Intensity-modulated radiation therapy (IMRT) with different combinations of treatment-planning systems and linacs: issues and how to detect them

Purpose: To compare different combinations of intensity-modulated radiation therapy (IMRT) system components with regard to quality assurance (QA), especially robustness against malfunctions and dosimetry. Material and Methods: Three different treatment-planning systems (TPS), two types of linacs an...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Dobler, Barbara (VerfasserIn) , Lorenz, Friedlieb (VerfasserIn) , Wertz, Hansjörg (VerfasserIn) , Polednik, Martin (VerfasserIn) , Wolff, Dirk (VerfasserIn) , Steil, Volker (VerfasserIn) , Lohr, Frank (VerfasserIn) , Wenz, Frederik (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 1 August 2006
In: Strahlentherapie und Onkologie
Year: 2006, Jahrgang: 182, Heft: 8, Pages: 481-488
ISSN:1439-099X
DOI:10.1007/s00066-006-1544-6
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1007/s00066-006-1544-6
Volltext
Verfasserangaben:Barbara Dobler, Friedlieb Lorenz, Hansjörg Wertz, Martin Polednik, Dirk Wolff, Volker Steil, Frank Lohr, Frederik Wenz

MARC

LEADER 00000caa a2200000 c 4500
001 1794160272
003 DE-627
005 20240424075647.0
007 cr uuu---uuuuu
008 220301s2006 xx |||||o 00| ||eng c
024 7 |a 10.1007/s00066-006-1544-6  |2 doi 
035 |a (DE-627)1794160272 
035 |a (DE-599)KXP1794160272 
035 |a (OCoLC)1341445587 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Dobler, Barbara  |e VerfasserIn  |0 (DE-588)1253242364  |0 (DE-627)1795266384  |4 aut 
245 1 0 |a Intensity-modulated radiation therapy (IMRT) with different combinations of treatment-planning systems and linacs  |b issues and how to detect them  |c Barbara Dobler, Friedlieb Lorenz, Hansjörg Wertz, Martin Polednik, Dirk Wolff, Volker Steil, Frank Lohr, Frederik Wenz 
264 1 |c 1 August 2006 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 01.03.2022 
520 |a Purpose: To compare different combinations of intensity-modulated radiation therapy (IMRT) system components with regard to quality assurance (QA), especially robustness against malfunctions and dosimetry. Material and Methods: Three different treatment-planning systems (TPS), two types of linacs and three multileaf collimator (MLC) types were compared: commissioning procedures were performed for the combination of the TPS Corvus (R) 5.0 (Nomos) and KonRad (R) v2.1.3 (Siemens OCS) with the Linacs KD2 (R) (Siemens) and Synergy (R) (Elekta). For PrecisePLAN (R) 2.03 (Elekta) measurements were performed for Elekta Synergy only. As record and verify (R&V) system Multi-Access v7 (R) (IMPAC) was used. The use of the serial tomotherapy system Peacock (R) (Nomos) was investigated in combination with the Siemens KD2 Linac. Results: In the comparison of calculated to measured dose, problems were encountered for the combination of KonRad and Elekta MLC as well as for the Peacock system. Multi-Access failed to assign the collimator angle correctly for plans with multiple collimator angles per beam. Communication problems of Multi-Access with both Linacs were observed, resulting in incorrect recording of the treatment. All reported issues were addressed by the manufacturers. Conclusion: For the commissioning of IMRT systems, the whole chain from the TPS to the Linac has to be investigated. Components that passed the commissioning in another clinical environment can have severe malfunctions when used in a new environment. Therefore, not only single components but the whole chain from planning to delivery has to be evaluated in commissioning and checked regularly for QA. 
650 4 |a collimator 
650 4 |a commissioning 
650 4 |a delivery 
650 4 |a dose-calculation algorithm 
650 4 |a dosimetry 
650 4 |a intensity-modulated radiation therapy (IMRT) 
650 4 |a optimization 
650 4 |a prostate-cancer 
650 4 |a quality assurance 
650 4 |a radiotherapy 
650 4 |a system combination 
650 4 |a tomotherapy 
650 4 |a verification 
700 1 |a Lorenz, Friedlieb  |d 1979-  |e VerfasserIn  |0 (DE-588)134100441  |0 (DE-627)692088091  |0 (DE-576)300312539  |4 aut 
700 1 |a Wertz, Hansjörg  |d 1976-  |e VerfasserIn  |0 (DE-588)143861247  |0 (DE-627)70462401X  |0 (DE-576)339135778  |4 aut 
700 1 |a Polednik, Martin  |d 1972-  |e VerfasserIn  |0 (DE-588)14139028X  |0 (DE-627)703967053  |0 (DE-576)323549853  |4 aut 
700 1 |a Wolff, Dirk  |d 1967-  |e VerfasserIn  |0 (DE-588)143387901  |0 (DE-627)645143472  |0 (DE-576)336799934  |4 aut 
700 1 |a Steil, Volker  |d 1957-  |e VerfasserIn  |0 (DE-588)1048197352  |0 (DE-627)779967224  |0 (DE-576)402012747  |4 aut 
700 1 |a Lohr, Frank  |e VerfasserIn  |0 (DE-588)1025307194  |0 (DE-627)72201967X  |0 (DE-576)37018694X  |4 aut 
700 1 |a Wenz, Frederik  |d 1966-  |e VerfasserIn  |0 (DE-588)113310390  |0 (DE-627)663837766  |0 (DE-576)346656281  |4 aut 
773 0 8 |i Enthalten in  |t Strahlentherapie und Onkologie  |d Berlin : Springer Medizin, 1997  |g 182(2006), 8, Seite 481-488  |h Online-Ressource  |w (DE-627)312407866  |w (DE-600)2003907-4  |w (DE-576)090884809  |x 1439-099X  |7 nnas  |a Intensity-modulated radiation therapy (IMRT) with different combinations of treatment-planning systems and linacs issues and how to detect them 
773 1 8 |g volume:182  |g year:2006  |g number:8  |g pages:481-488  |g extent:8  |a Intensity-modulated radiation therapy (IMRT) with different combinations of treatment-planning systems and linacs issues and how to detect them 
856 4 0 |u https://doi.org/10.1007/s00066-006-1544-6  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20220301 
993 |a Article 
994 |a 2006 
998 |g 113310390  |a Wenz, Frederik  |m 113310390:Wenz, Frederik  |d 60000  |d 63000  |d 60000  |e 60000PW113310390  |e 63000PW113310390  |e 60000PW113310390  |k 0/60000/  |k 1/60000/63000/  |k 0/60000/  |p 8  |y j 
998 |g 1025307194  |a Lohr, Frank  |m 1025307194:Lohr, Frank  |d 60000  |e 60000PL1025307194  |k 0/60000/  |p 7 
998 |g 1048197352  |a Steil, Volker  |m 1048197352:Steil, Volker  |d 60000  |d 63000  |e 60000PS1048197352  |e 63000PS1048197352  |k 0/60000/  |k 1/60000/63000/  |p 6 
998 |g 143387901  |a Wolff, Dirk  |m 143387901:Wolff, Dirk  |d 60000  |e 60000PW143387901  |k 0/60000/  |p 5 
998 |g 14139028X  |a Polednik, Martin  |m 14139028X:Polednik, Martin  |d 60000  |d 63000  |e 60000PP14139028X  |e 63000PP14139028X  |k 0/60000/  |k 1/60000/63000/  |p 4 
998 |g 143861247  |a Wertz, Hansjörg  |m 143861247:Wertz, Hansjörg  |d 60000  |e 60000PW143861247  |k 0/60000/  |p 3 
998 |g 134100441  |a Lorenz, Friedlieb  |m 134100441:Lorenz, Friedlieb  |d 130000  |e 130000PL134100441  |k 0/130000/  |p 2 
998 |g 1253242364  |a Dobler, Barbara  |m 1253242364:Dobler, Barbara  |d 60000  |d 63000  |e 60000PD1253242364  |e 63000PD1253242364  |k 0/60000/  |k 1/60000/63000/  |p 1  |x j 
999 |a KXP-PPN1794160272  |e 4076438124 
BIB |a Y 
SER |a journal 
JSO |a {"name":{"displayForm":["Barbara Dobler, Friedlieb Lorenz, Hansjörg Wertz, Martin Polednik, Dirk Wolff, Volker Steil, Frank Lohr, Frederik Wenz"]},"physDesc":[{"extent":"8 S."}],"recId":"1794160272","relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"recId":"312407866","pubHistory":["Nachgewiesen 173.1997 -"],"id":{"issn":["1439-099X"],"eki":["312407866"],"zdb":["2003907-4"]},"disp":"Intensity-modulated radiation therapy (IMRT) with different combinations of treatment-planning systems and linacs issues and how to detect themStrahlentherapie und Onkologie","part":{"issue":"8","year":"2006","pages":"481-488","text":"182(2006), 8, Seite 481-488","extent":"8","volume":"182"},"note":["Gesehen am 13.05.09"],"type":{"bibl":"periodical","media":"Online-Ressource"},"origin":[{"publisher":"Springer Medizin ; Urban & Vogel","dateIssuedKey":"1997","dateIssuedDisp":"1997-","publisherPlace":"Berlin ; Heidelberg ; [München]"}],"title":[{"title":"Strahlentherapie und Onkologie","subtitle":"journal of radiation oncology, biology, physics","title_sort":"Strahlentherapie und Onkologie"}],"language":["ger"]}],"id":{"eki":["1794160272"],"doi":["10.1007/s00066-006-1544-6"]},"person":[{"family":"Dobler","display":"Dobler, Barbara","given":"Barbara","role":"aut"},{"role":"aut","given":"Friedlieb","family":"Lorenz","display":"Lorenz, Friedlieb"},{"display":"Wertz, Hansjörg","family":"Wertz","role":"aut","given":"Hansjörg"},{"family":"Polednik","display":"Polednik, Martin","role":"aut","given":"Martin"},{"given":"Dirk","role":"aut","family":"Wolff","display":"Wolff, Dirk"},{"role":"aut","given":"Volker","display":"Steil, Volker","family":"Steil"},{"display":"Lohr, Frank","family":"Lohr","role":"aut","given":"Frank"},{"display":"Wenz, Frederik","family":"Wenz","role":"aut","given":"Frederik"}],"note":["Gesehen am 01.03.2022"],"origin":[{"dateIssuedDisp":"1 August 2006","dateIssuedKey":"2006"}],"title":[{"title":"Intensity-modulated radiation therapy (IMRT) with different combinations of treatment-planning systems and linacs","title_sort":"Intensity-modulated radiation therapy (IMRT) with different combinations of treatment-planning systems and linacs","subtitle":"issues and how to detect them"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"]} 
SRT |a DOBLERBARBINTENSITYM1200