Study design of the man and machine trial: a prospective international controlled noninferiority trial comparing manual with robotic catheter ablation for treatment of atrial fibrillation

Study Design of the Man and Machine Trial. Background: Pulmonary vein isolation (PVI) has become the cornerstone procedure for the treatment of symptomatic drug-resistant atrial fibrillation (AF). At the present time, circumferential PVI (CPVI) using irrigated radiofrequency (RF) is the mostly used...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Rillig, Andreas (VerfasserIn) , Schmidt, Boris (VerfasserIn) , Steven, Daniel (VerfasserIn) , Meyerfeldt, Udo (VerfasserIn) , Di Biase, Luigi (VerfasserIn) , Wissner, Erik (VerfasserIn) , Becker, Rüdiger (VerfasserIn) , Thomas, Dierk (VerfasserIn) , Wohlmuth, Peter (VerfasserIn) , Gallinghouse, G. Joseph (VerfasserIn) , Scholz, Eberhard P. (VerfasserIn) , Jung, Werner (VerfasserIn) , Willems, Stefan (VerfasserIn) , Natale, Andrea (VerfasserIn) , Ouyang, Feifan (VerfasserIn) , Kuck, Karl Heinz (VerfasserIn) , Tilz, Roland (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2013
In: Journal of cardiovascular electrophysiology
Year: 2013, Jahrgang: 24, Heft: 1, Pages: 40-46
ISSN:1540-8167
DOI:10.1111/j.1540-8167.2012.02418.x
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1111/j.1540-8167.2012.02418.x
Verlag, lizenzpflichtig, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1111/j.1540-8167.2012.02418.x
Volltext
Verfasserangaben:Andreas Rillig, Boris Schmidt, Daniel Steven, Udo Meyerfeldt, Luigi Di Biase, Erik Wissner, Rüdiger Becker, Dierk Thomas, Peter Wohlmuth, G. Joseph Gallinghouse, Eberhardt Scholz, Werner Jung, Stefan Willems, Andrea Natale, Feifan Ouyang, Karl Heinz Kuck, and Roland Tilz

MARC

LEADER 00000caa a2200000 c 4500
001 1787967735
003 DE-627
005 20220820120647.0
007 cr uuu---uuuuu
008 220201s2013 xx |||||o 00| ||eng c
024 7 |a 10.1111/j.1540-8167.2012.02418.x  |2 doi 
035 |a (DE-627)1787967735 
035 |a (DE-599)KXP1787967735 
035 |a (OCoLC)1341440267 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Rillig, Andreas  |d 1976-  |e VerfasserIn  |0 (DE-588)132959054  |0 (DE-627)691033765  |0 (DE-576)299528634  |4 aut 
245 1 0 |a Study design of the man and machine trial  |b a prospective international controlled noninferiority trial comparing manual with robotic catheter ablation for treatment of atrial fibrillation  |c Andreas Rillig, Boris Schmidt, Daniel Steven, Udo Meyerfeldt, Luigi Di Biase, Erik Wissner, Rüdiger Becker, Dierk Thomas, Peter Wohlmuth, G. Joseph Gallinghouse, Eberhardt Scholz, Werner Jung, Stefan Willems, Andrea Natale, Feifan Ouyang, Karl Heinz Kuck, and Roland Tilz 
264 1 |c 2013 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a First published: 25 July 2012 
500 |a Gesehen am 01.02.2022 
520 |a Study Design of the Man and Machine Trial. Background: Pulmonary vein isolation (PVI) has become the cornerstone procedure for the treatment of symptomatic drug-resistant atrial fibrillation (AF). At the present time, circumferential PVI (CPVI) using irrigated radiofrequency (RF) is the mostly used ablation technique. However, for CPVI, precise catheter navigation and excellent catheter stability is crucial thereby requiring experienced operators. Robotic navigation systems have been introduced to facilitate catheter navigation and to improve catheter stability, therefore potentially increasing procedural success and making CPVI accessible to less experienced operators. To date, no prospective randomized trial has evaluated the efficacy and safety of CPVI using RNS compared to manually performed ablation. Methods: In this prospective international multicenter noninferiority trial, 258 patients with either paroxysmal or short-standing persistent AF will be randomized for comparison of PVI using either manual or robotic ablation. In all patients, CPVI will be performed using irrigated RF ablation in combination with a 3D mapping system. The primary endpoint of the trial is the absence of AF or atrial tachycardia without antiarrhythmic drug therapy during 12-month follow-up. Secondary endpoints will be evaluation of periprocedural complications and procedural data such as procedure time, fluoroscopy time, as well as the incidence of esophageal injury assessed by endoscopy within 48 hours after the procedure. Conclusion: The “Man and Machine Trial” is the first prospective international randomized controlled multicenter noninferiority trial to compare manually performed CPVI with robotically navigated CPVI, evaluating both the safety and efficacy of the 2 techniques during a 12-month follow-up period. (J Cardiovasc Electrophysiol, Vol. 24, pp. 40-46, January 2013) 
650 4 |a atrial fibrillation 
650 4 |a catheter ablation 
650 4 |a pulmonary vein isolation 
650 4 |a randomized clinical trial 
650 4 |a robotics 
700 1 |a Schmidt, Boris  |e VerfasserIn  |4 aut 
700 1 |a Steven, Daniel  |e VerfasserIn  |4 aut 
700 1 |a Meyerfeldt, Udo  |e VerfasserIn  |4 aut 
700 1 |a Di Biase, Luigi  |e VerfasserIn  |4 aut 
700 1 |a Wissner, Erik  |e VerfasserIn  |4 aut 
700 1 |a Becker, Rüdiger  |e VerfasserIn  |0 (DE-588)1032502541  |0 (DE-627)738501409  |0 (DE-576)380071061  |4 aut 
700 1 |a Thomas, Dierk  |d 1974-  |e VerfasserIn  |0 (DE-588)123896258  |0 (DE-627)706465601  |0 (DE-576)29393164X  |4 aut 
700 1 |a Wohlmuth, Peter  |e VerfasserIn  |4 aut 
700 1 |a Gallinghouse, G. Joseph  |e VerfasserIn  |4 aut 
700 1 |a Scholz, Eberhard P.  |d 1978-  |e VerfasserIn  |0 (DE-588)13163660X  |0 (DE-627)512033994  |0 (DE-576)298640589  |4 aut 
700 1 |a Jung, Werner  |e VerfasserIn  |4 aut 
700 1 |a Willems, Stefan  |e VerfasserIn  |4 aut 
700 1 |a Natale, Andrea  |e VerfasserIn  |4 aut 
700 1 |a Ouyang, Feifan  |e VerfasserIn  |4 aut 
700 1 |a Kuck, Karl Heinz  |e VerfasserIn  |4 aut 
700 1 |a Tilz, Roland  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Journal of cardiovascular electrophysiology  |d Oxford : Wiley-Blackwell, 1990  |g 24(2013), 1 vom: Jan., Seite 40-46  |h Online-Ressource  |w (DE-627)325572011  |w (DE-600)2037519-0  |w (DE-576)094114013  |x 1540-8167  |7 nnas  |a Study design of the man and machine trial a prospective international controlled noninferiority trial comparing manual with robotic catheter ablation for treatment of atrial fibrillation 
773 1 8 |g volume:24  |g year:2013  |g number:1  |g month:01  |g pages:40-46  |g extent:7  |a Study design of the man and machine trial a prospective international controlled noninferiority trial comparing manual with robotic catheter ablation for treatment of atrial fibrillation 
856 4 0 |u https://doi.org/10.1111/j.1540-8167.2012.02418.x  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://onlinelibrary.wiley.com/doi/abs/10.1111/j.1540-8167.2012.02418.x  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20220201 
993 |a Article 
994 |a 2013 
998 |g 13163660X  |a Scholz, Eberhard P.  |m 13163660X:Scholz, Eberhard P.  |d 910000  |d 910100  |e 910000PS13163660X  |e 910100PS13163660X  |k 0/910000/  |k 1/910000/910100/  |p 11 
998 |g 123896258  |a Thomas, Dierk  |m 123896258:Thomas, Dierk  |d 910000  |d 910100  |e 910000PT123896258  |e 910100PT123896258  |k 0/910000/  |k 1/910000/910100/  |p 8 
998 |g 1032502541  |a Becker, Rüdiger  |m 1032502541:Becker, Rüdiger  |d 50000  |e 50000PB1032502541  |k 0/50000/  |p 7 
999 |a KXP-PPN1787967735  |e 4048873636 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"origin":[{"publisher":"Wiley-Blackwell ; Futura Publ. Co. ; Blackwell Publishing","dateIssuedDisp":"1990-","publisherPlace":"Oxford ; Armonk, NY ; Oxford [u.a.]","dateIssuedKey":"1990"}],"pubHistory":["1.1990 -"],"disp":"Study design of the man and machine trial a prospective international controlled noninferiority trial comparing manual with robotic catheter ablation for treatment of atrial fibrillationJournal of cardiovascular electrophysiology","part":{"volume":"24","pages":"40-46","year":"2013","text":"24(2013), 1 vom: Jan., Seite 40-46","extent":"7","issue":"1"},"id":{"doi":["10.1111/(ISSN)1540-8167"],"eki":["325572011"],"issn":["1540-8167"],"zdb":["2037519-0"]},"language":["eng"],"physDesc":[{"extent":"Online-Ressource"}],"recId":"325572011","titleAlt":[{"title":"JCE"}],"note":["Gesehen am 24.03.11"],"title":[{"title":"Journal of cardiovascular electrophysiology","subtitle":"JCE ; an official journal of the North American Society of Pacing and Electrophysiology ; the official journal of the Cardiac Electrophysiology Society","title_sort":"Journal of cardiovascular electrophysiology"}],"type":{"media":"Online-Ressource","bibl":"periodical"}}],"name":{"displayForm":["Andreas Rillig, Boris Schmidt, Daniel Steven, Udo Meyerfeldt, Luigi Di Biase, Erik Wissner, Rüdiger Becker, Dierk Thomas, Peter Wohlmuth, G. Joseph Gallinghouse, Eberhardt Scholz, Werner Jung, Stefan Willems, Andrea Natale, Feifan Ouyang, Karl Heinz Kuck, and Roland Tilz"]},"origin":[{"dateIssuedKey":"2013","dateIssuedDisp":"2013"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"person":[{"roleDisplay":"VerfasserIn","family":"Rillig","display":"Rillig, Andreas","given":"Andreas","role":"aut"},{"family":"Schmidt","display":"Schmidt, Boris","roleDisplay":"VerfasserIn","given":"Boris","role":"aut"},{"given":"Daniel","role":"aut","family":"Steven","display":"Steven, Daniel","roleDisplay":"VerfasserIn"},{"display":"Meyerfeldt, Udo","family":"Meyerfeldt","roleDisplay":"VerfasserIn","given":"Udo","role":"aut"},{"given":"Luigi","role":"aut","roleDisplay":"VerfasserIn","family":"Di Biase","display":"Di Biase, Luigi"},{"given":"Erik","role":"aut","display":"Wissner, Erik","family":"Wissner","roleDisplay":"VerfasserIn"},{"given":"Rüdiger","role":"aut","roleDisplay":"VerfasserIn","family":"Becker","display":"Becker, Rüdiger"},{"role":"aut","given":"Dierk","display":"Thomas, Dierk","family":"Thomas","roleDisplay":"VerfasserIn"},{"given":"Peter","role":"aut","family":"Wohlmuth","display":"Wohlmuth, Peter","roleDisplay":"VerfasserIn"},{"roleDisplay":"VerfasserIn","family":"Gallinghouse","display":"Gallinghouse, G. Joseph","given":"G. Joseph","role":"aut"},{"display":"Scholz, Eberhard P.","family":"Scholz","roleDisplay":"VerfasserIn","given":"Eberhard P.","role":"aut"},{"roleDisplay":"VerfasserIn","family":"Jung","display":"Jung, Werner","given":"Werner","role":"aut"},{"given":"Stefan","role":"aut","family":"Willems","display":"Willems, Stefan","roleDisplay":"VerfasserIn"},{"role":"aut","given":"Andrea","family":"Natale","display":"Natale, Andrea","roleDisplay":"VerfasserIn"},{"roleDisplay":"VerfasserIn","display":"Ouyang, Feifan","family":"Ouyang","role":"aut","given":"Feifan"},{"display":"Kuck, Karl Heinz","family":"Kuck","roleDisplay":"VerfasserIn","role":"aut","given":"Karl Heinz"},{"role":"aut","given":"Roland","display":"Tilz, Roland","family":"Tilz","roleDisplay":"VerfasserIn"}],"title":[{"subtitle":"a prospective international controlled noninferiority trial comparing manual with robotic catheter ablation for treatment of atrial fibrillation","title":"Study design of the man and machine trial","title_sort":"Study design of the man and machine trial"}],"note":["First published: 25 July 2012","Gesehen am 01.02.2022"],"recId":"1787967735","physDesc":[{"extent":"7 S."}],"id":{"doi":["10.1111/j.1540-8167.2012.02418.x"],"eki":["1787967735"]},"language":["eng"]} 
SRT |a RILLIGANDRSTUDYDESIG2013