The influence of haemodialysis on haemodynamic measurements using transpulmonary thermodilution in patients with septic shock: an observational study

Context: Patients with sepsis frequently present with acute renal failure requiring intermittent renal replacement therapy and haemodynamic monitoring. To date, the effect of haemodialysis on PiCCO monitoring has not been determined. - Objective: To determine the effect of haemodialysis on the measu...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Pathil-Warth, Anita (VerfasserIn) , Stremmel, Wolfgang (VerfasserIn) , Schwenger, Vedat (VerfasserIn) , Eisenbach, Christoph (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2013
In: European journal of anaesthesiology
Year: 2013, Jahrgang: 30, Heft: 1, Pages: 16-20
ISSN:1365-2346
DOI:10.1097/EJA.0b013e328358543a
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1097/EJA.0b013e328358543a
Verlag, lizenzpflichtig, Volltext: https://journals.lww.com/ejanaesthesiology/Fulltext/2013/01000/The_influence_of_haemodialysis_on_haemodynamic.5.aspx
Volltext
Verfasserangaben:Anita Pathil, Wolfgang Stremmel, Vedat Schwenger and Christoph Eisenbach

MARC

LEADER 00000caa a2200000 c 4500
001 1782586296
003 DE-627
005 20220820095930.0
007 cr uuu---uuuuu
008 211220s2013 xx |||||o 00| ||eng c
024 7 |a 10.1097/EJA.0b013e328358543a  |2 doi 
035 |a (DE-627)1782586296 
035 |a (DE-599)KXP1782586296 
035 |a (OCoLC)1341436521 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Pathil-Warth, Anita  |d 1981-  |e VerfasserIn  |0 (DE-588)132644304  |0 (DE-627)524715890  |0 (DE-576)260118915  |4 aut 
245 1 4 |a The influence of haemodialysis on haemodynamic measurements using transpulmonary thermodilution in patients with septic shock  |b an observational study  |c Anita Pathil, Wolfgang Stremmel, Vedat Schwenger and Christoph Eisenbach 
264 1 |c 2013 
300 |a 5 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Published online 29 August 2012 
500 |a Gesehen am 20.12.2021 
520 |a Context: Patients with sepsis frequently present with acute renal failure requiring intermittent renal replacement therapy and haemodynamic monitoring. To date, the effect of haemodialysis on PiCCO monitoring has not been determined. - Objective: To determine the effect of haemodialysis on the measurement of haemodynamic variables using transpulmonary thermodilution. - Design: Prospective observational study. - Setting: Medical ICU in a university hospital. - Patients: Thirty patients with sepsis and acute renal failure undergoing intermittent haemodialysis. - Interventions: None. - Main outcome measures: Cardiac index, global end-diastolic volume index and extravascular lung water index measured with or without haemodialysis. - Results: Significant correlations were found for all variables measured with and without haemodialysis (r = 0.55 to 0.91, P < 0.01). Measurements of cardiac index without and with haemodialysis were significantly different [4.71 vs. 4.18 l min−1 m−2, difference −0.54 (SD 0.70), 95% confidence interval (CI) −0.80 to −0.28; P < 0.01], as were values of global end-diastolic volume index without and with haemodialysis [864.8 vs. 775.3 ml m−2, difference −89.5 (SD 191.8), 95% CI −161.2 to −17.9; P = 0.02]. Measurements of extravascular lung water index without and with haemodialysis did not differ significantly [10.3 vs. 10.0 ml kg−1, difference −0.3 (SD 2.0), 95% CI −1.1 to 0.5; P = 0.42]. - Conclusion: Although significant correlations were found for cardiac index, global end-diastolic volume index and extravascular lung water index with and without haemodialysis, cardiac index and global end-diastolic volume index were significantly reduced during haemodialysis, but not extravascular lung water index, when measured by the PiCCO system in patients with septic shock. Although differences were small, the variability of within-patient differences may be clinically important and care should be taken in relying solely on such measurements. 
700 1 |a Stremmel, Wolfgang  |d 1952-  |e VerfasserIn  |0 (DE-588)142773638  |0 (DE-627)640118747  |0 (DE-576)33331560X  |4 aut 
700 1 |a Schwenger, Vedat  |e VerfasserIn  |0 (DE-588)1022867652  |0 (DE-627)717320197  |0 (DE-576)176592237  |4 aut 
700 1 |a Eisenbach, Christoph  |e VerfasserIn  |0 (DE-588)1022807560  |0 (DE-627)71704419X  |0 (DE-576)366008579  |4 aut 
773 0 8 |i Enthalten in  |t European journal of anaesthesiology  |d Philadelphia, Pa. : Lippincott Williams & Wilkins, 1996  |g 30(2013), 1, Seite 16-20  |h Online-Ressource  |w (DE-627)320441350  |w (DE-600)2004964-X  |w (DE-576)09095467X  |x 1365-2346  |7 nnas  |a The influence of haemodialysis on haemodynamic measurements using transpulmonary thermodilution in patients with septic shock an observational study 
773 1 8 |g volume:30  |g year:2013  |g number:1  |g pages:16-20  |g extent:5  |a The influence of haemodialysis on haemodynamic measurements using transpulmonary thermodilution in patients with septic shock an observational study 
856 4 0 |u https://doi.org/10.1097/EJA.0b013e328358543a  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://journals.lww.com/ejanaesthesiology/Fulltext/2013/01000/The_influence_of_haemodialysis_on_haemodynamic.5.aspx  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20211220 
993 |a Article 
994 |a 2013 
998 |g 1022807560  |a Eisenbach, Christoph  |m 1022807560:Eisenbach, Christoph  |d 910000  |d 910100  |e 910000PE1022807560  |e 910100PE1022807560  |k 0/910000/  |k 1/910000/910100/  |p 4  |y j 
998 |g 1022867652  |a Schwenger, Vedat  |m 1022867652:Schwenger, Vedat  |d 50000  |e 50000PS1022867652  |k 0/50000/  |p 3 
998 |g 142773638  |a Stremmel, Wolfgang  |m 142773638:Stremmel, Wolfgang  |d 910000  |d 910100  |e 910000PS142773638  |e 910100PS142773638  |k 0/910000/  |k 1/910000/910100/  |p 2 
998 |g 132644304  |a Pathil-Warth, Anita  |m 132644304:Pathil-Warth, Anita  |d 910000  |d 910100  |e 910000PP132644304  |e 910100PP132644304  |k 0/910000/  |k 1/910000/910100/  |p 1  |x j 
999 |a KXP-PPN1782586296  |e 4022824360 
BIB |a Y 
SER |a journal 
JSO |a {"recId":"1782586296","note":["Published online 29 August 2012","Gesehen am 20.12.2021"],"language":["eng"],"title":[{"title":"The influence of haemodialysis on haemodynamic measurements using transpulmonary thermodilution in patients with septic shock","subtitle":"an observational study","title_sort":"influence of haemodialysis on haemodynamic measurements using transpulmonary thermodilution in patients with septic shock"}],"person":[{"given":"Anita","family":"Pathil-Warth","display":"Pathil-Warth, Anita","roleDisplay":"VerfasserIn","role":"aut"},{"family":"Stremmel","given":"Wolfgang","display":"Stremmel, Wolfgang","role":"aut","roleDisplay":"VerfasserIn"},{"family":"Schwenger","given":"Vedat","display":"Schwenger, Vedat","role":"aut","roleDisplay":"VerfasserIn"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Eisenbach, Christoph","given":"Christoph","family":"Eisenbach"}],"name":{"displayForm":["Anita Pathil, Wolfgang Stremmel, Vedat Schwenger and Christoph Eisenbach"]},"physDesc":[{"extent":"5 S."}],"id":{"doi":["10.1097/EJA.0b013e328358543a"],"eki":["1782586296"]},"origin":[{"dateIssuedKey":"2013","dateIssuedDisp":"2013"}],"relHost":[{"part":{"text":"30(2013), 1, Seite 16-20","issue":"1","year":"2013","pages":"16-20","extent":"5","volume":"30"},"pubHistory":["Nachgewiesen 13.1996,2 -"],"id":{"zdb":["2004964-X"],"doi":["10.1111/(ISSN)1365-2346"],"eki":["320441350"],"issn":["1365-2346"]},"type":{"bibl":"periodical","media":"Online-Ressource"},"origin":[{"dateIssuedKey":"1996","publisherPlace":"Philadelphia, Pa. ; New York, NY ; Riverwoods, Ill. ; London [u.a.] ; Cambridge","publisher":"Lippincott Williams & Wilkins ; Ovid ; Wolters Kluwer Health ; Wiley ; Univ. Pr.","dateIssuedDisp":"1996-"}],"note":["Gesehen am 18.04.2024"],"recId":"320441350","title":[{"subtitle":"EJA","title_sort":"European journal of anaesthesiology","title":"European journal of anaesthesiology"}],"language":["eng"],"name":{"displayForm":["publ. on behalf of the European Academy of Anaesthesiology and the European Society of Anaesthesiologists"]},"physDesc":[{"extent":"Online-Ressource"}],"disp":"The influence of haemodialysis on haemodynamic measurements using transpulmonary thermodilution in patients with septic shock an observational studyEuropean journal of anaesthesiology","titleAlt":[{"title":"EJA"}]}],"type":{"media":"Online-Ressource","bibl":"article-journal"}} 
SRT |a PATHILWARTINFLUENCEO2013