Design of a high-performance non-linear gradient coil for diffusion weighted MRI of the breast

Diffusion-weighted imaging (DWI) in the female breast is a magnetic resonance imaging (MRI) technique that complements clinical routine protocols, and that might provide an independent diagnostic value for specific clinical tasks in breast imaging. To further improve specificity of DWI in the breast...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Jia, Feng (VerfasserIn) , Littin, Sebastian (VerfasserIn) , Amrein, Philipp (VerfasserIn) , Yu, Huijun (VerfasserIn) , Magill, Arthur W. (VerfasserIn) , Kuder, Tristan Anselm (VerfasserIn) , Bickelhaupt, Sebastian (VerfasserIn) , Laun, Frederik (VerfasserIn) , Ladd, Mark E. (VerfasserIn) , Zaitsev, Maxim (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 14 August 2021
In: Journal of magnetic resonance
Year: 2021, Jahrgang: 331, Heft: 107052, Pages: 1-13
ISSN:1096-0856
DOI:10.1016/j.jmr.2021.107052
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.jmr.2021.107052
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S1090780721001415
Volltext
Verfasserangaben:Feng Jia, Sebastian Littin, Philipp Amrein, Huijun Yu, Arthur W. Magill, Tristan A. Kuder, Sebastian Bickelhaupt, Frederik Laun, Mark E. Ladd, Maxim Zaitsev

MARC

LEADER 00000caa a2200000 c 4500
001 1788707419
003 DE-627
005 20220820123701.0
007 cr uuu---uuuuu
008 220207s2021 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.jmr.2021.107052  |2 doi 
035 |a (DE-627)1788707419 
035 |a (DE-599)KXP1788707419 
035 |a (OCoLC)1341441489 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Jia, Feng  |e VerfasserIn  |0 (DE-588)14256284X  |0 (DE-627)704258676  |0 (DE-576)331814455  |4 aut 
245 1 0 |a Design of a high-performance non-linear gradient coil for diffusion weighted MRI of the breast  |c Feng Jia, Sebastian Littin, Philipp Amrein, Huijun Yu, Arthur W. Magill, Tristan A. Kuder, Sebastian Bickelhaupt, Frederik Laun, Mark E. Ladd, Maxim Zaitsev 
264 1 |c 14 August 2021 
300 |a 13 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 07.02.2022 
520 |a Diffusion-weighted imaging (DWI) in the female breast is a magnetic resonance imaging (MRI) technique that complements clinical routine protocols, and that might provide an independent diagnostic value for specific clinical tasks in breast imaging. To further improve specificity of DWI in the breast, stronger and faster diffusion weighting is advantageous. Here, a dedicated gradient coil is designed, targeted at diffusion weighting in the female breast, with the peak gradient magnitude exceeding that of the current clinical MR scanners by an order of a magnitude. Design of application-tailored gradient coils in MRI has recently attracted increased attention. With the target application in mind, the gradient coil is designed on an irregularly shaped semi-open current-carrying surface. Due to the coil former closely fitting the non-spherical target region, non-linear encoding fields become particularly advantageous for achieving locally exceptionally high gradient strengths. As breast tissue has a predominantly isotropic cellular microstructure, the direction of the diffusion-weighting gradient may be allowed to vary within the target volume. However, due to the quadratic dependency of the b-factor on the gradient strength, variation of the gradient magnitude should be carefully controlled. To achieve the above design goals the corresponding multi-objective optimization problem is reformulated as a constrained optimization, allowing for flexible and precise control of the coil properties. A novel constraint is proposed, limiting gradient magnitude variation within every slice while allowing for variations in both the direction of the gradient within the slice and the magnitude across the slices. These innovations enable the design of a unilateral coil for diffusion weighting in the female breast with local gradient strengths exceeding 1 T/m with highly homogeneous diffusion weighting for imaging in the coronal slice orientation. 
650 4 |a Diffusion weighted imaging 
650 4 |a Gradient coil design 
650 4 |a Magnetic resonance imaging 
650 4 |a Non-linear spatial encoding magnetic fields 
700 1 |a Littin, Sebastian  |e VerfasserIn  |4 aut 
700 1 |a Amrein, Philipp  |e VerfasserIn  |4 aut 
700 1 |a Yu, Huijun  |e VerfasserIn  |4 aut 
700 1 |a Magill, Arthur W.  |e VerfasserIn  |0 (DE-588)1251280609  |0 (DE-627)1788707389  |4 aut 
700 1 |a Kuder, Tristan Anselm  |e VerfasserIn  |0 (DE-588)14203911X  |0 (DE-627)704126338  |0 (DE-576)326749675  |4 aut 
700 1 |a Bickelhaupt, Sebastian  |d 1984-  |e VerfasserIn  |0 (DE-588)1074040759  |0 (DE-627)83020668X  |0 (DE-576)435548131  |4 aut 
700 1 |a Laun, Frederik  |e VerfasserIn  |4 aut 
700 1 |a Ladd, Mark E.  |e VerfasserIn  |0 (DE-588)108120964X  |0 (DE-627)845690507  |0 (DE-576)454039999  |4 aut 
700 1 |a Zaitsev, Maxim  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Journal of magnetic resonance  |d Amsterdam [u.a.] : Elsevier, 1997  |g 331(2021), 107052, Seite 1-13  |h Online-Ressource  |w (DE-627)267327137  |w (DE-600)1469665-4  |w (DE-576)103373225  |x 1096-0856  |7 nnas  |a Design of a high-performance non-linear gradient coil for diffusion weighted MRI of the breast 
773 1 8 |g volume:331  |g year:2021  |g number:107052  |g pages:1-13  |g extent:13  |a Design of a high-performance non-linear gradient coil for diffusion weighted MRI of the breast 
856 4 0 |u https://doi.org/10.1016/j.jmr.2021.107052  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S1090780721001415  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20220207 
993 |a Article 
994 |a 2021 
998 |g 108120964X  |a Ladd, Mark E.  |m 108120964X:Ladd, Mark E.  |d 130000  |d 50000  |e 130000PL108120964X  |e 50000PL108120964X  |k 0/130000/  |k 0/50000/  |p 9 
998 |g 1074040759  |a Bickelhaupt, Sebastian  |m 1074040759:Bickelhaupt, Sebastian  |d 50000  |e 50000PB1074040759  |k 0/50000/  |p 7 
998 |g 14203911X  |a Kuder, Tristan Anselm  |m 14203911X:Kuder, Tristan Anselm  |d 50000  |d 130000  |e 50000PK14203911X  |e 130000PK14203911X  |k 0/50000/  |k 0/130000/  |p 6 
998 |g 1251280609  |a Magill, Arthur W.  |m 1251280609:Magill, Arthur W.  |d 50000  |e 50000PM1251280609  |k 0/50000/  |p 5 
999 |a KXP-PPN1788707419  |e 4052228200 
BIB |a Y 
SER |a journal 
JSO |a {"recId":"1788707419","relHost":[{"recId":"267327137","physDesc":[{"extent":"Online-Ressource"}],"id":{"issn":["1096-0856"],"zdb":["1469665-4"],"eki":["267327137"]},"title":[{"subtitle":"JMR","title_sort":"Journal of magnetic resonance","title":"Journal of magnetic resonance"}],"note":["Gesehen am 09.08.24"],"pubHistory":["Volume 124, issue 1 (January 1997)-volume 213, issue 2 (December 2011) ; Volume 214 (January 2012)-"],"origin":[{"publisherPlace":"Amsterdam [u.a.] ; [Erscheinungsort nicht ermittelbar]","publisher":"Elsevier ; Academic Press","dateIssuedKey":"2002","dateIssuedDisp":"2002-"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"disp":"Design of a high-performance non-linear gradient coil for diffusion weighted MRI of the breastJournal of magnetic resonance","language":["eng"],"part":{"extent":"13","volume":"331","text":"331(2021), 107052, Seite 1-13","issue":"107052","year":"2021","pages":"1-13"},"titleAlt":[{"title":"JMR"}]}],"physDesc":[{"extent":"13 S."}],"name":{"displayForm":["Feng Jia, Sebastian Littin, Philipp Amrein, Huijun Yu, Arthur W. Magill, Tristan A. Kuder, Sebastian Bickelhaupt, Frederik Laun, Mark E. Ladd, Maxim Zaitsev"]},"id":{"doi":["10.1016/j.jmr.2021.107052"],"eki":["1788707419"]},"title":[{"title_sort":"Design of a high-performance non-linear gradient coil for diffusion weighted MRI of the breast","title":"Design of a high-performance non-linear gradient coil for diffusion weighted MRI of the breast"}],"origin":[{"dateIssuedKey":"2021","dateIssuedDisp":"14 August 2021"}],"note":["Gesehen am 07.02.2022"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"person":[{"role":"aut","given":"Feng","display":"Jia, Feng","family":"Jia"},{"given":"Sebastian","role":"aut","display":"Littin, Sebastian","family":"Littin"},{"given":"Philipp","role":"aut","family":"Amrein","display":"Amrein, Philipp"},{"given":"Huijun","role":"aut","family":"Yu","display":"Yu, Huijun"},{"role":"aut","given":"Arthur W.","display":"Magill, Arthur W.","family":"Magill"},{"given":"Tristan Anselm","role":"aut","family":"Kuder","display":"Kuder, Tristan Anselm"},{"given":"Sebastian","role":"aut","family":"Bickelhaupt","display":"Bickelhaupt, Sebastian"},{"display":"Laun, Frederik","family":"Laun","given":"Frederik","role":"aut"},{"given":"Mark E.","role":"aut","family":"Ladd","display":"Ladd, Mark E."},{"role":"aut","given":"Maxim","display":"Zaitsev, Maxim","family":"Zaitsev"}]} 
SRT |a JIAFENGLITDESIGNOFAH1420