Biomechanical Influences on mesh-related complications in incisional hernia repair

Aim: Hernia repair strengthens the abdominal wall with a textile mesh. Recurrence and pain indicate weak bonds between mesh and tissue. It remains a question which biomechanical factors strengthen the mesh-tissue interface, and whether surgeons can enhance the bond between mesh and tissue. Material...

Full description

Saved in:
Bibliographic Details
Main Authors: Kallinowski, Friedrich (Author) , Ludwig, Yannique (Author) , Gutjahr, Dominik (Author) , Gerhard, Christian (Author) , Schulte-Hörmann, Hannah (Author) , Krimmel, Lena (Author) , Lesch, Carolin (Author) , Uhr, Katharina (Author) , Lösel, Philipp (Author) , Voß, Samuel (Author) , Heuveline, Vincent (Author) , Vollmer, Matthias (Author) , Görich, Johannes (Author) , Nessel, Regine (Author)
Corporate Authors: Technische Universität Hamburg (Other) , Technische Universität Hamburg, Institute of Biomechanics (Other)
Format: Article (Journal)
Language:English
Published: 2021
In: Frontiers in Surgery
Year: 2021, Volume: 8, Pages: 1-16
ISSN:2296-875X
DOI:10.3389/fsurg.2021.763957
Online Access:Resolving-System: https://doi.org/10.3389/fsurg.2021.763957
Resolving-System, kostenfrei: http://nbn-resolving.de/urn:nbn:de:gbv:830-882.0160296
Resolving-System, kostenfrei, Volltext: https://doi.org/10.15480/882.3933
Resolving-System, kostenfrei: http://hdl.handle.net/11420/11062
Get full text
Author Notes:Friedrich Kallinowski, Yannique Ludwig, Dominik Gutjahr, Christian Gerhard, Hannah Schulte-Hörmann, Lena Krimmel, Carolin Lesch, Katharina Uhr, Philipp Lösel, Samuel Voß, Vincent Heuveline, Matthias Vollmer, Johannes Görich and Regine Nessel

MARC

LEADER 00000caa a2200000 c 4500
001 178093422X
003 DE-627
005 20240508084618.0
007 cr uuu---uuuuu
008 211210s2021 xx |||||o 00| ||eng c
024 7 |a urn:nbn:de:gbv:830-882.0160296  |2 urn 
024 7 |a 10.3389/fsurg.2021.763957  |2 doi 
024 7 |a 10.15480/882.3933  |2 doi 
024 7 |a 11420/11062  |2 hdl 
035 |a (DE-627)178093422X 
035 |a (DE-599)KXP178093422X 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
082 0 |a 600: Technik 
082 0 |a 610: Medizin 
084 |a 33  |2 sdnb 
100 1 |a Kallinowski, Friedrich  |d 1959-  |e VerfasserIn  |0 (DE-588)1043912606  |0 (DE-627)77104254X  |0 (DE-576)396018661  |4 aut 
245 1 0 |a Biomechanical Influences on mesh-related complications in incisional hernia repair  |c Friedrich Kallinowski, Yannique Ludwig, Dominik Gutjahr, Christian Gerhard, Hannah Schulte-Hörmann, Lena Krimmel, Carolin Lesch, Katharina Uhr, Philipp Lösel, Samuel Voß, Vincent Heuveline, Matthias Vollmer, Johannes Görich and Regine Nessel 
264 1 |c 2021 
300 |b Illustrationen, Diagramme 
300 |a 16 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Sonstige Körperschaft: Technische Universität Hamburg 
500 |a Sonstige Körperschaft: Technische Universität Hamburg, Institute of Biomechanics 
506 0 |q DE-830  |a Open Access  |e Controlled Vocabulary for Access Rights  |u http://purl.org/coar/access_right/c_abf2 
520 |a Aim: Hernia repair strengthens the abdominal wall with a textile mesh. Recurrence and pain indicate weak bonds between mesh and tissue. It remains a question which biomechanical factors strengthen the mesh-tissue interface, and whether surgeons can enhance the bond between mesh and tissue. Material and Methods: This study assessed the strength of the mesh-tissue interface by dynamic loads. A self-built bench test delivered dynamic impacts. The test simulated coughing. Porcine and bovine tissue were used for the bench test. Tissue quality, mesh adhesiveness, and fixation intensity influenced the retention power. The influences were condensed in a formula to assess the durability of the repair. The formula was applied to clinical work. The relative strength of reconstruction was related to the individual human abdominal wall. From computerized tomography at rest and during Valsalva's Maneuver, the tissue quality of the individual patient was determined before surgery. Results: The results showed that biomechanical parameters observed in porcine, bovine, and human tissue were in the same range. Tissues failed in distinct patterns. Sutures slackened or burst at vulnerable points. Both the load duration and the peak load increased destruction. Stress concentrations elevated failure rates. Regional areas of force contortions increased stress concentrations. Hernia repair improved strain levels. Measures for improvement included the closure of the defect, use of higher dynamic intermittent strain (DIS) class meshes, increased mesh overlap, and additional fixation. Surgeons chose the safety margin of the reconstruction as desired. Conclusion: The tissue quality has now been introduced into the concept of a critical and a gained resistance toward pressure-related impacts. A durable hernia repair could be designed from available coefficients. Using biomechanical principles, surgeons could minimize pain levels. Mesh-related complications such as hernia recurrence can potentially be avoided in incisional hernia repair. 
540 |q DE-830  |a Namensnennung 4.0 International  |f CC BY 4.0  |2 cc  |u https://creativecommons.org/licenses/by/4.0/ 
650 7 |a bench test  |2 DSpace 
650 7 |a computerized tomography  |2 DSpace 
650 7 |a CRIP  |2 DSpace 
650 7 |a GRIP  |2 DSpace 
650 7 |a hernia repair  |2 DSpace 
650 7 |a incisional hernia  |2 DSpace 
700 1 |a Ludwig, Yannique  |e VerfasserIn  |0 (DE-588)1233691244  |0 (DE-627)1758048816  |4 aut 
700 1 |a Gutjahr, Dominik  |d 1992-  |e VerfasserIn  |0 (DE-588)1233638491  |0 (DE-627)1757949364  |4 aut 
700 1 |a Gerhard, Christian  |e VerfasserIn  |0 (DE-588)1248140303  |0 (DE-627)1782657762  |4 aut 
700 1 |a Schulte-Hörmann, Hannah  |e VerfasserIn  |4 aut 
700 1 |a Krimmel, Lena  |e VerfasserIn  |4 aut 
700 1 |a Lesch, Carolin  |e VerfasserIn  |0 (DE-588)1315045559  |0 (DE-627)187728128X  |4 aut 
700 1 |a Uhr, Katharina  |d 1996-  |e VerfasserIn  |0 (DE-588)132138095X  |0 (DE-627)1881477304  |4 aut 
700 1 |a Lösel, Philipp  |d 1986-  |e VerfasserIn  |0 (DE-588)1147623414  |0 (DE-627)1008687596  |0 (DE-576)495916528  |4 aut 
700 1 |a Voß, Samuel  |d 1989-  |e VerfasserIn  |0 (DE-588)123593554X  |0 (DE-627)1761181408  |4 aut 
700 1 |a Heuveline, Vincent  |d 1968-  |e VerfasserIn  |0 (DE-588)1046579266  |0 (DE-627)776691880  |0 (DE-576)399904727  |4 aut 
700 1 |a Vollmer, Matthias  |e VerfasserIn  |0 (DE-588)1185525327  |0 (DE-627)1664870792  |4 aut 
700 1 |a Görich, Johannes  |d 1958-  |e VerfasserIn  |0 (DE-588)132866760X  |0 (DE-627)1888095105  |4 aut 
700 1 |a Nessel, Regine  |e VerfasserIn  |4 aut 
710 2 |a Technische Universität Hamburg  |0 (DE-588)1112763473  |0 (DE-627)866918418  |0 (DE-576)476770564  |4 oth 
710 2 |a Technische Universität Hamburg  |b Institute of Biomechanics  |0 (DE-588)1168636493  |0 (DE-627)1032410434  |0 (DE-576)511662963  |4 oth 
773 0 8 |i Enthalten in  |t Frontiers in Surgery  |d Lausanne : Frontiers Media, 2014  |g 8(2021) vom: 29. Okt., Artikel-ID 763957, Seite 1-16  |h Online-Ressource  |w (DE-627)788288954  |w (DE-600)2773823-1  |w (DE-576)408066717  |x 2296-875X  |7 nnas  |a Biomechanical Influences on mesh-related complications in incisional hernia repair 
773 1 8 |g volume:8  |g year:2021  |g day:29  |g month:10  |g elocationid:763957  |g pages:1-16  |g extent:16  |a Biomechanical Influences on mesh-related complications in incisional hernia repair 
856 4 0 |u https://doi.org/10.3389/fsurg.2021.763957  |x Resolving-System  |x Verlag 
856 4 0 |u http://nbn-resolving.de/urn:nbn:de:gbv:830-882.0160296  |x Resolving-System  |z kostenfrei 
856 4 0 |u https://doi.org/10.15480/882.3933  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u http://hdl.handle.net/11420/11062  |x Resolving-System  |z kostenfrei 
935 |i DSpace 
951 |a AR 
992 |a 20211221 
993 |a Article 
994 |a 2021 
998 |g 1046579266  |a Heuveline, Vincent  |m 1046579266:Heuveline, Vincent  |d 700000  |d 708000  |e 700000PH1046579266  |e 708000PH1046579266  |k 0/700000/  |k 1/700000/708000/  |p 11 
998 |g 1147623414  |a Lösel, Philipp  |m 1147623414:Lösel, Philipp  |d 700000  |d 708000  |e 700000PL1147623414  |e 708000PL1147623414  |k 0/700000/  |k 1/700000/708000/  |p 9 
998 |g 132138095X  |a Uhr, Katharina  |m 132138095X:Uhr, Katharina  |d 50000  |e 50000PU132138095X  |k 0/50000/  |p 8 
998 |g 1315045559  |a Lesch, Carolin  |m 1315045559:Lesch, Carolin  |d 50000  |e 50000PL1315045559  |k 0/50000/  |p 7 
998 |g 1248140303  |a Gerhard, Christian  |m 1248140303:Gerhard, Christian  |d 50000  |e 50000PG1248140303  |k 0/50000/  |p 4 
998 |g 1233691244  |a Ludwig, Yannique  |m 1233691244:Ludwig, Yannique  |d 50000  |e 50000PL1233691244  |k 0/50000/  |p 2 
998 |g 1043912606  |a Kallinowski, Friedrich  |m 1043912606:Kallinowski, Friedrich  |d 910000  |d 910200  |d 50000  |e 910000PK1043912606  |e 910200PK1043912606  |e 50000PK1043912606  |k 0/910000/  |k 1/910000/910200/  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN178093422X  |e 4023507660 
BIB |a Y 
SER |a journal 
JSO |a {"title":[{"title_sort":"Biomechanical Influences on mesh-related complications in incisional hernia repair","title":"Biomechanical Influences on mesh-related complications in incisional hernia repair"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"corporate":[{"display":"Technische Universität Hamburg","role":"oth"},{"role":"oth","display":"Technische Universität Hamburg"}],"id":{"uri":["urn:nbn:de:gbv:830-882.0160296"],"doi":["10.3389/fsurg.2021.763957","10.15480/882.3933"],"hdl":["11420/11062"],"eki":["178093422X"]},"physDesc":[{"noteIll":"Illustrationen, Diagramme","extent":"16 S."}],"relHost":[{"disp":"Biomechanical Influences on mesh-related complications in incisional hernia repairFrontiers in Surgery","type":{"media":"Online-Ressource","bibl":"periodical"},"titleAlt":[{"title":"FSURG"},{"title":"Front. Surg."}],"language":["eng"],"part":{"year":"2021","volume":"8","text":"8(2021) vom: 29. Okt., Artikel-ID 763957, Seite 1-16","pages":"1-16","extent":"16"},"pubHistory":["1.2014 -"],"title":[{"title":"Frontiers in Surgery","title_sort":"Frontiers in Surgery"}],"physDesc":[{"extent":"Online-Ressource"}],"id":{"zdb":["2773823-1"],"eki":["788288954"],"issn":["2296-875X"]},"origin":[{"publisher":"Frontiers Media","dateIssuedDisp":"2014-","dateIssuedKey":"2014","publisherPlace":"Lausanne"}],"recId":"788288954"}],"origin":[{"dateIssuedKey":"2021","dateIssuedDisp":"2021"}],"language":["eng"],"name":{"displayForm":["Friedrich Kallinowski, Yannique Ludwig, Dominik Gutjahr, Christian Gerhard, Hannah Schulte-Hörmann, Lena Krimmel, Carolin Lesch, Katharina Uhr, Philipp Lösel, Samuel Voß, Vincent Heuveline, Matthias Vollmer, Johannes Görich and Regine Nessel"]},"person":[{"role":"aut","family":"Kallinowski","given":"Friedrich","display":"Kallinowski, Friedrich"},{"given":"Yannique","display":"Ludwig, Yannique","role":"aut","family":"Ludwig"},{"role":"aut","family":"Gutjahr","given":"Dominik","display":"Gutjahr, Dominik"},{"role":"aut","family":"Gerhard","given":"Christian","display":"Gerhard, Christian"},{"family":"Schulte-Hörmann","role":"aut","display":"Schulte-Hörmann, Hannah","given":"Hannah"},{"display":"Krimmel, Lena","given":"Lena","family":"Krimmel","role":"aut"},{"given":"Carolin","display":"Lesch, Carolin","family":"Lesch","role":"aut"},{"family":"Uhr","role":"aut","display":"Uhr, Katharina","given":"Katharina"},{"family":"Lösel","role":"aut","display":"Lösel, Philipp","given":"Philipp"},{"role":"aut","family":"Voß","given":"Samuel","display":"Voß, Samuel"},{"given":"Vincent","display":"Heuveline, Vincent","role":"aut","family":"Heuveline"},{"given":"Matthias","display":"Vollmer, Matthias","family":"Vollmer","role":"aut"},{"role":"aut","family":"Görich","display":"Görich, Johannes","given":"Johannes"},{"given":"Regine","display":"Nessel, Regine","family":"Nessel","role":"aut"}],"recId":"178093422X","note":["Sonstige Körperschaft: Technische Universität Hamburg","Sonstige Körperschaft: Technische Universität Hamburg, Institute of Biomechanics"]} 
SRT |a KALLINOWSKBIOMECHANI2021