The accuracy of helium ion CT based particle therapy range prediction: an experimental study comparing different particle and x-ray CT modalities
This work provides a quantitative assessment of helium ion CT (HeCT) for particle therapy treatment planning. For the first time, HeCT based range prediction accuracy in a heterogeneous tissue phantom is presented and compared to single-energy x-ray CT (SECT), dual-energy x-ray CT (DECT) and proton...
Saved in:
| Main Authors: | , , , , , , , , , |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
29 November 2021
|
| In: |
Physics in medicine and biology
Year: 2021, Volume: 66, Issue: 23, Pages: 1-17 |
| ISSN: | 1361-6560 |
| DOI: | 10.1088/1361-6560/ac33ec |
| Online Access: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1088/1361-6560/ac33ec |
| Author Notes: | L Volz, C-A Collins-Fekete, E Bär, S Brons, C Graeff, RP Johnson, A Runz, C Sarosiek, RW Schulte and J Seco |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1787330893 | ||
| 003 | DE-627 | ||
| 005 | 20230428005739.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 220127s2021 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1088/1361-6560/ac33ec |2 doi | |
| 035 | |a (DE-627)1787330893 | ||
| 035 | |a (DE-599)KXP1787330893 | ||
| 035 | |a (OCoLC)1341439399 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 29 |2 sdnb | ||
| 100 | 1 | |a Volz, Lennart |d 1992- |e VerfasserIn |0 (DE-588)1164508121 |0 (DE-627)1028942141 |0 (DE-576)510057004 |4 aut | |
| 245 | 1 | 4 | |a The accuracy of helium ion CT based particle therapy range prediction |b an experimental study comparing different particle and x-ray CT modalities |c L Volz, C-A Collins-Fekete, E Bär, S Brons, C Graeff, RP Johnson, A Runz, C Sarosiek, RW Schulte and J Seco |
| 264 | 1 | |c 29 November 2021 | |
| 300 | |a 17 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 27.01.2022 | ||
| 520 | |a This work provides a quantitative assessment of helium ion CT (HeCT) for particle therapy treatment planning. For the first time, HeCT based range prediction accuracy in a heterogeneous tissue phantom is presented and compared to single-energy x-ray CT (SECT), dual-energy x-ray CT (DECT) and proton CT (pCT). HeCT and pCT scans were acquired using the US pCT collaboration prototype particle CT scanner at the Heidelberg Ion-Beam Therapy Center. SECT and DECT scans were done with a Siemens Somatom Definition Flash and converted to RSP. A Catphan CTP404 module was used to study the RSP accuracy of HeCT. A custom phantom of 20 cm diameter containing several tissue equivalent plastic cubes was used to assess the spatial resolution of HeCT and compare it to DECT. A clinically realistic heterogeneous tissue phantom was constructed using cranial slices from a pig head placed inside a cylindrical phantom (ø150 mm). A proton beam (84.67 mm range) depth-dose measurement was acquired using a stack of GafchromicTM EBT-XD films in a central dosimetry insert in the phantom. CT scans of the phantom were acquired with each modality, and proton depth-dose estimates were simulated based on the reconstructions. The RSP accuracy of HeCT for the plastic phantom was found to be 0.3 ± 0.1%. The spatial resolution for HeCT of the cube phantom was 5.9 ± 0.4 lp cm−1 for central, and 7.6 ± 0.8 lp cm−1 for peripheral cubes, comparable to DECT spatial resolution (7.7 ± 0.3 lp cm−1 and 7.4 ± 0.2 lp cm−1, respectively). For the pig head, HeCT, SECT, DECT and pCT predicted range accuracy was 0.25%, −1.40%, −0.45% and 0.39%, respectively. In this study, HeCT acquired with a prototype system showed potential for particle therapy treatment planning, offering RSP accuracy, spatial resolution, and range prediction accuracy comparable to that achieved with a commercial DECT scanner. Still, technical improvements of HeCT are needed to enable clinical implementation. | ||
| 700 | 1 | |a Collins-Fekete, C.-A. |e VerfasserIn |4 aut | |
| 700 | 1 | |a Bär, E. |e VerfasserIn |4 aut | |
| 700 | 1 | |a Brons, Stephan |e VerfasserIn |0 (DE-588)1072782375 |0 (DE-627)828233594 |0 (DE-576)434240478 |4 aut | |
| 700 | 1 | |a Graeff, C. |e VerfasserIn |4 aut | |
| 700 | 1 | |a Johnson, R. P. |e VerfasserIn |4 aut | |
| 700 | 1 | |a Runz, Armin |e VerfasserIn |0 (DE-588)116699953X |0 (DE-627)1030846480 |0 (DE-576)510993516 |4 aut | |
| 700 | 1 | |a Sarosiek, C. |e VerfasserIn |4 aut | |
| 700 | 1 | |a Schulte, R. W. |e VerfasserIn |4 aut | |
| 700 | 1 | |a Seco, Joao |e VerfasserIn |0 (DE-588)1120955866 |0 (DE-627)874146615 |0 (DE-576)480627010 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Physics in medicine and biology |d Bristol : IOP Publ., 1956 |g 66(2021), 23, Artikel-ID 235010, Seite 1-17 |h Online-Ressource |w (DE-627)269016163 |w (DE-600)1473501-5 |w (DE-576)088704130 |x 1361-6560 |7 nnas |a The accuracy of helium ion CT based particle therapy range prediction an experimental study comparing different particle and x-ray CT modalities |
| 773 | 1 | 8 | |g volume:66 |g year:2021 |g number:23 |g elocationid:235010 |g pages:1-17 |g extent:17 |a The accuracy of helium ion CT based particle therapy range prediction an experimental study comparing different particle and x-ray CT modalities |
| 856 | 4 | 0 | |u https://doi.org/10.1088/1361-6560/ac33ec |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20220127 | ||
| 993 | |a Article | ||
| 994 | |a 2021 | ||
| 998 | |g 1120955866 |a Seco, Joao |m 1120955866:Seco, Joao |d 130000 |e 130000PS1120955866 |k 0/130000/ |p 10 |y j | ||
| 998 | |g 116699953X |a Runz, Armin |m 116699953X:Runz, Armin |p 7 | ||
| 998 | |g 1072782375 |a Brons, Stephan |m 1072782375:Brons, Stephan |p 2 | ||
| 998 | |g 1164508121 |a Volz, Lennart |m 1164508121:Volz, Lennart |p 1 |x j | ||
| 999 | |a KXP-PPN1787330893 |e 4045759190 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"person":[{"role":"aut","given":"Lennart","display":"Volz, Lennart","family":"Volz"},{"role":"aut","given":"C.-A.","family":"Collins-Fekete","display":"Collins-Fekete, C.-A."},{"role":"aut","given":"E.","display":"Bär, E.","family":"Bär"},{"given":"Stephan","role":"aut","display":"Brons, Stephan","family":"Brons"},{"family":"Graeff","display":"Graeff, C.","given":"C.","role":"aut"},{"family":"Johnson","display":"Johnson, R. P.","given":"R. P.","role":"aut"},{"role":"aut","given":"Armin","family":"Runz","display":"Runz, Armin"},{"display":"Sarosiek, C.","family":"Sarosiek","given":"C.","role":"aut"},{"given":"R. W.","role":"aut","display":"Schulte, R. W.","family":"Schulte"},{"display":"Seco, Joao","family":"Seco","role":"aut","given":"Joao"}],"language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Gesehen am 27.01.2022"],"origin":[{"dateIssuedDisp":"29 November 2021","dateIssuedKey":"2021"}],"title":[{"title":"The accuracy of helium ion CT based particle therapy range prediction","subtitle":"an experimental study comparing different particle and x-ray CT modalities","title_sort":"accuracy of helium ion CT based particle therapy range prediction"}],"recId":"1787330893","name":{"displayForm":["L Volz, C-A Collins-Fekete, E Bär, S Brons, C Graeff, RP Johnson, A Runz, C Sarosiek, RW Schulte and J Seco"]},"physDesc":[{"extent":"17 S."}],"relHost":[{"id":{"zdb":["1473501-5"],"issn":["1361-6560"],"eki":["269016163"]},"recId":"269016163","pubHistory":["1.1956 -"],"physDesc":[{"extent":"Online-Ressource"}],"language":["eng"],"part":{"issue":"23","year":"2021","text":"66(2021), 23, Artikel-ID 235010, Seite 1-17","pages":"1-17","extent":"17","volume":"66"},"origin":[{"publisher":"IOP Publ.","dateIssuedKey":"1956","dateIssuedDisp":"1956-","publisherPlace":"Bristol"}],"note":["Gesehen am 28.01.2019","Fortsetzung der Druck-Ausgabe"],"type":{"media":"Online-Ressource","bibl":"periodical"},"title":[{"title":"Physics in medicine and biology","subtitle":"an official journal of the Institute of Physics and Engineering in Medicine","title_sort":"Physics in medicine and biology"}],"disp":"The accuracy of helium ion CT based particle therapy range prediction an experimental study comparing different particle and x-ray CT modalitiesPhysics in medicine and biology"}],"id":{"doi":["10.1088/1361-6560/ac33ec"],"eki":["1787330893"]}} | ||
| SRT | |a VOLZLENNARACCURACYOF2920 | ||