.2021
Beschreibung:Online Resource
ISSN:1477-2574
DOI:10.1111/hpb.12009