Commissioning and performance of TITAN’s Multiple-Reflection Time-of-Flight Mass-Spectrometer and isobar separator

TRIUMF’s Ion Trap for Atomic and Nuclear science (TITAN) has specialized in fast Penning Trap mass spectrometry of very short-lived radioactive isotopes. The facility has been upgraded with a Multiple-Reflection Time-of-Flight Mass Spectrometer (MR-TOF-MS) to continue its quest towards more exotic n...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Reiter, Moritz Pascal (VerfasserIn) , Andrés, S. Ayet San (VerfasserIn) , Bergmann, J. (VerfasserIn) , Dickel, T. (VerfasserIn) , Dilling, J. (VerfasserIn) , Jacobs, A. (VerfasserIn) , Kwiatkowski, A. A. (VerfasserIn) , Plaß, W. R. (VerfasserIn) , Scheidenberger, C. (VerfasserIn) , Short, D. (VerfasserIn) , Will, C. (VerfasserIn) , Babcock, C. (VerfasserIn) , Dunling, E. (VerfasserIn) , Finlay, A. (VerfasserIn) , Hornung, C. (VerfasserIn) , Jesch, C. (VerfasserIn) , Klawitter, R. (VerfasserIn) , Kootte, B. (VerfasserIn) , Lascar, D. (VerfasserIn) , Leistenschneider, E. (VerfasserIn) , Murböck, T. (VerfasserIn) , Paul, Stefan Felix (VerfasserIn) , Yavor, M. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 22 September 2021
In: Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment
Year: 2021, Jahrgang: 1018, Pages: 1-14
ISSN:1872-9576
DOI:10.1016/j.nima.2021.165823
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.nima.2021.165823
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0168900221008081
Volltext
Verfasserangaben:M. P. Reiter, S. Ayet San Andrés, J. Bergmann, T. Dickel, J. Dilling, A. Jacobs, A. A. Kwiatkowski, W. R. Plaß, C. Scheidenberger, D. Short, C. Will, C. Babcock, E. Dunling, A. Finlay, C. Hornung, C. Jesch, R. Klawitter, B. Kootte, D. Lascar, E. Leistenschneider, T. Murböck, S. F. Paul, M. Yavor for the TITAN Collaboration

MARC

LEADER 00000caa a2200000 c 4500
001 1787346463
003 DE-627
005 20220820114905.0
007 cr uuu---uuuuu
008 220127s2021 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.nima.2021.165823  |2 doi 
035 |a (DE-627)1787346463 
035 |a (DE-599)KXP1787346463 
035 |a (OCoLC)1341439038 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 29  |2 sdnb 
100 1 |a Reiter, Moritz Pascal  |e VerfasserIn  |0 (DE-588)1080157735  |0 (DE-627)843885726  |0 (DE-576)453357628  |4 aut 
245 1 0 |a Commissioning and performance of TITAN’s Multiple-Reflection Time-of-Flight Mass-Spectrometer and isobar separator  |c M. P. Reiter, S. Ayet San Andrés, J. Bergmann, T. Dickel, J. Dilling, A. Jacobs, A. A. Kwiatkowski, W. R. Plaß, C. Scheidenberger, D. Short, C. Will, C. Babcock, E. Dunling, A. Finlay, C. Hornung, C. Jesch, R. Klawitter, B. Kootte, D. Lascar, E. Leistenschneider, T. Murböck, S. F. Paul, M. Yavor for the TITAN Collaboration 
264 1 |c 22 September 2021 
300 |a 14 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 27.01.2022 
520 |a TRIUMF’s Ion Trap for Atomic and Nuclear science (TITAN) has specialized in fast Penning Trap mass spectrometry of very short-lived radioactive isotopes. The facility has been upgraded with a Multiple-Reflection Time-of-Flight Mass Spectrometer (MR-TOF-MS) to continue its quest towards more exotic nuclides, which are critical for our understanding of nuclear structure effects far from the valley of beta stability and for the nucleosynthesis of heavy elements in explosive astrophysical environments. In this publication, we discuss the implementation, operation and performance of TITAN’s MR-TOF-MS as a stand-alone high-precision mass spectrometer and as an isobar separator. By using the novel mass-selective re-trapping technique for the isobar separation, the MR-TOF-MS can consecutively perform separation and mass measurement of the same ion population, acting as its own isobar separator. The device boosts the dynamic range and reach of the TITAN facility by several orders of magnitude. The MR-TOF-MS reaches a high mass resolving power (m/Δm∼400000), high precision and mass accuracy (δm/m<10−7), is fast (common cycle time 20ms), shows high sensitivity and very large dynamic range (ion of interest to contaminant ratios of up to 1 to 106). 
650 4 |a Exotic nuclei 
650 4 |a Isobar separator 
650 4 |a Mass spectrometry 
650 4 |a MR-TOF-MS 
650 4 |a Radioactive Ion Beams 
650 4 |a TITAN 
700 1 |a Andrés, S. Ayet San  |e VerfasserIn  |4 aut 
700 1 |a Bergmann, J.  |e VerfasserIn  |4 aut 
700 1 |a Dickel, T.  |e VerfasserIn  |4 aut 
700 1 |a Dilling, J.  |e VerfasserIn  |4 aut 
700 1 |a Jacobs, A.  |e VerfasserIn  |4 aut 
700 1 |a Kwiatkowski, A. A.  |e VerfasserIn  |4 aut 
700 1 |a Plaß, W. R.  |e VerfasserIn  |4 aut 
700 1 |a Scheidenberger, C.  |e VerfasserIn  |4 aut 
700 1 |a Short, D.  |e VerfasserIn  |4 aut 
700 1 |a Will, C.  |e VerfasserIn  |4 aut 
700 1 |a Babcock, C.  |e VerfasserIn  |4 aut 
700 1 |a Dunling, E.  |e VerfasserIn  |4 aut 
700 1 |a Finlay, A.  |e VerfasserIn  |4 aut 
700 1 |a Hornung, C.  |e VerfasserIn  |4 aut 
700 1 |a Jesch, C.  |e VerfasserIn  |4 aut 
700 1 |a Klawitter, R.  |e VerfasserIn  |4 aut 
700 1 |a Kootte, B.  |e VerfasserIn  |4 aut 
700 1 |a Lascar, D.  |e VerfasserIn  |4 aut 
700 1 |a Leistenschneider, E.  |e VerfasserIn  |4 aut 
700 1 |a Murböck, T.  |e VerfasserIn  |4 aut 
700 1 |a Paul, Stefan Felix  |d 1992-  |e VerfasserIn  |0 (DE-588)114497772X  |0 (DE-627)1005141428  |0 (DE-576)495553034  |4 aut 
700 1 |a Yavor, M.  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment  |d [Amsterdam] : Elsevier, 1984  |g 1018(2021), Artikel-ID 165823, Seite 1-14  |h Online-Ressource  |w (DE-627)266014666  |w (DE-600)1466532-3  |w (DE-576)074959743  |x 1872-9576  |7 nnas  |a Commissioning and performance of TITAN’s Multiple-Reflection Time-of-Flight Mass-Spectrometer and isobar separator 
773 1 8 |g volume:1018  |g year:2021  |g elocationid:165823  |g pages:1-14  |g extent:14  |a Commissioning and performance of TITAN’s Multiple-Reflection Time-of-Flight Mass-Spectrometer and isobar separator 
856 4 0 |u https://doi.org/10.1016/j.nima.2021.165823  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0168900221008081  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20220127 
993 |a Article 
994 |a 2021 
998 |g 114497772X  |a Paul, Stefan Felix  |m 114497772X:Paul, Stefan Felix  |d 130000  |e 130000PP114497772X  |k 0/130000/  |p 22 
999 |a KXP-PPN1787346463  |e 4045978445 
BIB |a Y 
SER |a journal 
JSO |a {"name":{"displayForm":["M. P. Reiter, S. Ayet San Andrés, J. Bergmann, T. Dickel, J. Dilling, A. Jacobs, A. A. Kwiatkowski, W. R. Plaß, C. Scheidenberger, D. Short, C. Will, C. Babcock, E. Dunling, A. Finlay, C. Hornung, C. Jesch, R. Klawitter, B. Kootte, D. Lascar, E. Leistenschneider, T. Murböck, S. F. Paul, M. Yavor for the TITAN Collaboration"]},"origin":[{"dateIssuedDisp":"22 September 2021","dateIssuedKey":"2021"}],"id":{"doi":["10.1016/j.nima.2021.165823"],"eki":["1787346463"]},"physDesc":[{"extent":"14 S."}],"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"origin":[{"publisherPlace":"[Amsterdam] ; Amsterdam","dateIssuedKey":"1994","publisher":"Elsevier ; North-Holland Publ. Co.","dateIssuedDisp":"1994-"}],"id":{"zdb":["1466532-3"],"eki":["266014666"],"issn":["1872-9576"]},"type":{"media":"Online-Ressource","bibl":"periodical"},"disp":"Commissioning and performance of TITAN’s Multiple-Reflection Time-of-Flight Mass-Spectrometer and isobar separatorNuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment","note":["Gesehen am 24.05.23"],"language":["eng"],"recId":"266014666","pubHistory":["Nachgewiesen 226.1984 -"],"titleAlt":[{"title":"Nuclear instruments & methods in physics research / A"}],"part":{"extent":"14","volume":"1018","text":"1018(2021), Artikel-ID 165823, Seite 1-14","pages":"1-14","year":"2021"},"title":[{"title_sort":"Nuclear instruments & methods in physics research","title":"Nuclear instruments & methods in physics research","subtitle":"a journal on accelerators, instrumentation and techniques applied to research in nuclear and atomic physics, materials science and related fields in physics","partname":"Accelerators, spectrometers, detectors and associated equipment"}]}],"person":[{"roleDisplay":"VerfasserIn","display":"Reiter, Moritz Pascal","role":"aut","family":"Reiter","given":"Moritz Pascal"},{"roleDisplay":"VerfasserIn","display":"Andrés, S. Ayet San","role":"aut","family":"Andrés","given":"S. Ayet San"},{"given":"J.","family":"Bergmann","role":"aut","roleDisplay":"VerfasserIn","display":"Bergmann, J."},{"role":"aut","roleDisplay":"VerfasserIn","display":"Dickel, T.","given":"T.","family":"Dickel"},{"roleDisplay":"VerfasserIn","display":"Dilling, J.","role":"aut","family":"Dilling","given":"J."},{"role":"aut","roleDisplay":"VerfasserIn","display":"Jacobs, A.","given":"A.","family":"Jacobs"},{"family":"Kwiatkowski","given":"A. A.","display":"Kwiatkowski, A. A.","roleDisplay":"VerfasserIn","role":"aut"},{"family":"Plaß","given":"W. R.","roleDisplay":"VerfasserIn","display":"Plaß, W. R.","role":"aut"},{"family":"Scheidenberger","given":"C.","display":"Scheidenberger, C.","roleDisplay":"VerfasserIn","role":"aut"},{"display":"Short, D.","roleDisplay":"VerfasserIn","role":"aut","family":"Short","given":"D."},{"family":"Will","given":"C.","display":"Will, C.","roleDisplay":"VerfasserIn","role":"aut"},{"role":"aut","display":"Babcock, C.","roleDisplay":"VerfasserIn","given":"C.","family":"Babcock"},{"family":"Dunling","given":"E.","roleDisplay":"VerfasserIn","display":"Dunling, E.","role":"aut"},{"roleDisplay":"VerfasserIn","display":"Finlay, A.","role":"aut","family":"Finlay","given":"A."},{"role":"aut","roleDisplay":"VerfasserIn","display":"Hornung, C.","given":"C.","family":"Hornung"},{"given":"C.","family":"Jesch","role":"aut","display":"Jesch, C.","roleDisplay":"VerfasserIn"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Klawitter, R.","given":"R.","family":"Klawitter"},{"display":"Kootte, B.","roleDisplay":"VerfasserIn","role":"aut","family":"Kootte","given":"B."},{"family":"Lascar","given":"D.","display":"Lascar, D.","roleDisplay":"VerfasserIn","role":"aut"},{"family":"Leistenschneider","given":"E.","display":"Leistenschneider, E.","roleDisplay":"VerfasserIn","role":"aut"},{"family":"Murböck","given":"T.","display":"Murböck, T.","roleDisplay":"VerfasserIn","role":"aut"},{"given":"Stefan Felix","family":"Paul","role":"aut","roleDisplay":"VerfasserIn","display":"Paul, Stefan Felix"},{"given":"M.","family":"Yavor","role":"aut","display":"Yavor, M.","roleDisplay":"VerfasserIn"}],"title":[{"title_sort":"Commissioning and performance of TITAN’s Multiple-Reflection Time-of-Flight Mass-Spectrometer and isobar separator","title":"Commissioning and performance of TITAN’s Multiple-Reflection Time-of-Flight Mass-Spectrometer and isobar separator"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Gesehen am 27.01.2022"],"language":["eng"],"recId":"1787346463"} 
SRT |a REITERMORICOMMISSION2220