Performance of FBK SiPMs coupled to PETA3 read-out ASIC for PET application

In this paper we show the energy and timing resolution performances of FBK SiPMs coupled to the PETA3 ASIC for PET application. We developed a measurement set-up to characterize single SiPMs coupled to scintillator exploiting the detector stack developed within the HYPERImage project. In this way we...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Piemonte, Claudio (VerfasserIn) , Gola, Alberto (VerfasserIn) , Tarolli, Alessandro (VerfasserIn) , Fischer, Peter (VerfasserIn) , Ritzert, Michael (VerfasserIn) , Schulz, Volkmar (VerfasserIn) , Solf, Torsten (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2013
In: Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment
Year: 2013, Jahrgang: 718, Pages: 345-346
ISSN:1872-9576
DOI:10.1016/j.nima.2012.10.012
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.nima.2012.10.012
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0168900212011448
Volltext
Verfasserangaben:Claudio Piemonte, Alberto Gola, Alessandro Tarolli, Peter Fisher, Michael Ritzert, Volkmar Schulz, Torsten Solf

MARC

LEADER 00000caa a2200000 c 4500
001 1786966840
003 DE-627
005 20220820112841.0
007 cr uuu---uuuuu
008 220124s2013 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.nima.2012.10.012  |2 doi 
035 |a (DE-627)1786966840 
035 |a (DE-599)KXP1786966840 
035 |a (OCoLC)1341438959 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 29  |2 sdnb 
100 1 |a Piemonte, Claudio  |e VerfasserIn  |0 (DE-588)1236030583  |0 (DE-627)1761272616  |4 aut 
245 1 0 |a Performance of FBK SiPMs coupled to PETA3 read-out ASIC for PET application  |c Claudio Piemonte, Alberto Gola, Alessandro Tarolli, Peter Fisher, Michael Ritzert, Volkmar Schulz, Torsten Solf 
264 1 |c 2013 
300 |a 2 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Available online 12 October 2012 
500 |a Gesehen am 24.01.2022 
520 |a In this paper we show the energy and timing resolution performances of FBK SiPMs coupled to the PETA3 ASIC for PET application. We developed a measurement set-up to characterize single SiPMs coupled to scintillator exploiting the detector stack developed within the HYPERImage project. In this way we are able to characterize the combined SiPM/ASIC performance with the same signal chain (from the sensor to the ASIC board) used in the PET system. We show that using two scintillator detectors, composed of a 3×3×5mm3 LYSO crystal coupled to a 3×3mm2 SiPM, an intra-stack CRT of about 200ps FWHM can be obtained. 
650 4 |a CRT 
650 4 |a DLED 
650 4 |a SiPM 
700 1 |a Gola, Alberto  |e VerfasserIn  |4 aut 
700 1 |a Tarolli, Alessandro  |e VerfasserIn  |4 aut 
700 1 |a Fischer, Peter  |d 1961-  |e VerfasserIn  |0 (DE-588)130634468  |0 (DE-627)707540682  |0 (DE-576)301221553  |4 aut 
700 1 |a Ritzert, Michael  |e VerfasserIn  |0 (DE-588)1054166102  |0 (DE-627)791117987  |0 (DE-576)41004783X  |4 aut 
700 1 |a Schulz, Volkmar  |e VerfasserIn  |4 aut 
700 1 |a Solf, Torsten  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment  |d [Amsterdam] : Elsevier, 1984  |g 718(2013), Seite 345-346  |h Online-Ressource  |w (DE-627)266014666  |w (DE-600)1466532-3  |w (DE-576)074959743  |x 1872-9576  |7 nnas  |a Performance of FBK SiPMs coupled to PETA3 read-out ASIC for PET application 
773 1 8 |g volume:718  |g year:2013  |g pages:345-346  |g extent:2  |a Performance of FBK SiPMs coupled to PETA3 read-out ASIC for PET application 
856 4 0 |u https://doi.org/10.1016/j.nima.2012.10.012  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0168900212011448  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20220124 
993 |a Article 
994 |a 2013 
998 |g 1054166102  |a Ritzert, Michael  |m 1054166102:Ritzert, Michael  |d 700000  |d 720000  |e 700000PR1054166102  |e 720000PR1054166102  |k 0/700000/  |k 1/700000/720000/  |p 5 
998 |g 130634468  |a Fischer, Peter  |m 130634468:Fischer, Peter  |d 700000  |d 720000  |e 700000PF130634468  |e 720000PF130634468  |k 0/700000/  |k 1/700000/720000/  |p 4 
999 |a KXP-PPN1786966840  |e 4042157467 
BIB |a Y 
SER |a journal 
JSO |a {"name":{"displayForm":["Claudio Piemonte, Alberto Gola, Alessandro Tarolli, Peter Fisher, Michael Ritzert, Volkmar Schulz, Torsten Solf"]},"note":["Available online 12 October 2012","Gesehen am 24.01.2022"],"id":{"eki":["1786966840"],"doi":["10.1016/j.nima.2012.10.012"]},"person":[{"given":"Claudio","roleDisplay":"VerfasserIn","role":"aut","display":"Piemonte, Claudio","family":"Piemonte"},{"given":"Alberto","display":"Gola, Alberto","roleDisplay":"VerfasserIn","role":"aut","family":"Gola"},{"family":"Tarolli","display":"Tarolli, Alessandro","roleDisplay":"VerfasserIn","role":"aut","given":"Alessandro"},{"family":"Fischer","display":"Fischer, Peter","roleDisplay":"VerfasserIn","role":"aut","given":"Peter"},{"display":"Ritzert, Michael","role":"aut","roleDisplay":"VerfasserIn","given":"Michael","family":"Ritzert"},{"family":"Schulz","display":"Schulz, Volkmar","role":"aut","roleDisplay":"VerfasserIn","given":"Volkmar"},{"given":"Torsten","role":"aut","roleDisplay":"VerfasserIn","display":"Solf, Torsten","family":"Solf"}],"title":[{"title_sort":"Performance of FBK SiPMs coupled to PETA3 read-out ASIC for PET application","title":"Performance of FBK SiPMs coupled to PETA3 read-out ASIC for PET application"}],"relHost":[{"part":{"pages":"345-346","text":"718(2013), Seite 345-346","year":"2013","extent":"2","volume":"718"},"id":{"zdb":["1466532-3"],"eki":["266014666"],"issn":["1872-9576"]},"note":["Gesehen am 24.05.23"],"titleAlt":[{"title":"Nuclear instruments & methods in physics research / A"}],"disp":"Performance of FBK SiPMs coupled to PETA3 read-out ASIC for PET applicationNuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment","origin":[{"publisher":"Elsevier ; North-Holland Publ. Co.","dateIssuedKey":"1994","publisherPlace":"[Amsterdam] ; Amsterdam","dateIssuedDisp":"1994-"}],"physDesc":[{"extent":"Online-Ressource"}],"pubHistory":["Nachgewiesen 226.1984 -"],"type":{"media":"Online-Ressource","bibl":"periodical"},"language":["eng"],"title":[{"title":"Nuclear instruments & methods in physics research","partname":"Accelerators, spectrometers, detectors and associated equipment","subtitle":"a journal on accelerators, instrumentation and techniques applied to research in nuclear and atomic physics, materials science and related fields in physics","title_sort":"Nuclear instruments & methods in physics research"}],"recId":"266014666"}],"recId":"1786966840","type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"origin":[{"dateIssuedKey":"2013","dateIssuedDisp":"2013"}],"physDesc":[{"extent":"2 S."}]} 
SRT |a PIEMONTECLPERFORMANC2013