In vivo accuracy of dental magnetic resonance imaging in assessing maxillary molar furcation involvement: a feasibility study in humans
Aim To investigate the accuracy and reliability of dental magnetic resonance imaging (dMRI) in assessing maxillary molar furcation involvement (FI). Material and Methods In this prospective study, 22 patients with severe periodontitis underwent cone-beam computed tomography (CBCT) and dMRI. For 192...
Gespeichert in:
| Hauptverfasser: | , , , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
2020
|
| In: |
Journal of clinical periodontology
Year: 2020, Jahrgang: 47, Heft: 7, Pages: 809-815 |
| ISSN: | 1600-051X |
| DOI: | 10.1111/jcpe.13299 |
| Online-Zugang: | Verlag, kostenfrei, Volltext: https://doi.org/10.1111/jcpe.13299 Verlag, kostenfrei, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1111/jcpe.13299 |
| Verfasserangaben: | Alexander Juerchott, Meysam Sohani, Franz Sebastian Schwindling, Johann M.E. Jende, Felix T. Kurz, Peter Rammelsberg, Sabine Heiland, Martin Bendszus, Tim Hilgenfeld |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1784859117 | ||
| 003 | DE-627 | ||
| 005 | 20250224162458.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 220105s2020 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1111/jcpe.13299 |2 doi | |
| 035 | |a (DE-627)1784859117 | ||
| 035 | |a (DE-599)KXP1784859117 | ||
| 035 | |a (OCoLC)1295680002 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Jürchott, Alexander |e VerfasserIn |0 (DE-588)1167429230 |0 (DE-627)1031103090 |0 (DE-576)511136137 |4 aut | |
| 245 | 1 | 0 | |a In vivo accuracy of dental magnetic resonance imaging in assessing maxillary molar furcation involvement |b a feasibility study in humans |c Alexander Juerchott, Meysam Sohani, Franz Sebastian Schwindling, Johann M.E. Jende, Felix T. Kurz, Peter Rammelsberg, Sabine Heiland, Martin Bendszus, Tim Hilgenfeld |
| 264 | 1 | |c 2020 | |
| 300 | |a 7 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a First published: 28 April 2020 | ||
| 500 | |a Gesehen am 05.01.2022 | ||
| 520 | |a Aim To investigate the accuracy and reliability of dental magnetic resonance imaging (dMRI) in assessing maxillary molar furcation involvement (FI). Material and Methods In this prospective study, 22 patients with severe periodontitis underwent cone-beam computed tomography (CBCT) and dMRI. For 192 furcation entrances, the degree of horizontal FI was assessed by two independent observers on both modalities. Results of dMRI were compared with CBCT (reference modality) to assess the accuracy of dMRI. Cohen's kappa (κ), sensitivity and specificity were calculated for FI classification. Bland-Altman analysis and the Kruskal-Wallis test were used to evaluate measurement accuracy of dMRI. Results Based on CBCT findings, 93 furcation entrances revealed FI (degree I/II/III: 35/19/39). Intra- and inter-reader agreement was excellent for both modalities (κ-range: 0.884 to 0.933). dMRI measurements showed high agreement with CBCT (bias: 0.17 mm; 95% limits of agreement: −1.05 to 1.38 mm), and measurement accuracy did not differ among different degrees of FI (p = .67). For FI detection, sensitivity and specificity of dMRI were 98% and 99%. For FI classification, sensitivity values of dMRI were 89%/84%/100% for degree I/II/III. Conclusions Compared to CBCT (non-invasive gold standard), dMRI demonstrates high accuracy and reliability in evaluating the degree of FI in maxillary molars. | ||
| 650 | 4 | |a 3D imaging | |
| 650 | 4 | |a cone-beam computed tomography | |
| 650 | 4 | |a furcation involvement | |
| 650 | 4 | |a magnetic resonance imaging | |
| 650 | 4 | |a periodontitis | |
| 700 | 1 | |a Sohani, Meysam |d 1983- |e VerfasserIn |0 (DE-588)1357141505 |0 (DE-627)1917820062 |4 aut | |
| 700 | 1 | |a Schwindling, Franz Sebastian |d 1986- |e VerfasserIn |0 (DE-588)1036843572 |0 (DE-627)751703613 |0 (DE-576)38697926X |4 aut | |
| 700 | 1 | |a Jende, Johann |e VerfasserIn |0 (DE-588)1161484809 |0 (DE-627)1024781569 |0 (DE-576)506571025 |4 aut | |
| 700 | 1 | |a Kurz, Felix T. |d 1981- |e VerfasserIn |0 (DE-588)1043285474 |0 (DE-627)771321066 |0 (DE-576)394610342 |4 aut | |
| 700 | 1 | |a Rammelsberg, Peter |d 1959- |e VerfasserIn |0 (DE-588)122469836 |0 (DE-627)705920836 |0 (DE-576)293285640 |4 aut | |
| 700 | 1 | |a Heiland, Sabine |e VerfasserIn |0 (DE-588)106732626X |0 (DE-627)818624450 |0 (DE-576)426561368 |4 aut | |
| 700 | 1 | |a Bendszus, Martin |e VerfasserIn |0 (DE-588)1032676426 |0 (DE-627)738634131 |0 (DE-576)175567697 |4 aut | |
| 700 | 1 | |a Hilgenfeld, Tim |d 1986- |e VerfasserIn |0 (DE-588)1106261917 |0 (DE-627)862954398 |0 (DE-576)473950316 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Journal of clinical periodontology |d Oxford [u.a.] : Wiley-Blackwell, 1974 |g 47(2020), 7, Seite 809-815 |h Online-Ressource |w (DE-627)323607381 |w (DE-600)2026349-1 |w (DE-576)093888732 |x 1600-051X |7 nnas |a In vivo accuracy of dental magnetic resonance imaging in assessing maxillary molar furcation involvement a feasibility study in humans |
| 773 | 1 | 8 | |g volume:47 |g year:2020 |g number:7 |g pages:809-815 |g extent:7 |a In vivo accuracy of dental magnetic resonance imaging in assessing maxillary molar furcation involvement a feasibility study in humans |
| 856 | 4 | 0 | |u https://doi.org/10.1111/jcpe.13299 |x Verlag |x Resolving-System |z kostenfrei |3 Volltext |
| 856 | 4 | 0 | |u https://onlinelibrary.wiley.com/doi/abs/10.1111/jcpe.13299 |x Verlag |z kostenfrei |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20220105 | ||
| 993 | |a Article | ||
| 994 | |a 2020 | ||
| 998 | |g 1106261917 |a Hilgenfeld, Tim |m 1106261917:Hilgenfeld, Tim |d 910000 |d 911100 |d 50000 |e 910000PH1106261917 |e 911100PH1106261917 |e 50000PH1106261917 |k 0/910000/ |k 1/910000/911100/ |k 0/50000/ |p 9 |y j | ||
| 998 | |g 1032676426 |a Bendszus, Martin |m 1032676426:Bendszus, Martin |d 910000 |d 911100 |e 910000PB1032676426 |e 911100PB1032676426 |k 0/910000/ |k 1/910000/911100/ |p 8 | ||
| 998 | |g 106732626X |a Heiland, Sabine |m 106732626X:Heiland, Sabine |d 910000 |d 911100 |e 910000PH106732626X |e 911100PH106732626X |k 0/910000/ |k 1/910000/911100/ |p 7 | ||
| 998 | |g 122469836 |a Rammelsberg, Peter |m 122469836:Rammelsberg, Peter |d 910000 |d 910800 |e 910000PR122469836 |e 910800PR122469836 |k 0/910000/ |k 1/910000/910800/ |p 6 | ||
| 998 | |g 1043285474 |a Kurz, Felix T. |m 1043285474:Kurz, Felix T. |d 910000 |d 911100 |d 50000 |e 910000PK1043285474 |e 911100PK1043285474 |e 50000PK1043285474 |k 0/910000/ |k 1/910000/911100/ |k 0/50000/ |p 5 | ||
| 998 | |g 1161484809 |a Jende, Johann |m 1161484809:Jende, Johann |d 910000 |d 911100 |e 910000PJ1161484809 |e 911100PJ1161484809 |k 0/910000/ |k 1/910000/911100/ |p 4 | ||
| 998 | |g 1036843572 |a Schwindling, Franz Sebastian |m 1036843572:Schwindling, Franz Sebastian |d 910000 |d 910800 |d 50000 |e 910000PS1036843572 |e 910800PS1036843572 |e 50000PS1036843572 |k 0/910000/ |k 1/910000/910800/ |k 0/50000/ |p 3 | ||
| 998 | |g 1357141505 |a Sohani, Meysam |m 1357141505:Sohani, Meysam |d 50000 |e 50000PS1357141505 |k 0/50000/ |p 2 | ||
| 998 | |g 1167429230 |a Jürchott, Alexander |m 1167429230:Jürchott, Alexander |d 910000 |d 911100 |e 910000PJ1167429230 |e 911100PJ1167429230 |k 0/910000/ |k 1/910000/911100/ |p 1 |x j | ||
| 999 | |a KXP-PPN1784859117 |e 4030309658 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"note":["First published: 28 April 2020","Gesehen am 05.01.2022"],"title":[{"subtitle":"a feasibility study in humans","title":"In vivo accuracy of dental magnetic resonance imaging in assessing maxillary molar furcation involvement","title_sort":"In vivo accuracy of dental magnetic resonance imaging in assessing maxillary molar furcation involvement"}],"origin":[{"dateIssuedKey":"2020","dateIssuedDisp":"2020"}],"relHost":[{"id":{"doi":["10.1111/(ISSN)1600-051X"],"zdb":["2026349-1"],"issn":["1600-051X"],"eki":["323607381"]},"title":[{"title_sort":"Journal of clinical periodontology","title":"Journal of clinical periodontology","subtitle":"the official publication of the European Federation of Periodontology"}],"part":{"extent":"7","text":"47(2020), 7, Seite 809-815","issue":"7","pages":"809-815","volume":"47","year":"2020"},"language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"note":["Gesehen am 08.04.22"],"origin":[{"dateIssuedDisp":"1974-","dateIssuedKey":"1974","publisherPlace":"Oxford [u.a.] ; Copenhagen ; Oxford [u.a.]","publisher":"Wiley-Blackwell ; Munksgaard ; Blackwell"}],"pubHistory":["1.1974 -"],"disp":"In vivo accuracy of dental magnetic resonance imaging in assessing maxillary molar furcation involvement a feasibility study in humansJournal of clinical periodontology","recId":"323607381","physDesc":[{"extent":"Online-Ressource"}]}],"person":[{"role":"aut","given":"Alexander","family":"Jürchott","display":"Jürchott, Alexander"},{"family":"Sohani","role":"aut","given":"Meysam","display":"Sohani, Meysam"},{"given":"Franz Sebastian","role":"aut","family":"Schwindling","display":"Schwindling, Franz Sebastian"},{"display":"Jende, Johann","family":"Jende","role":"aut","given":"Johann"},{"role":"aut","given":"Felix T.","family":"Kurz","display":"Kurz, Felix T."},{"display":"Rammelsberg, Peter","family":"Rammelsberg","given":"Peter","role":"aut"},{"display":"Heiland, Sabine","family":"Heiland","role":"aut","given":"Sabine"},{"role":"aut","given":"Martin","family":"Bendszus","display":"Bendszus, Martin"},{"display":"Hilgenfeld, Tim","given":"Tim","role":"aut","family":"Hilgenfeld"}],"physDesc":[{"extent":"7 S."}],"recId":"1784859117","id":{"doi":["10.1111/jcpe.13299"],"eki":["1784859117"]},"name":{"displayForm":["Alexander Juerchott, Meysam Sohani, Franz Sebastian Schwindling, Johann M.E. Jende, Felix T. Kurz, Peter Rammelsberg, Sabine Heiland, Martin Bendszus, Tim Hilgenfeld"]}} | ||
| SRT | |a JUERCHOTTAINVIVOACCU2020 | ||