Performance of FBK SiPMs coupled to PETA3 read-out ASIC for PET application
In this paper we show the energy and timing resolution performances of FBK SiPMs coupled to the PETA3 ASIC for PET application. We developed a measurement set-up to characterize single SiPMs coupled to scintillator exploiting the detector stack developed within the HYPERImage project. In this way we...
Gespeichert in:
| Hauptverfasser: | , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
2013
|
| In: |
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment
Year: 2013, Jahrgang: 718, Pages: 345-346 |
| ISSN: | 1872-9576 |
| DOI: | 10.1016/j.nima.2012.10.012 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.nima.2012.10.012 Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0168900212011448 |
| Verfasserangaben: | Claudio Piemonte, Alberto Gola, Alessandro Tarolli, Peter Fisher, Michael Ritzert, Volkmar Schulz, Torsten Solf |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1786966840 | ||
| 003 | DE-627 | ||
| 005 | 20220820112841.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 220124s2013 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.nima.2012.10.012 |2 doi | |
| 035 | |a (DE-627)1786966840 | ||
| 035 | |a (DE-599)KXP1786966840 | ||
| 035 | |a (OCoLC)1341438959 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 29 |2 sdnb | ||
| 100 | 1 | |a Piemonte, Claudio |e VerfasserIn |0 (DE-588)1236030583 |0 (DE-627)1761272616 |4 aut | |
| 245 | 1 | 0 | |a Performance of FBK SiPMs coupled to PETA3 read-out ASIC for PET application |c Claudio Piemonte, Alberto Gola, Alessandro Tarolli, Peter Fisher, Michael Ritzert, Volkmar Schulz, Torsten Solf |
| 264 | 1 | |c 2013 | |
| 300 | |a 2 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Available online 12 October 2012 | ||
| 500 | |a Gesehen am 24.01.2022 | ||
| 520 | |a In this paper we show the energy and timing resolution performances of FBK SiPMs coupled to the PETA3 ASIC for PET application. We developed a measurement set-up to characterize single SiPMs coupled to scintillator exploiting the detector stack developed within the HYPERImage project. In this way we are able to characterize the combined SiPM/ASIC performance with the same signal chain (from the sensor to the ASIC board) used in the PET system. We show that using two scintillator detectors, composed of a 3×3×5mm3 LYSO crystal coupled to a 3×3mm2 SiPM, an intra-stack CRT of about 200ps FWHM can be obtained. | ||
| 650 | 4 | |a CRT | |
| 650 | 4 | |a DLED | |
| 650 | 4 | |a SiPM | |
| 700 | 1 | |a Gola, Alberto |e VerfasserIn |4 aut | |
| 700 | 1 | |a Tarolli, Alessandro |e VerfasserIn |4 aut | |
| 700 | 1 | |a Fischer, Peter |d 1961- |e VerfasserIn |0 (DE-588)130634468 |0 (DE-627)707540682 |0 (DE-576)301221553 |4 aut | |
| 700 | 1 | |a Ritzert, Michael |e VerfasserIn |0 (DE-588)1054166102 |0 (DE-627)791117987 |0 (DE-576)41004783X |4 aut | |
| 700 | 1 | |a Schulz, Volkmar |e VerfasserIn |4 aut | |
| 700 | 1 | |a Solf, Torsten |e VerfasserIn |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment |d [Amsterdam] : Elsevier, 1984 |g 718(2013), Seite 345-346 |h Online-Ressource |w (DE-627)266014666 |w (DE-600)1466532-3 |w (DE-576)074959743 |x 1872-9576 |7 nnas |a Performance of FBK SiPMs coupled to PETA3 read-out ASIC for PET application |
| 773 | 1 | 8 | |g volume:718 |g year:2013 |g pages:345-346 |g extent:2 |a Performance of FBK SiPMs coupled to PETA3 read-out ASIC for PET application |
| 856 | 4 | 0 | |u https://doi.org/10.1016/j.nima.2012.10.012 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://www.sciencedirect.com/science/article/pii/S0168900212011448 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20220124 | ||
| 993 | |a Article | ||
| 994 | |a 2013 | ||
| 998 | |g 1054166102 |a Ritzert, Michael |m 1054166102:Ritzert, Michael |d 700000 |d 720000 |e 700000PR1054166102 |e 720000PR1054166102 |k 0/700000/ |k 1/700000/720000/ |p 5 | ||
| 998 | |g 130634468 |a Fischer, Peter |m 130634468:Fischer, Peter |d 700000 |d 720000 |e 700000PF130634468 |e 720000PF130634468 |k 0/700000/ |k 1/700000/720000/ |p 4 | ||
| 999 | |a KXP-PPN1786966840 |e 4042157467 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"name":{"displayForm":["Claudio Piemonte, Alberto Gola, Alessandro Tarolli, Peter Fisher, Michael Ritzert, Volkmar Schulz, Torsten Solf"]},"note":["Available online 12 October 2012","Gesehen am 24.01.2022"],"id":{"eki":["1786966840"],"doi":["10.1016/j.nima.2012.10.012"]},"person":[{"given":"Claudio","roleDisplay":"VerfasserIn","role":"aut","display":"Piemonte, Claudio","family":"Piemonte"},{"given":"Alberto","display":"Gola, Alberto","roleDisplay":"VerfasserIn","role":"aut","family":"Gola"},{"family":"Tarolli","display":"Tarolli, Alessandro","roleDisplay":"VerfasserIn","role":"aut","given":"Alessandro"},{"family":"Fischer","display":"Fischer, Peter","roleDisplay":"VerfasserIn","role":"aut","given":"Peter"},{"display":"Ritzert, Michael","role":"aut","roleDisplay":"VerfasserIn","given":"Michael","family":"Ritzert"},{"family":"Schulz","display":"Schulz, Volkmar","role":"aut","roleDisplay":"VerfasserIn","given":"Volkmar"},{"given":"Torsten","role":"aut","roleDisplay":"VerfasserIn","display":"Solf, Torsten","family":"Solf"}],"title":[{"title_sort":"Performance of FBK SiPMs coupled to PETA3 read-out ASIC for PET application","title":"Performance of FBK SiPMs coupled to PETA3 read-out ASIC for PET application"}],"relHost":[{"part":{"pages":"345-346","text":"718(2013), Seite 345-346","year":"2013","extent":"2","volume":"718"},"id":{"zdb":["1466532-3"],"eki":["266014666"],"issn":["1872-9576"]},"note":["Gesehen am 24.05.23"],"titleAlt":[{"title":"Nuclear instruments & methods in physics research / A"}],"disp":"Performance of FBK SiPMs coupled to PETA3 read-out ASIC for PET applicationNuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment","origin":[{"publisher":"Elsevier ; North-Holland Publ. Co.","dateIssuedKey":"1994","publisherPlace":"[Amsterdam] ; Amsterdam","dateIssuedDisp":"1994-"}],"physDesc":[{"extent":"Online-Ressource"}],"pubHistory":["Nachgewiesen 226.1984 -"],"type":{"media":"Online-Ressource","bibl":"periodical"},"language":["eng"],"title":[{"title":"Nuclear instruments & methods in physics research","partname":"Accelerators, spectrometers, detectors and associated equipment","subtitle":"a journal on accelerators, instrumentation and techniques applied to research in nuclear and atomic physics, materials science and related fields in physics","title_sort":"Nuclear instruments & methods in physics research"}],"recId":"266014666"}],"recId":"1786966840","type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"origin":[{"dateIssuedKey":"2013","dateIssuedDisp":"2013"}],"physDesc":[{"extent":"2 S."}]} | ||
| SRT | |a PIEMONTECLPERFORMANC2013 | ||