Implantation of three-piece silicone toric additive IOLs in challenging clinical cases with high astigmatism
Purpose: To analyze the refractive outcomes and safety of three-piece silicone toric sulcus-fixated add-on intraocular lenses (IOLs) (HumanOptics/Dr.Schmidt Intraocularlinsen, Erlangen, Germany) in complex clinical cases with high astigmatism such as in cases with previous penetrating keratoplasty....
Gespeichert in:
| Hauptverfasser: | , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
February 12, 2013
|
| In: |
Journal of refractive surgery
Year: 2013, Jahrgang: 29, Heft: 3, Pages: 187-193 |
| ISSN: | 1938-2391 |
| DOI: | 10.3928/1081597X-20130212-01 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.3928/1081597X-20130212-01 Verlag, lizenzpflichtig, Volltext: https://journals.healio.com/doi/10.3928/1081597X-20130212-01 |
| Verfasserangaben: | Bettina C. Thomas, Gerd U. Auffarth, Josef Reiter, Mike P. Holzer, and Tanja M. Rabsilber |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1788472993 | ||
| 003 | DE-627 | ||
| 005 | 20220820122111.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 220203s2013 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.3928/1081597X-20130212-01 |2 doi | |
| 035 | |a (DE-627)1788472993 | ||
| 035 | |a (DE-599)KXP1788472993 | ||
| 035 | |a (OCoLC)1341439528 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Thomas, Bettina C. |e VerfasserIn |0 (DE-588)1118879422 |0 (DE-627)872356655 |0 (DE-576)479680574 |4 aut | |
| 245 | 1 | 0 | |a Implantation of three-piece silicone toric additive IOLs in challenging clinical cases with high astigmatism |c Bettina C. Thomas, Gerd U. Auffarth, Josef Reiter, Mike P. Holzer, and Tanja M. Rabsilber |
| 264 | 1 | |c February 12, 2013 | |
| 300 | |a 7 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 03.02.2022 | ||
| 520 | |a Purpose: To analyze the refractive outcomes and safety of three-piece silicone toric sulcus-fixated add-on intraocular lenses (IOLs) (HumanOptics/Dr.Schmidt Intraocularlinsen, Erlangen, Germany) in complex clinical cases with high astigmatism such as in cases with previous penetrating keratoplasty. - Methods: Interventional case series of 21 eyes of 20 patients enrolled at two German centers. Functional results including power vector analysis, accuracy of IOL power calculation, rotational stability, and postoperative complications were evaluated from 2 months to 6 years postoperatively. - Results: The preoperative subjective cylinder exceeded or was equal to −6.00 diopters (D) in 81% of eyes (range: −2.00 to −17.00 D). The median follow-up period was 7.6 months (range: 57 days to 6 years). The efficacy analysis focused on the 2 to 6 months follow-up visit. Postoperatively, there was a median reduction of astigmatism by 70.59% (subjective cylinder range: 0.00 to −5.00 D), improvement of uncorrected distance visual acuity, and unchanged median corrected distance visual acuity. The attempted spherical equivalent was achieved within ± 0.50 D in 45% and within ± 1.00 D in 65% of cases. Five eyes received secondary surgical alignment of axis. Other complications related to the surgical procedure were mainly transient shortly after implantation, such as intraocular pressure elevation (2 of 21 eyes) or corneal edema (2 of 21 eyes). Persisting changes were seen only in rare cases and included pigment dispersion (1 of 21 eyes) or corneal edema requiring a second keratoplasty within 9 months after surgery (2 of 21 eyes). - Conclusions: Toric add-on IOLs may be useful in reducing high astigmatism and anisometropia and increasing spectacle independence even in complex clinical conditions with high refractive errors. | ||
| 700 | 1 | |a Auffarth, Gerd U. |d 1964- |e VerfasserIn |0 (DE-588)123385261 |0 (DE-627)577130420 |0 (DE-576)293687277 |4 aut | |
| 700 | 1 | |a Reiter, Josef |e VerfasserIn |4 aut | |
| 700 | 1 | |a Holzer, Mike P. |d 1973- |e VerfasserIn |0 (DE-588)122217527 |0 (DE-627)705818640 |0 (DE-576)293157812 |4 aut | |
| 700 | 1 | |a Rabsilber, Tanja Marina |d 1977- |e VerfasserIn |0 (DE-588)128743271 |0 (DE-627)378689541 |0 (DE-576)297309609 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Journal of refractive surgery |d Thorofare, NJ : SLACK Inc., 1996 |g 29(2013), 3, Seite 187-193 |h Online-Ressource |w (DE-627)333811267 |w (DE-600)2056758-3 |w (DE-576)433787627 |x 1938-2391 |7 nnas |a Implantation of three-piece silicone toric additive IOLs in challenging clinical cases with high astigmatism |
| 773 | 1 | 8 | |g volume:29 |g year:2013 |g number:3 |g pages:187-193 |g extent:7 |a Implantation of three-piece silicone toric additive IOLs in challenging clinical cases with high astigmatism |
| 856 | 4 | 0 | |u https://doi.org/10.3928/1081597X-20130212-01 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://journals.healio.com/doi/10.3928/1081597X-20130212-01 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20220203 | ||
| 993 | |a Article | ||
| 994 | |a 2013 | ||
| 998 | |g 128743271 |a Rabsilber, Tanja Marina |m 128743271:Rabsilber, Tanja Marina |d 910000 |d 910900 |e 910000PR128743271 |e 910900PR128743271 |k 0/910000/ |k 1/910000/910900/ |p 5 |y j | ||
| 998 | |g 122217527 |a Holzer, Mike P. |m 122217527:Holzer, Mike P. |d 910000 |d 910900 |d 50000 |e 910000PH122217527 |e 910900PH122217527 |e 50000PH122217527 |k 0/910000/ |k 1/910000/910900/ |k 0/50000/ |p 4 | ||
| 998 | |g 123385261 |a Auffarth, Gerd U. |m 123385261:Auffarth, Gerd U. |d 910000 |d 910900 |e 910000PA123385261 |e 910900PA123385261 |k 0/910000/ |k 1/910000/910900/ |p 2 | ||
| 998 | |g 1118879422 |a Thomas, Bettina C. |m 1118879422:Thomas, Bettina C. |d 910000 |d 913000 |e 910000PT1118879422 |e 913000PT1118879422 |k 0/910000/ |k 1/910000/913000/ |p 1 |x j | ||
| 999 | |a KXP-PPN1788472993 |e 4050836688 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"id":{"eki":["1788472993"],"doi":["10.3928/1081597X-20130212-01"]},"person":[{"given":"Bettina C.","family":"Thomas","display":"Thomas, Bettina C.","role":"aut"},{"role":"aut","display":"Auffarth, Gerd U.","family":"Auffarth","given":"Gerd U."},{"given":"Josef","role":"aut","display":"Reiter, Josef","family":"Reiter"},{"given":"Mike P.","display":"Holzer, Mike P.","role":"aut","family":"Holzer"},{"family":"Rabsilber","role":"aut","display":"Rabsilber, Tanja Marina","given":"Tanja Marina"}],"origin":[{"dateIssuedDisp":"February 12, 2013","dateIssuedKey":"2013"}],"name":{"displayForm":["Bettina C. Thomas, Gerd U. Auffarth, Josef Reiter, Mike P. Holzer, and Tanja M. Rabsilber"]},"title":[{"title":"Implantation of three-piece silicone toric additive IOLs in challenging clinical cases with high astigmatism","title_sort":"Implantation of three-piece silicone toric additive IOLs in challenging clinical cases with high astigmatism"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"relHost":[{"note":["Gesehen am 26.09.24"],"recId":"333811267","physDesc":[{"extent":"Online-Ressource"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"language":["eng"],"pubHistory":["Nachgewiesen 12.1996 -"],"disp":"Implantation of three-piece silicone toric additive IOLs in challenging clinical cases with high astigmatismJournal of refractive surgery","title":[{"subtitle":"the official publication of the International Society of Refractive Surgery","title":"Journal of refractive surgery","title_sort":"Journal of refractive surgery"}],"origin":[{"dateIssuedDisp":"1996-","publisherPlace":"Thorofare, NJ","dateIssuedKey":"1996","publisher":"SLACK Inc."}],"part":{"pages":"187-193","text":"29(2013), 3, Seite 187-193","year":"2013","volume":"29","extent":"7","issue":"3"},"id":{"zdb":["2056758-3"],"eki":["333811267"],"issn":["1938-2391"]}}],"physDesc":[{"extent":"7 S."}],"recId":"1788472993","language":["eng"],"note":["Gesehen am 03.02.2022"]} | ||
| SRT | |a THOMASBETTIMPLANTATI1220 | ||