Experimental comparison of proton CT and dual energy x-ray CT for relative stopping power estimation in proton therapy

Proton computed tomography (pCT) has been proposed as an alternative to x-ray computed tomography (CT) for acquiring relative to water stopping power (RSP) maps used for proton treatment planning dose calculations. In parallel, it has been shown that dual energy x-ray CT (DECT) improves RSP accuracy...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Dedes, George (VerfasserIn) , Dickmann, Jannis (VerfasserIn) , Niepel, Katharina (VerfasserIn) , Wesp, Philipp (VerfasserIn) , Johnson, Robert P. (VerfasserIn) , Pankuch, Mark (VerfasserIn) , Bashkirov, Vladimir (VerfasserIn) , Rit, Simon (VerfasserIn) , Volz, Lennart (VerfasserIn) , Schulte, Reinhard W. (VerfasserIn) , Landry, Guillaume (VerfasserIn) , Parodi, Katia (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 14 August 2019
In: Physics in medicine and biology
Year: 2019, Jahrgang: 64, Heft: 16, Pages: 1-16
ISSN:1361-6560
DOI:10.1088/1361-6560/ab2b72
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1088/1361-6560/ab2b72
Volltext
Verfasserangaben:George Dedes, Jannis Dickmann, Katharina Niepel, Philipp Wesp, Robert P. Johnson, Mark Pankuch, Vladimir Bashkirov, Simon Rit, Lennart Volz, Reinhard W. Schulte, Guillaume Landry, and Katia Parodi

MARC

LEADER 00000caa a2200000 c 4500
001 178040395X
003 DE-627
005 20230427104217.0
007 cr uuu---uuuuu
008 211206s2019 xx |||||o 00| ||eng c
024 7 |a 10.1088/1361-6560/ab2b72  |2 doi 
035 |a (DE-627)178040395X 
035 |a (DE-599)KXP178040395X 
035 |a (OCoLC)1341434710 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 29  |2 sdnb 
100 1 |a Dedes, George  |e VerfasserIn  |0 (DE-588)1246989255  |0 (DE-627)1780403437  |4 aut 
245 1 0 |a Experimental comparison of proton CT and dual energy x-ray CT for relative stopping power estimation in proton therapy  |c George Dedes, Jannis Dickmann, Katharina Niepel, Philipp Wesp, Robert P. Johnson, Mark Pankuch, Vladimir Bashkirov, Simon Rit, Lennart Volz, Reinhard W. Schulte, Guillaume Landry, and Katia Parodi 
264 1 |c 14 August 2019 
300 |a 16 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 06.12.2021 
520 |a Proton computed tomography (pCT) has been proposed as an alternative to x-ray computed tomography (CT) for acquiring relative to water stopping power (RSP) maps used for proton treatment planning dose calculations. In parallel, it has been shown that dual energy x-ray CT (DECT) improves RSP accuracy when compared to conventional single energy x-ray CT. This study aimed at directly comparing the RSP accuracy of both modalities using phantoms scanned at an advanced prototype pCT scanner and a state-of-the-art DECT scanner. Two phantoms containing 13 tissue-mimicking inserts of known RSP were scanned at the pCT phase II prototype and a latest generation dual-source DECT scanner (Siemens SOMATOM Definition FORCE). RSP accuracy was compared by mean absolute percent error (MAPE) over all inserts. A highly realistic Monte Carlo (MC) simulation was used to gain insight on pCT image artifacts which degraded MAPE. MAPE was 0.55% for pCT and 0.67% for DECT. The realistic MC simulation agreed well with pCT measurements (). Both simulation and experimental results showed ring artifacts in pCT images which degraded the MAPE compared to an ideal pCT simulation (). Using the realistic simulation, we could identify sources of artifacts, which are attributed to the interfaces in the five-stage plastic scintillator energy detector and calibration curve interpolation regions. Secondary artifacts stemming from the proton tracker geometry were also identified. The pCT prototype scanner outperformed a state-of-the-art DECT scanner in terms of RSP accuracy (MAPE) for plastic tissue mimicking inserts. Since artifacts tended to concentrate in the inserts, their mitigation may lead to further improvements in the reported pCT accuracy. 
700 1 |a Dickmann, Jannis  |d 1993-  |e VerfasserIn  |0 (DE-588)1234592290  |0 (DE-627)1759438758  |4 aut 
700 1 |a Niepel, Katharina  |e VerfasserIn  |4 aut 
700 1 |a Wesp, Philipp  |e VerfasserIn  |4 aut 
700 1 |a Johnson, Robert P.  |e VerfasserIn  |4 aut 
700 1 |a Pankuch, Mark  |e VerfasserIn  |4 aut 
700 1 |a Bashkirov, Vladimir  |e VerfasserIn  |4 aut 
700 1 |a Rit, Simon  |e VerfasserIn  |4 aut 
700 1 |a Volz, Lennart  |d 1992-  |e VerfasserIn  |0 (DE-588)1164508121  |0 (DE-627)1028942141  |0 (DE-576)510057004  |4 aut 
700 1 |a Schulte, Reinhard W.  |e VerfasserIn  |4 aut 
700 1 |a Landry, Guillaume  |e VerfasserIn  |4 aut 
700 1 |a Parodi, Katia  |d 1975-  |e VerfasserIn  |0 (DE-588)129736996  |0 (DE-627)707308917  |0 (DE-576)188641688  |4 aut 
773 0 8 |i Enthalten in  |t Physics in medicine and biology  |d Bristol : IOP Publ., 1956  |g 64(2019), 16, Artikel-ID 165002, Seite 1-16  |h Online-Ressource  |w (DE-627)269016163  |w (DE-600)1473501-5  |w (DE-576)088704130  |x 1361-6560  |7 nnas  |a Experimental comparison of proton CT and dual energy x-ray CT for relative stopping power estimation in proton therapy 
773 1 8 |g volume:64  |g year:2019  |g number:16  |g elocationid:165002  |g pages:1-16  |g extent:16  |a Experimental comparison of proton CT and dual energy x-ray CT for relative stopping power estimation in proton therapy 
856 4 0 |u https://doi.org/10.1088/1361-6560/ab2b72  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20211206 
993 |a Article 
994 |a 2019 
998 |g 1164508121  |a Volz, Lennart  |m 1164508121:Volz, Lennart  |d 130000  |e 130000PV1164508121  |k 0/130000/  |p 9 
999 |a KXP-PPN178040395X  |e 4014613275 
BIB |a Y 
SER |a journal 
JSO |a {"type":{"media":"Online-Ressource","bibl":"article-journal"},"name":{"displayForm":["George Dedes, Jannis Dickmann, Katharina Niepel, Philipp Wesp, Robert P. Johnson, Mark Pankuch, Vladimir Bashkirov, Simon Rit, Lennart Volz, Reinhard W. Schulte, Guillaume Landry, and Katia Parodi"]},"language":["eng"],"id":{"eki":["178040395X"],"doi":["10.1088/1361-6560/ab2b72"]},"physDesc":[{"extent":"16 S."}],"title":[{"title":"Experimental comparison of proton CT and dual energy x-ray CT for relative stopping power estimation in proton therapy","title_sort":"Experimental comparison of proton CT and dual energy x-ray CT for relative stopping power estimation in proton therapy"}],"person":[{"given":"George","display":"Dedes, George","role":"aut","family":"Dedes"},{"family":"Dickmann","role":"aut","display":"Dickmann, Jannis","given":"Jannis"},{"family":"Niepel","given":"Katharina","display":"Niepel, Katharina","role":"aut"},{"role":"aut","given":"Philipp","display":"Wesp, Philipp","family":"Wesp"},{"role":"aut","display":"Johnson, Robert P.","given":"Robert P.","family":"Johnson"},{"given":"Mark","display":"Pankuch, Mark","role":"aut","family":"Pankuch"},{"role":"aut","given":"Vladimir","display":"Bashkirov, Vladimir","family":"Bashkirov"},{"role":"aut","given":"Simon","display":"Rit, Simon","family":"Rit"},{"family":"Volz","role":"aut","display":"Volz, Lennart","given":"Lennart"},{"given":"Reinhard W.","display":"Schulte, Reinhard W.","role":"aut","family":"Schulte"},{"family":"Landry","role":"aut","given":"Guillaume","display":"Landry, Guillaume"},{"role":"aut","display":"Parodi, Katia","given":"Katia","family":"Parodi"}],"note":["Gesehen am 06.12.2021"],"origin":[{"dateIssuedDisp":"14 August 2019","dateIssuedKey":"2019"}],"relHost":[{"disp":"Experimental comparison of proton CT and dual energy x-ray CT for relative stopping power estimation in proton therapyPhysics in medicine and biology","physDesc":[{"extent":"Online-Ressource"}],"part":{"extent":"16","volume":"64","issue":"16","pages":"1-16","year":"2019","text":"64(2019), 16, Artikel-ID 165002, Seite 1-16"},"title":[{"title_sort":"Physics in medicine and biology","subtitle":"an official journal of the Institute of Physics and Engineering in Medicine","title":"Physics in medicine and biology"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"id":{"eki":["269016163"],"zdb":["1473501-5"],"issn":["1361-6560"]},"language":["eng"],"recId":"269016163","pubHistory":["1.1956 -"],"note":["Gesehen am 28.01.2019","Fortsetzung der Druck-Ausgabe"],"origin":[{"publisherPlace":"Bristol","publisher":"IOP Publ.","dateIssuedDisp":"1956-","dateIssuedKey":"1956"}]}],"recId":"178040395X"} 
SRT |a DEDESGEORGEXPERIMENT1420