Reliability of brain volumes from multicenter MRI acquisition: a calibration study

Multicenter studies can provide additional information over single center studies because of their increased statistical power. Because similar acquisition protocols are being used internationally for structural magnetic resonance imaging (MRI) studies of the human brain, volumetric MRI data studies...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Schnack, Hugo G. (VerfasserIn) , van Haren, Neeltje E.M. (VerfasserIn) , Hulshoff Pol, Hilleke E. (VerfasserIn) , Picchioni, Marco (VerfasserIn) , Weisbrod, Matthias (VerfasserIn) , Sauer, Heinrich (VerfasserIn) , Cannon, Tyrone (VerfasserIn) , Huttunen, Matti (VerfasserIn) , Murray, Robin (VerfasserIn) , Kahn, René S. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 03 June 2004
In: Human brain mapping
Year: 2004, Jahrgang: 22, Heft: 4, Pages: 312-320
ISSN:1097-0193
DOI:10.1002/hbm.20040
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1002/hbm.20040
Verlag, lizenzpflichtig, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1002/hbm.20040
Volltext
Verfasserangaben:Hugo G. Schnack, Neeltje E.M. van Haren, Hilleke E. Hulshoff Pol, Marco Picchioni, Matthias Weisbrod, Heinrich Sauer, Tyrone Cannon, Matti Huttunen, Robin Murray, René S. Kahn

MARC

LEADER 00000caa a2200000 c 4500
001 1783539569
003 DE-627
005 20230426063032.0
007 cr uuu---uuuuu
008 211223s2004 xx |||||o 00| ||eng c
024 7 |a 10.1002/hbm.20040  |2 doi 
035 |a (DE-627)1783539569 
035 |a (DE-599)KXP1783539569 
035 |a (OCoLC)1341436488 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Schnack, Hugo G.  |e VerfasserIn  |0 (DE-588)1248316177  |0 (DE-627)1783539437  |4 aut 
245 1 0 |a Reliability of brain volumes from multicenter MRI acquisition  |b a calibration study  |c Hugo G. Schnack, Neeltje E.M. van Haren, Hilleke E. Hulshoff Pol, Marco Picchioni, Matthias Weisbrod, Heinrich Sauer, Tyrone Cannon, Matti Huttunen, Robin Murray, René S. Kahn 
264 1 |c 03 June 2004 
300 |a 9 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 23.12.2021 
520 |a Multicenter studies can provide additional information over single center studies because of their increased statistical power. Because similar acquisition protocols are being used internationally for structural magnetic resonance imaging (MRI) studies of the human brain, volumetric MRI data studies seem suitable for this purpose. Possible systematic differences between sites should be avoided, however, particularly when subtle differences in tissue volume are being searched for, such as in neuropsychiatric diseases. In this calibration study, the brains of six healthy volunteers were (re)scanned with MR scanners from four different manufacturers at five different sites, using the local acquisition protocols. The images were segmented at a central reference site. The intraclass correlation coefficient (ICC) was determined for the whole brain, gray and white matter, cerebellum, and lateral and third ventricle volumes. When required, the processing algorithms were calibrated for each site. Calibration of the histogram analysis was needed for segmentation of total brain volume at one site and for gray and white matter volume at all sites. No (additional) calibration was needed for cerebellum and ventricle volumes. The ICCs were ≥0.96 for total brain, ≥0.92 for cerebellum, ≥0.96 for lateral ventricle, ≥0.21 for third ventricle, ≥0.84 for gray matter, and ≥0.78 for white matter volume. Calibration of segmentation procedures allows morphologic MRI data acquired at different research sites to be combined reliably in multicenter studies. Hum. Brain Mapping 22:312-320, 2004. © 2004 Wiley-Liss, Inc. 
650 4 |a brain 
650 4 |a calibration 
650 4 |a MRI 
650 4 |a multicenter 
650 4 |a reliability 
650 4 |a segmentation 
700 1 |a van Haren, Neeltje E.M.  |e VerfasserIn  |4 aut 
700 1 |a Hulshoff Pol, Hilleke E.  |e VerfasserIn  |4 aut 
700 1 |a Picchioni, Marco  |e VerfasserIn  |4 aut 
700 1 |a Weisbrod, Matthias  |d 1960-  |e VerfasserIn  |0 (DE-588)1018045562  |0 (DE-627)690499647  |0 (DE-576)170710211  |4 aut 
700 1 |a Sauer, Heinrich  |d 1948-  |e VerfasserIn  |0 (DE-588)140008500  |0 (DE-627)615228801  |0 (DE-576)314162305  |4 aut 
700 1 |a Cannon, Tyrone  |e VerfasserIn  |4 aut 
700 1 |a Huttunen, Matti  |e VerfasserIn  |4 aut 
700 1 |a Murray, Robin  |e VerfasserIn  |4 aut 
700 1 |a Kahn, René S.  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Human brain mapping  |d New York, NY : Wiley-Liss, 1993  |g 22(2004), 4, Seite 312-320  |h Online-Ressource  |w (DE-627)302922911  |w (DE-600)1492703-2  |w (DE-576)090855248  |x 1097-0193  |7 nnas  |a Reliability of brain volumes from multicenter MRI acquisition a calibration study 
773 1 8 |g volume:22  |g year:2004  |g number:4  |g pages:312-320  |g extent:9  |a Reliability of brain volumes from multicenter MRI acquisition a calibration study 
856 4 0 |u https://doi.org/10.1002/hbm.20040  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://onlinelibrary.wiley.com/doi/abs/10.1002/hbm.20040  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20211223 
993 |a Article 
994 |a 2004 
998 |g 1018045562  |a Weisbrod, Matthias  |m 1018045562:Weisbrod, Matthias  |d 910000  |d 910600  |e 910000PW1018045562  |e 910600PW1018045562  |k 0/910000/  |k 1/910000/910600/  |p 5 
999 |a KXP-PPN1783539569  |e 402639977X 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"origin":[{"dateIssuedDisp":"1993-","publisher":"Wiley-Liss","publisherPlace":"New York, NY","dateIssuedKey":"1993"}],"pubHistory":["1.1993 -"],"title":[{"title_sort":"Human brain mapping","title":"Human brain mapping"}],"part":{"text":"22(2004), 4, Seite 312-320","pages":"312-320","issue":"4","extent":"9","year":"2004","volume":"22"},"language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"Reliability of brain volumes from multicenter MRI acquisition a calibration studyHuman brain mapping","physDesc":[{"extent":"Online-Ressource"}],"note":["Gesehen am 11.10.05"],"id":{"issn":["1097-0193"],"doi":["10.1002/(ISSN)1097-0193"],"eki":["302922911"],"zdb":["1492703-2"]},"recId":"302922911"}],"recId":"1783539569","language":["eng"],"name":{"displayForm":["Hugo G. Schnack, Neeltje E.M. van Haren, Hilleke E. Hulshoff Pol, Marco Picchioni, Matthias Weisbrod, Heinrich Sauer, Tyrone Cannon, Matti Huttunen, Robin Murray, René S. Kahn"]},"note":["Gesehen am 23.12.2021"],"id":{"eki":["1783539569"],"doi":["10.1002/hbm.20040"]},"person":[{"family":"Schnack","display":"Schnack, Hugo G.","given":"Hugo G.","roleDisplay":"VerfasserIn","role":"aut"},{"role":"aut","roleDisplay":"VerfasserIn","given":"Neeltje E.M.","display":"van Haren, Neeltje E.M.","family":"van Haren"},{"given":"Hilleke E.","roleDisplay":"VerfasserIn","role":"aut","family":"Hulshoff Pol","display":"Hulshoff Pol, Hilleke E."},{"given":"Marco","roleDisplay":"VerfasserIn","role":"aut","family":"Picchioni","display":"Picchioni, Marco"},{"role":"aut","given":"Matthias","roleDisplay":"VerfasserIn","family":"Weisbrod","display":"Weisbrod, Matthias"},{"family":"Sauer","display":"Sauer, Heinrich","role":"aut","roleDisplay":"VerfasserIn","given":"Heinrich"},{"family":"Cannon","display":"Cannon, Tyrone","role":"aut","roleDisplay":"VerfasserIn","given":"Tyrone"},{"family":"Huttunen","display":"Huttunen, Matti","given":"Matti","roleDisplay":"VerfasserIn","role":"aut"},{"role":"aut","roleDisplay":"VerfasserIn","given":"Robin","display":"Murray, Robin","family":"Murray"},{"display":"Kahn, René S.","family":"Kahn","role":"aut","roleDisplay":"VerfasserIn","given":"René S."}],"title":[{"title_sort":"Reliability of brain volumes from multicenter MRI acquisition","title":"Reliability of brain volumes from multicenter MRI acquisition","subtitle":"a calibration study"}],"physDesc":[{"extent":"9 S."}],"origin":[{"dateIssuedDisp":"03 June 2004","dateIssuedKey":"2004"}],"type":{"media":"Online-Ressource","bibl":"article-journal"}} 
SRT |a SCHNACKHUGRELIABILIT0320